hit counter script

IBM SAN384B Installation, Service And User Manual page 80

System storage
Table of Contents

Advertisement

Table 9. Port and routing blade LED descriptions (continued)
LED purpose
Status LED FCPort Status
|
|
|
|
|
|
|
|
|
52
SAN384B Installation, Service, and User Guide
Color
No light (LED is off)
Steady amber
Slow-flashing amber (on 2
seconds, then off 2 seconds)
Fast-flashing amber (on 1/2
second, then off 1/2 second)
No light (LED is off)
Steady green
Slow-flashing green (on 1
second, then off 1 second)
Fast-flashing green (on 1/4
second, then off 1/4 second
Flickering green
Steady amber
Slow-flashing amber (on 2
seconds, then off 2 seconds)
Fast-flashing amber (on 1/2
second, then off 1/2 second)
Alternating green/amber
Green, amber, off (cycle is
about 1 second)
Amber, amber, pause (cycle is
about 1 second)
Status
Blade is either healthy or does
not have power.
Blade is faulty.
Blade is not seated correctly or
is faulty.
Environmental range exceeded. Check for out-of-bounds
Port has no incoming power,
or there is no light or signal
carrier detected.
Polling is in progress.
Connected device is configured
in an offline state.
Port is online (connected to an
external device) but has no
traffic.
Port is online but segmented,
indicating a loopback plug or
cable or an incompatible
switch.
Port is in internal loopback
(diagnostic).
Port is online, with traffic
flowing through port.
Port is receiving light or signal
carrier, but it is not online yet.
Port is disabled due to
diagnostic tests or portDisable
or portCfgPersistentEnable
command.
Transceiver or port is faulty.
Port is bypassed
Beaconing initiated on the local
switch.
Beaconing initiated on the
HBA and reflected on the port.
Recommended Action
Verify that the power LED is
on.
Ensure blade is firmly seated
and check the status with the
slotShow command.Blade may
not be compatible with other
blades in the chassis. See
"FCOE10-24 blade" on page
129 for limitations. If the LED
remains amber, contact IBM.
Pull blade out and reseat it. If
the LED continues to flash,
replace the blade.
environmental condition and
correct it.
Verify that the power LED is
on, check the transceiver and
cable.
Allow 60 seconds for polling to
complete.
Verify the status of the
connected device.
No action required.
Verify that the correct device is
attached to the SAN384B.
No action required.
No action required.
Reset the port from the
workstation using the
portEnable or
portCfgPersistentEnable
command.
Reset the port from the
workstation using the
portEnable or
portCfgPersistentEnable
command.
Change the transceiver or reset
the switch from the
workstation.
Reset the port from the
workstation using the
portEnable or
portCfgPersistentEnable
command.
No action required. Beaconing
used to locate/identify port.
No action required. Beaconing
used to locate/identify port.

Advertisement

Table of Contents
loading

Table of Contents