Installation
Fixing Installation Plate
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a con-
crete wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for piping
connections must be done safely.
CHASSIS
(Grade)
A
SZ
35
(7k~9k)
SU
92
(11k~14k)
S3
58
(18k~26k)
• For S3 chassis, the center of the unit is different
from that of the Installation plate.
Drill a Hole in the Wall
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
14 Room Air Conditioner
Distance (mm)
B
C
D
33
156
33
44
67
44
3
292
3
Installation Plate
Type "A" screw
(SU)
C
Installation plate
Ø70mm
Left rear piping
(SZ)
Installation plate
C
Left rear piping
(S3)
Installation plate
C
WALL
Indoor
A
Ø70mm
Right rear piping
A
Right rear piping
A
Right rear piping
Outdoor