hit counter script
Toshiba RAS-M10SMUV-E Installation Manual
Toshiba RAS-M10SMUV-E Installation Manual

Toshiba RAS-M10SMUV-E Installation Manual

4-way air discharge cassette type
Hide thumbs Also See for RAS-M10SMUV-E:

Advertisement

AIR CONDITIONER
CLIMATISEUR
(TYPE SPLIT)
KLIMAGERÄT
(SPLIT-TYP)
CONDIZIONATORE D'ARIA
AIRE ACONDICIONADO
ÊËÉÌÁÔÉÓÔÉÊÏ
AR CONDICIONADO
LUFTKONDITIONERINGSAPPARAT
<4-Way Air Discharge Cassette Type>
<Type cassette à 4 voies de soufflage>
<4-Wege-Belüftungskassette>
<Tipo a cassetta con scarico d'aria a 4 vie>
<Modelo de casete de distribución de aire de 4 vías>
<ÅêñïÞ áÝñá 4-Äéåõèýíóåùí Ôýðïõ ÊáóÝôáò>
<Descarga de ar tipo cassete de 4 vias>
<Apparat med 4-vägars luftutsläpp>
Indoor Unit
Unité intérieure/Raumeinheit/Unità interna/Unidad interior
ÅóùôåñéêÞ ÌïíÜäá/Unidade interior/
Heat Pump Model
Modèle à thermopompe
Geräte mit Heizung
Modello con pompa di riscaldamento
Modelo con bomba de calor
ÌïíôÝëï ìå Áíôëßá Èåñìüôçôáò
Modelo de bomba térmica
Värmepumpsmodell
RAS-M10SMUV-E
RAS-M13SMUV-E
RAS-M16SMUV-E
G-INSTALLATIONS-HANDBUCH
MANUALE DI INSTALLAZIONE
ÅÃ×ÅÉÑÉÄÉÏ ÅÃÊÁÔÁÓÔÁÓÇÓ
(SPLIT TYPE)
(TIPO SPLIT)
(TIPO SPLIT)
(ÄÉÁÉÑÏÕÌÅÍÏÕ ÔÕÐÏÕ)
(TIPO SPLIT)
Cooling Only Model
Modèle à froid seul
Geräte nur zur Kühlung
Modello solo per raffreddamento
Modelo de refrigeración únicamente
ÌïíôÝëï Øýîçò áðïêëåéóôéêÜ
Modelo Apenas para Refrigeração
Modell endast för avkylning
RAS-M10SMUCV-E RB-B11MC(W)E
RAS-M13SMUCV-E
RAS-M16SMUCV-E
INSTALLATION MANUAL
MANUEL D'INSTALLATION
MANUAL DE INSTALACIÓN
MANUAL DE INSTALAÇÃO
INSTALLATIONSHANDBO
Not accessible to the general public
Vente interdite au grand public
Kein öffentlicher Zugang
Non accessibile a clienti generici
No destinado al público en general
Ìç ðñïóâÜóéìï áðü ôï ãåíéêü êïéíü
Não acessível ao público em geral
Inte tillgänglig för allmänheten
(SPLIT TYP)
/Inomhusenhet

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAS-M10SMUV-E

  • Page 1 Modello solo per raffreddamento Modelo con bomba de calor Modelo de refrigeración únicamente ÌïíôÝëï ìå Áíôëßá Èåñìüôçôáò ÌïíôÝëï Øýîçò áðïêëåéóôéêÜ Modelo de bomba térmica Modelo Apenas para Refrigeração Värmepumpsmodell Modell endast för avkylning RAS-M10SMUV-E RAS-M10SMUCV-E RB-B11MC(W)E RAS-M13SMUV-E RAS-M13SMUCV-E RAS-M16SMUV-E RAS-M16SMUCV-E...
  • Page 2 Please read this Installation Manual carefully before installing ADOPTION OF NEW REFRIGERANT the Air Conditioner. This Air Conditioner is a new type which adopts the • This Manual describes the installation method of the indoor new refrigerant HFC (R410A) instead of the conven- unit.
  • Page 3: Table Of Contents

    CONTENTS Accessory parts and Parts to be procured locally ...... 1 EVACUATING ................ 14 PRECAUTIONS FOR SAFETY ..........2 ELECTRICAL WORK ............15 SELECTION OF INSTALLATION PLACE ......4 APPLICABLE CONTROLS ........... 18 INSTALLATION OF INDOOR UNIT ........6 TEST OPERATION ..............20 DRAIN PIPING WORK ............
  • Page 4: Accessory Parts And Parts To Be Procured Locally

    Connecting pipe (Gas side) Thermal insulation for refrigerant pipe (10 mm or more, thermal insulating foam polyethylene) (9.5 mm (diam.), Nominal (diam.) 3/8” thick 0.8 mm) RAS-M10SMUV-E, RAS-M10SMUCV-E, Thermal insulation for drain pipe RAS-M13SMUV-E, RAS-M13SMUCV-E (10 mm or more, foam polyethylene) (12.7 mm (diam.), Nominal (diam.) 1/2”...
  • Page 5: Precautions For Safety

    PRECAUTIONS FOR SAFETY • Ensure that all Local, National and International regulations are satisfied. • Read this “PRECAUTIONS FOR SAFETY” carefully before Installation. • The precautions described below include the important items regarding safety. Observe them without fail. • After the installation work, perform a trial operation to check for any problem. Follow the Owner’s Manual to explain how to use and maintain the unit to the customer.
  • Page 6 PRECAUTIONS FOR SAFETY • After unpacking the unit, examine for possible damage. • Do not install in a place that might increase the vibration of the unit. • To avoid personal injury (with sharp edges), be careful when handling parts. •...
  • Page 7: Selection Of Installation Place

    SELECTION OF INSTALLATION PLACE WARNING • The air conditioner must be installed in a location that can support the weight of the unit effectively. If the unit is not installed on a foundation that can support its weight effectively, the unit may fall down, resulting in possible human injury.
  • Page 8 : 23°C or more) may generate dew inside When changing the setting of the ceiling height in the the ceiling. models, RAS-M10SMUV-E, M10SMUCV-E, M13SMUV-E and M13SMUCV-E, if it is set over 1. Unit is installed inside the ceiling with slated roof.
  • Page 9: Installation Of Indoor Unit

    WARNING Install the air conditioner certainly to sufficiently withstand the weight. If the strength is insufficient, the unit may fall down resulting in human injury. Perform a specified installation work to guard against an earthquake. An incomplete installation can cause accidents by the units falling and dropping. Remote controller •...
  • Page 10 For branch duct knockout For branch duct square hole 150 (diam.) knockout square 575 Unit external dimension 139.5 hole 150 (diam.) 190.5 Refrigerant pipe (Gas) 9.5 (diam.) (RAS-M10SMUV-E, M13SMUV-E, Bottom face of ceiling M10SMUCV-E, M13SMUCV-E) (Gas) 12.7 (diam.) (RAS-M16SMUV-E, M16SMUCV-E)
  • Page 11 Ceiling opening and installation of hanging bolts • Evaluate and determine the piping and wiring requirements inside the ceiling prior to the hanging of the unit. • After installation place of the indoor unit has been determined, create opening in ceiling and install the hanging bolts.
  • Page 12 INSTALLATION OF INDOOR UNIT Installation of indoor unit • Attach the nut (M10 or W3/8: Procured locally) and washer Hanging bolt (34 mm (diam.)) to the hanging bolt. M10 flat washer (W3/8 or M10) (Accessory) • Put washers at either side of the T-groove on the hanging bracket of the indoor unit in order to hang the unit.
  • Page 13: Drain Piping Work

    DRAIN PIPING WORK CAUTION Pipe material / Insulator and size The following materials for piping work and insulation • Install the drain piping so that the water are to be procured locally. drains effectively. Hard vinyl chloride pipe socket for VP25 •...
  • Page 14 DRAIN PIPING WORK Connection of drain pipe Check the draining • Connect the hard socket (Procured locally) to the After completion of drain piping, hard socket side of the supplied flexible hose which Check water drains away and that no water leaks has been installed.
  • Page 15 Thermal insulating process • After checking the draining, wrap the supplied thermal insulation material for the drain connecting part around the flexible hose leaving no clearance from the root of the drain pipe connecting port of the indoor unit. • Wrap the thermal insulation material (procured locally) around the drain pipe so that it piles up on the supplied the thermal insulation material for the drain connecting part, leaving no clearance.
  • Page 16: Refrigerant Piping And Evacuating

    REFRIGERANT PIPING AND EVACUATING • Flaring diam. meter size : Refrigerant piping A (Unit : mm) 1. If the outdoor units are to be mounted on a wall, make sure that the supporting platform is sufficiently strong. The platform should be - 0.4 designed and manufactured to maintain its Outer diam.
  • Page 17 EVACUATING Packed valve handling precautions AIR PURGE • Open the valve stem until it touches the stopper. Evacuate the air in the connecting pipes and in the indoor unit using vacuum pump. Once it is in contact with the stopper, refrain from applying any more force than is necessary.
  • Page 18: Electrical Work

    ELECTRICAL WORK WARNING 1. Using the specified wires, ensure to connect the wires, and fix wires securely so that the external tension to the wires do not affect the connecting part of the terminals. Incomplete connection or fixation may cause a fire, etc. 2.
  • Page 19 Wire connection REQUIREMENT • Be sure to connect the wires matching the terminal numbers. Incorrect connection causes a trouble. • Be sure to pass the cables through the bushing of wiring connection port of the indoor unit. • Keep a margin (Approx. 100mm) on a wire to hang down the electric parts box at servicing, etc. •...
  • Page 20 ELECTRICAL WORK Wiring Wiring diagram 1. Remove a screw and then remove cover of the electric parts box. 2. Strip wire ends (10 mm). Indoor side 3. Match wire colors with terminal numbers on indoor and outdoor units’ terminal blocks and firmly screw wires to the corresponding terminals.
  • Page 21: Applicable Controls

    APPLICABLE CONTROLS Remote controller selector switch setting • If two indoor units are installed in the same room or adjoining rooms, when the user tries to operate only one unit, both units may receive the same remote controller signal and operate. This can be prevented by changing one of the indoor units and remote controllers to setting “B”...
  • Page 22 APPLICABLE CONTROLS To improve Cooling/Heating effect When only poor cooling/heating effect is obtained due to installation place of the indoor unit or construction of the room, the detection temperature of cooling/heating can be changed. • Remove the cover of the electric parts box by taking off the mounting screws (3 positions) and pushing the hooking section.
  • Page 23: Test Operation

    TEST OPERATION Test operation Check and Test operation • To test the system, push and hold RESET button for Be sure to test the piping connections for gas leak. 10 sec. (There will be one short beep.) • Check the flare nut connections, valve stem cap connections and service port cap connections for gas leak with a leak detector or soap water.
  • Page 24: Maintenance

    MAINTENANCE Prior to maintenance, ensure the power supply is turned off. WARNING CAUTION Cleaning of the air filter and other parts of the air filter Do not handle the buttons with wet hands involves dangerous work in high places, so be sure to as this will cause the risk of electric shock.

Table of Contents