SPECIFICATIONS Output connector General AC-L10A/B/C System NP-FM50 battery pack AC power adaptor A/V OUT (Monaural) Used battery pack Image device Used battery Minijack 8.98 mm (1/1.8 type) NP-FM50 Power requirements Lithium ion ba ttery Video: 1 Vp-p, 75 Ω color CCD Power requirements 100 to 240 V AC, 50/60 Hz Maximum voltage...
Ver. 1.1 2001. 08 TABLE OF CONTENTS Section Title Page ADJUSTMENTS 5-1. Camera Section Adjustment ..........4 1-2. Initialization of B, D, E, F, 7, 9 Page Data ......4 1-2-1. Initialization of D Page Data ........4 1. Initializing D Page Data ..........4 1-2-2.
DSC-S85 Ver. 1.1 2001. 08 SECTION 5 ADJUSTMENTS 5-1. CAMERA SECTION ADJUSTMENT 1-2. INITIALIZATION OF B, D, E, F, 7, 9 PAGE DATA 5. F Page Table Note 1: Fixed data-1: Initialized data. 1-2-1. Initialization of D Page Data (Refer to “1.Initializing of B, E, F, 7, 9 Page Data”) 1.
Page 5
Ver. 1.1 2001. 08 Address Initial value Remark Address Initial value Remark 49 to 4C Fixed data-1 (Initialized data) Strobe white balance adj. 4F to 58 Fixed data-1 (Initialized data) Auto white balance standard data input Mechanical shutter adj. Fixed data-1 (Initialized data) Flange back adj.
Ver. 1.1 2001. 08 1-4. CAMERA SYSTEM ADJUSTMENTS Before perform the camera system adjustments, check that the specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat- isfied. Note: For “CAMERA SYSTEM ADJUSTMENTS”, perform in order of item numbers. Data setting during camera system adjustments Perform the following data setting before the camera system ad- justments.
1. Flange Back Adjustment (Using the minipattern box) Specified voltage: The specified voltage varies according to the The flange back of inner focus lens is adjusted automatically. If minipattern box, so adjustment the power sup- shifted, the auto focus is disordered. ply output voltage to the specified voltage writ- ten on the sheet which is supplied with the mini- Mode...
2. Flange Back Adjustment Adjusting method: (Using the flange back adjustment chart) Order Page Address Data Procedure The flange back of inner focus lens is adjusted automatically. If shifted, the auto focus is disordered. Perform “Data setting during Mode CAMERA camera system adjustments”.
3. Flange Back Check Mode CAMERA Subject Siemens star chart (1.0 m from the front of the lens) (Luminance: 200 to 400 lux) Measurement Point Check operation on the LCD screen Measuring Instrument Specified value Focused at the TELE end and WIDE end Checking method: Order Page Address Data...
4. Picture Frame Setting How to reset the zoom and focus when they deviated: Order Page Address Data Procedure Mode CAMERA Subject Color bar chart (Color reproduction adjustment frame with the zoom lens at WIDE end) (Note 2) Measurement Point Video terminal of A/V OUT jack (Note 2) (75 Ω...
5. F No. Standard Data Input 6. Mechanical Shutter Adjustment Compensate the unevenness of the iris meter sensitivity. Adjust the period which the mechanical shutter is closed, and com- pensate the exposure. Mode CAMERA Mode CAMERA Subject Clear chart (Color reproduction adjustment Subject Clear chart frame with the zoom lens at WIDE...
Ver. 1.1 2001. 08 7. Light Level Adjustment 8. Mixed Color Cancel Adjustment Adjust the standard LV value. To perform mixed color cancel adjustment based on data of each color in color bar. Mode CAMERA Mode CAMERA Subject Clear chart (Color reproduction adjustment Subject Color bar chart...
9. Auto White Balance Standard Data Input Adjust the white balance standard data at 3200K. Mode CAMERA Subject Clear chart (Color reproduction adjustment frame with the zoom lens at WIDE end) Adjustment Page Adjustment Address 3A to 3D, 59 Note 1: Check that the data of page: 6, address: 02 is “00”. If not, turn the power of unit OFF/ON.
Ver. 1.1 2001. 08 10. Auto White Balance Adjustment Order Page Address Data Procedure Adjust to the proper auto white balance output data. If it is not Check that the displayed data correct, auto white balance and color reproducibility will be poor. (Note 3) satisfies the R ratio specified Mode...
11. Smear Compensation Adjustment Adjust the smear compensation data from white balance standard data at 3200K. Mode CAMERA Subject Clear chart (Color reproduction adjustment frame with the zoom lens at WIDE end) Adjustment Page Adjustment Address 9D, 9E Note 1: Check that the data of page: 6, address: 02 is “00”. If not, turn the power of unit OFF/ON.
Ver. 1.1 2001. 08 12. Color Reproduction Adjustment Processing after Completing Adjustment: Adjust the color separation matrix coefficient so that proper color Order Page Address Data Procedure reproduction is produced. Press PAUSE button. Mode CAMERA Subject Color bar chart (Color reproduction adjustment frame with the zoom lens at Release the data setting WIDE end)
Ver. 1.1 2001. 08 13. Color Reproduction Check Processing after Completing Adjustment: Order Page Address Data Procedure Mode CAMERA Press PAUSE button. Subject Color bar chart (Color reproduction adjustment frame with the zoom lens at WIDE end) Measurement Point Video terminal of A/V OUT jack (75 Ω...
Ver. 1.1 2001. 08 14. Auto White Balance Check OUTDOOR luminance check Place the C14 filter on the Mode CAMERA lens. Subject Clear chart Note down the data. (Color reproduction adjustment frame with the zoom lens at Press PAUSE button. WIDE end) Press PAUSE button.
Ver. 1.1 2001. 08 15. CCD White Defect Compensation Mode CAMERA Subject Not required Measurement Point Displayed data of page: 6, address: 55 Measuring Instrument Adjusting remote commander Adjustment Page Adjustment Address 88 to A3 Note 1: Check that the data of page: 6, address: 02 is “00”. If not, turn the power of unit OFF/ON.
16. CCD Black Defect Compensation Processing after Completing Adjustment: Order Page Address Data Procedure Mode CAMERA Press PAUSE button. Subject Clear chart (Color reproduction adjustment frame) Measurement Point Displayed data of page: 6, address: 55 Set the data noted down at Measuring Instrument Adjusting remote commander step 3, and press PAUSE...
17. Strobe White Balance Adjustment Adjusting method: Adjust the white balance when the strobe light flashed. Order Page Address Data Procedure Mode CAMERA Perform “Data setting during Subject Flash adjustment box (Note 3) camera system adjustments”. (1.0 m from the front of the lens) (Refer to page 5-14) Adjustment Page Adjustment Address...