SERVICING NOTICES ON CHECKING 1. KEEP THE NOTICES 6. AVOID AN X-RAY As for the places which need special attentions, Safety is secured against an X-ray by consider- they are indicated with the labels or seals on the ing about the cathode-ray tube and the high cabinet, chassis and parts.
ABOUT LEAD FREE SOLDER (PbF) Distinction of PbF PCB: PCBs (manufactured) using lead free solder will have a PbF printing on the PCB. (Please refer to figures.) Caution: • Pb free solder has a higher melting point than standard solder; Typically the melting point is 50°F~70°F(30°C~40°C) higher.
TABLE OF CONTENTS SERVICING NOTICES ON CHECKING ..................A1-1 HOW TO ORDER PARTS ......................A1-1 IMPORTANT ..........................A1-1 ABOUT LEAD FREE SOLDER (PbF) ..................A1-2 TABLE OF CONTENTS ......................A2-1 A3-1~A3-5 GENERAL SPECIFICATIONS ....................DISASSEMBLY INSTRUCTIONS 1. REMOVAL OF ANODE CAP ....................B1-1 B2-1, B2-2 2.
GENERAL SPECIFICATIONS CRT Size / Visual Size 20 inch / 508.0mmV System CRT Type Normal Magnetic Field BV/BH +0.45G/0.18G Color System NTSC Speaker 2Speaker Position Front Size 2 x 4.7 Inch Impedance Sound Output 2.5+2.5 W 10%(Typical) NTSC3.58+4.43 /PAL60Hz Tuning Broadcasting System System M System...
Page 6
GENERAL SPECIFICATIONS On Screen Menu Display Menu Type Character Picture Contrast Brightness Color Tint Sharpness Audio Bass Treble Balance BBE On/Off Stable Sound On/Off Surround On/Off CH Set Up TV/CABLE(CATV) Auto CH Memory Add/ Delete Lock CH Lock Video Lock Game Timer Change Password On Timer...
Page 7
GENERAL SPECIFICATIONS G-10 Remote Unit RC-EH Control Glow in Dark Remocon Format Toshiba Remocon Format Toshiba Custom Code 40-BF h Power Source Voltage(D.C) UM size x pcs UM-4 x 2 pcs Total Keys Keys Keys Power CH Up CH Down...
Page 8
GENERAL SPECIFICATIONS G-11 Features Auto Degauss Auto Shut Off Canal+ Cable Anti-theft Rental Memory(Last CH) Memory(Last Volume) V-Chip Type -- Type Auto Search CH Allocation Just Clock Function CH Label VM Circuit Full OSD Premiere Comb Filter Lines Auto CH Memory Hotel Lock Closed Caption Stable Sound...
Page 9
Height (cm) 60 (ORION SPEC:46) Container Stuffing Sets/40' container G-17 Cabinet Material Cabinet Cabinet Front PS 94V0 DECABROM Cabinet Rear PS 94V0 DECABROM Non-Halogen Demand Eyelet Demand G-18 Environment Environmental standard requirement (by buyer) Green procurement of TOSHIBA Pb-free Phase3(Ph A3-5...
DISASSEMBLY INSTRUCTIONS 3. After one side is removed, pull in the opposite direction to 1. REMOVAL OF ANODE CAP remove the other. Read the following NOTED items before starting work. NOTE After turning the power off there might still be a potential Take care not to damage the Rubber Cap.
DISASSEMBLY INSTRUCTIONS When IC starts moving back and forth easily after REMOVAL AND INSTALLATION OF desoldering completely, pickup the corner of the IC using a FLAT PACKAGE IC tweezers and remove the IC by moving with the IC desoldering machine. (Refer to Fig. 2-3.) REMOVAL NOTE Put Masking Tape (cotton tape) around the Flat Package...
Page 12
DISASSEMBLY INSTRUCTIONS INSTALLATION When bridge-soldering between terminals and/or the soldering amount are not enough, resolder using a Thin-tip Take care of the polarity of new IC and then install the new Soldering Iron. (Refer to Fig. 2-8.) IC fitting on the printed circuit pattern. Then solder each lead on the diagonal positions of IC temporarily.
SERVICE MODE LIST This unit is provided with the following SERVICE MODES so you can repair, examine and adjust easily. To enter the Service Mode, press both set key and remote control key for more than 2 seconds. Remocon Key Operations Set Key Releasing of V-CHIP PASSWORD.
ELECTRICAL ADJUSTMENTS 1. ADJUSTMENT PROCEDURE 2. BASIC ADJUSTMENTS Read and perform these adjustments when repairing the 2-1: CONSTANT VOLTAGE circuits or replacing electrical parts or PCB assemblies. Place the set in AV MODE without signal. CAUTION Connect the digital voltmeter to the TP401. Adjust the VR502 until the digital voltmeter is 113 ±...
Page 15
ELECTRICAL ADJUSTMENTS 2-6: VERTICAL SIZE 2-12: OSD POSITION Receive the monoscope pattern. Activate the adjustment mode display of Fig. 1-1. Using the remote control, set the brightness and contrast Press the VOL. UP/DOWN button on the remote to normal position. control until the difference of A and B becomes Activate the adjustment mode display of Fig.
Page 16
ELECTRICAL ADJUSTMENTS 100% white 100% Fig. 2-3 2-15: TINT Receive the color bar pattern. (RF Input) Using the remote control, set the brightness, contrast, color and tint to normal position. Connect the oscilloscope to TP024. Activate the adjustment mode display of Fig. 1-1 and press the channel button (22) on the remote control to select "TINT".
ELECTRICAL ADJUSTMENTS 3-3: STATIC CONVERGENCE 3. PURITY AND CONVERGENCE ADJUSTMENTS NOTE Adjust after performing adjustments in section 3-2. NOTE Receive the crosshatch pattern from the color bar Turn the unit on and let it warm up for at least 30 generator.