hit counter script

Mechanical Adjustment; Electrical Adjustment - Sony WM-FX141 Service Manual

Radio cassette player sony wm-fx141
Hide thumbs Also See for WM-FX141:
Table of Contents

Advertisement

3-1.
MECHANICAL ADJUSTMENTS
Precaution
1. Clean the following parts with a denatured-alcohol-moistend
swab :
playback head
capstan
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be perfomed with the rated power supply
voltage (2.5V) unless otherwise noted.
Torque Measurement
Mode
Torque meter
FWD
CQ-102C
FWD
Back Tension
FF, REW
CQ-201B
SECTION 3
ADJUSTMENTS
pinch roller
rubber belts
Meter reading
20 to 42 g•cm
(0.28 to 0.58 oz•inch)
less than 2 g•cm
(less than 0.03 oz•inch)
more than 60 g•cm
(more than 0.83 oz•inch)
3-2.
ELECTRICAL ADJUSTMENTS
Precaution
• Supplied voltage : 2.5V
• Switch and control position
TAPE switch : NORM
VOLUME control : maximum
AVLS switch : OFF
TAPE SECTION
• FUNCTION switch : TAPE
Test tape
Type
WS-48A
Tape speed adjustment
Tape selection adjustment : NORM
Procedure :
test tape
WS-48A
(3kHz, 0dB)
set
Adjustment Value: normal tape speed
Adjust the tape speed adjustment RV601, so that the freqency counter
reading becomes 3,000Hz.
Specification Value:
Digital frequency counter
2,945 to 3,015Hz
Frequency difference between the beginning and the end of the tape
should be within 1.5% (45Hz).
Adjustment Location :
— 6 —
Signal
Used for
3kHz, 0dB
Tape Speed Adjustment
frequency
counter
16 Ω
J302(phones)
0dB=0.775V

Advertisement

Table of Contents
loading

Table of Contents