Table 2. Firmware Checkpoints (continued)
Checkpoint
E5FE
E600
E601
E602
E603
E604
E605
E60E
E60F
E6FF
E700
E701
E702
E703
E704
E705
E706
E707
E708
Description
Get the system's licensed memory quantity
from the service processor
SSA PCI adapter open firmware has run
successfully.
SSA PCI adapter BIST has started but
failed to complete after 4 seconds.
SSA PCI open firmware has started.
SSA PCI adapter BIST has completed with
an error.
SSA PCI adapter BIST and subsequent
POSTs have completed successfully.
SSA PCI adapter BIST has completed
successfully but subsequent POSTS have
failed.
SSA PCI open firmware about to exit (no
stack corruption).
SSA PCI open firmware has run
unsuccessfully.
SSA PCI open firmware about to exit (with
stack corruption).
Create system firmware VPD
Create memory VPD.
Create processor card VPD.
Create operator panel VPD.
Create CEC VPD.
Create VPD.
Create VPD.
Create system VPD.
Create VPD.
Action/
Possible Failing FRU
1. Replace the I/O drawer subsystem
backplane specified by the location
code.
2. Power down, then power up the
system.
3. Call service support.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
System firmware may be corrupted.
Reinstall system firmware.
1. Check for system firmware updates.
2. Call for support.
1. Check for system firmware updates.
2. Call for support.
1. Check for system firmware updates.
2. Call for support.
1. Check for system firmware updates.
2. Call for support.
1. Check for system firmware updates.
2. Call for support.
1. Check for system firmware updates.
2. Call for support.
1. Check for system firmware updates.
2. Call for support.
Go to "MAP 1540: Problem Isolation
Procedures" on page 110.
Chapter 4. Checkpoints
151