3-4. TG7 Support
1.
Removal procedure
Remove the screw (special head screw M1.4 × 6.0) 1.
1)
2)
Remove the FP-468 flexible board 2 from the dowel A of
the TG7 support.
3)
Remove the FP-468 flexible board 2 from the groove B of
the TG7 support.
4)
Remove the TG7 support 3 in the direction of the arrow.
Groove B
Screw
1
(M1.4 × 6.0)
2 FP-468 flexible board
Dowel A
Round hole
Remove in the direction
of the arrow.
DV MECHANICAL ADJUSTMENT MANUAL VII
2.
Attachment procedure
1)
Install the FP-468 flexible board 2 into the groove B of TG7
support 3.
2)
Insert the claw C of the TG7 support 3 into the groove D of
the capstan block, and fix it while aligning with the dowel E.
3)
Align the round hole of the FP-468 flexible board 2 with the
dowel A of the TG7 support 3.
Install the screw (special head screw M1.4 × 6.0) 1.
4)
Tightening torque: 0.059 ± 0.01N•m (0.6 ± 0.1kgf•cm)
Points to be noted
• Be careful not to damage the FP-468 flexible board.
— 15 —
3 TG7 support
Groove B
Claw C
Round hole
Capstan block
Dowel E
Groove D