Sign In
Upload
Manuals
Brands
Hitachi Manuals
Server
USP VM
Hitachi USP VM Enterprise Storage System Manuals
Manuals and User Guides for Hitachi USP VM Enterprise Storage System. We have
2
Hitachi USP VM Enterprise Storage System manuals available for free PDF download: User And Reference Manual, Configuration Manual
Hitachi USP VM User And Reference Manual (531 pages)
Command Control Interface guide
Brand:
Hitachi
| Category:
Server
| Size: 8.72 MB
Table of Contents
Intended Audience
12
Release Notes
12
Referenced Documents
13
Document Conventions
14
Getting Help
17
Overview
19
About Command Control Interface
20
Provisioning Functions
21
Command Execution Modes
22
Command Execution by the In-Band and Out-Of-Band Methods
23
User Authentication Mode
26
Resource Group Function
27
Data Protection
28
CCI Software Environment
29
Overview of the CCI Software Environment
30
Command Device Guarding
31
Alternate Command Device Function
33
Remote Command Device
34
CCI and the SCSI Command Interface
35
Command Competition
36
Issuing Commands for Ldevs Within a LUSE Device
37
CCI Instance Configurations
38
Host Machines that Can be Paired
40
Configuration Definition File
41
Configuration Definition File Settings
44
Horcm_Mon
45
HORCM_CMD (Out-Of-Band Method)
49
Horcm_Dev
51
Horcm_Inst
53
Horcm_Ldev
54
Horcm_Ldevg
55
Horcm_Instp
56
Correspondence of Configuration File and Mirror Descriptors
57
Cascading Connection and Configuration Files
58
Shadowimage
59
Cascading Connections for Truecopy and Shadowimage
61
CCI Software Files
63
CCI Files Supplied with the Software
64
CCI Files for Windows-Based Systems
65
CCI Files for Openvms-Based Systems
67
CCI Log and Trace Files
68
CCI Trace Files
71
Logging Raidcom Command
74
User-Created Files
77
CCI Functions
79
System Configuration Using CCI
80
Method Using the Out-Of-Band Method
83
Hardware Requirements
84
Security Setting
84
User Authentication
86
Command Operation Authority and User Authentication
87
Controlling User Resources
88
Commands Executed Depending on Operation Authorities
91
Relation between Resource Groups and Command Operations
99
Resource Lock Function
102
Context Check
104
How to Check
105
Configuration Check
111
Resource Location and Parameter
112
LDEV Grouping Function
113
Device Group Definition Methods
116
Define Device Group
117
Device Group Creation
118
LDEV Addition to Device Group
119
Device Group Deletion
120
Copy Group Function
121
Copy Group Creation
123
LDEV Deletion from Copy Group
124
Copy Group Deletion
125
Pair Operations with Mainframe Volumes
127
Pair Status and Access Permission for Mainframe Ldevs
128
Operational Differences for Multiplatform Volumes
130
Operational Differences for Replication Commands
131
Global Storage Virtualization Function
132
Using CCI with the Global Storage Virtualization Function
133
Machine by HORCM_CMD
135
Specifying a Virtual Storage Machine to HORCM_VCMD
137
Operation Target for Raidcom Commands When Specifying the Virtual Storage Machine in HORCM_VCMD
139
Horcm_Cmd
146
Starting up CCI
147
Starting up on UNIX Systems
148
Starting up on Windows Systems
149
Starting up on Openvms Systems
150
Starting CCI as a Service (Windows Systems)
152
Provisioning Operations with CCI
155
About Provisioning Operations
156
Synchronous Command Processing
157
Workflow for Executing Asynchronous Commands
158
Help on Configuration Setting Commands
160
Provisioning Operations that Can be Performed on Device Groups
167
Operation Method
168
Workflow for Performing Provisioning Operations
169
Resource Group Operations
170
Allocating Resources to Other Resource Groups
171
Execution Example
172
Script Examples (Open Systems)
174
Creating Internal Volumes (Mainframe Volume)
176
Script Examples
177
Script Examples
179
Virtual Volume (Dynamic Provisioning) Operations
180
Script Examples
182
Raidcom Delete Ldev Command to Delete a Virtual Volume
185
Volume
186
Virtual Volume (Dynamic Provisioning for Mainframe) Operations
187
Script Examples
188
Virtual Volume (Dynamic Tiering) Operations
190
Creating Virtual Volumes (Dynamic Tiering)
192
Script Examples
194
Configuring Iscsi Virtual Ports
197
Setting an Iscsi Virtual Port
198
External Volume Operations
199
Creating External Volumes (Iscsi)
201
Script Examples
204
Virtual Partition Manager Operations
207
Displaying CLPR Information
208
Checking Result of CLPR Transfer
209
Configuring Server Priority Manager by Specifying Ports and Wwns of Hbas
210
Using and Managing Server Priority Manager
211
Setting SPM Names for Wwns and Registering Them to the SPM Group
212
Cautions about Using Server Priority Manager
217
Virtual Storage Machine Operations
222
Adding Ldevs to a Virtual Storage Machine
223
Removing the Virtual Storage Machine
224
Data Replication Operations with CCI
225
About Data Replication Operations
226
Using CCI with Shadowimage and Truecopy
227
Using CCI with Thin Image
228
Using CCI with Global-Active Device
229
Shadowimage Duplicated Mirroring
230
Shadowimage Cascading Pairs
231
Restrictions for Shadowimage Cascading Volumes
232
Restriction for Truecopy/Shadowimage Cascading Volumes
233
Truecopy Takeover Commands
234
Takeover-Switch Function
236
Swap-Takeover Function
237
SVOL-Takeover Function
238
PVOL-Takeover Function
239
Truecopy Local Commands
241
Truecopy/Shadowimage/Universal Replicator Pair Status
242
Sidefile Cache for Truecopy Async
251
Truecopy Async/Universal Replicator Error State
253
Settings
254
Setting the Fence Level
256
Copy-On-Write Snapshot Operations
257
Pair Operations and Commands for Copy-On-Write Snapshot and Thin Image
258
Copy-On-Write Snapshot Pair Status
259
Pair Status Relationship to Copy-On-Write Snapshot Commands
260
Controlling Volume Migration
261
Commands to Control Volume Migration
263
Relations between "CC" Command Issues and Status
266
Restrictions for Volume Migration
267
Command Specifications
270
Pairsplit Command
271
Notice on System Operation
274
Configuration Examples
276
Duplication of CCI Applications
278
Requirements for Duplication of CCI
281
Note for Duplication of CCI
282
Discovering a Remote Volume
283
Data Protection Operations with CCI
287
Data Protection Operations
288
Restrictions on Data Retention Utility Volumes
289
Restrictions on Database Validator
290
Protection Parameters and Operations
291
Data Protection Facility Specifications
293
Examples for Configuration and Protected Volumes
294
Operation Authority with CMD Security Enabled
295
Permission Command
296
Raidscan -Find Verify [MU#]
297
Pairdisplay -F[D]
298
Systems
299
Environment Variables
300
Horcmperm
301
Examples of Using CCI Commands
303
Group Version Control for Mixed Storage System Configurations
304
Volume Discovery Function
305
Mountvol Attached to Windows 2012/2008/2003/2000 Systems
307
System Buffer Flushing Function
308
Special Facilities for Windows Systems
311
GPT Disk for Windows
312
Directory Mount Facility for Windows Systems
314
Host Group Control
316
Commands and Options Including a Host Group
317
Using CCI SLPR Security
318
Specifying the SLPR Protection Facility
319
SLPR Configuration Examples
320
Troubleshooting
325
General Troubleshooting
326
Operational Notes and Restrictions for CCI Operations
327
Error Messages and Error Codes
330
Command Error Messages
332
Generic Error Codes (Horctakeover and Pair Commands)
342
Generic Error Codes (Raidscan, Raidqry, Raidar, Horcctl)
344
Specific Error Codes
345
SSB Codes
346
SSB Codes Returned by the Configuration Setting Command (Raidcom)
348
Other SSB Codes Indicating Internal Errors
521
Calling Hitachi Data Systems Customer Support
523
Advertisement
Hitachi USP VM Configuration Manual (70 pages)
for SGI IRIX Host Attachment
Brand:
Hitachi
| Category:
Storage
| Size: 0.63 MB
Table of Contents
Table of Contents
5
Preface
7
Intended Audience
8
Product Version
8
Document Revision Level
8
Changes in this Revision
8
Document Organization
9
Referenced Documents
9
Document Conventions
10
Convention for Storage Capacity Values
11
Getting Help
12
Comments
12
Introduction
13
About the Hitachi Universal Storage Platform V
14
Device Types
16
Installation and Configuration Roadmap
23
Installing the USP V
25
Installation and Configuration Checklist
26
Preparing for the USP V Installation
28
Hardware Installation Considerations
28
LUN Manager Software Installation
29
Setting the Host Mode
30
Setting the Host Mode Options
31
Configuring the USP V Fibre-Channel Ports
32
Port Address Considerations for Fabric Environments
34
Loop ID Conflicts
34
Configuring the Host Fibre-Channel HBA(S)
35
Connecting the USP V System to the SGI IRIX Host
36
Verifying New Device Recognition
37
Device Files and Wwns
40
Configuring the New Disk Devices
43
Partitioning the Disk Devices
44
Enabling Command Tag Queuing
48
Creating the File Systems
50
EFS™ File System
50
XFS ® File System
51
Creating the Mount Directories and Mounting the Devices
52
Verifying the File Systems
52
Setting the Auto-Mount Parameters
53
Configuring the New Disk Devices
55
Host/Application Failover
56
SNMP Remote System Management
57
Troubleshooting
59
Troubleshooting Error Conditions
60
Calling the Hitachi Data Systems Support Center
61
SCSI TID Maps for Fibre-Channel Adapters
63
Online Device Installation
65
Acronyms and Abbreviations
67
Advertisement
Related Products
Hitachi UM-S700
Hitachi USP V
Hitachi Ultrastar US103036FL3800
Hitachi Sabrent USB-DSC8
Hitachi UST-547
Hitachi UST-9120
Hitachi UST-5710-7.5
Hitachi UST-678
Hitachi UST-5413
Hitachi UST-5299
Hitachi Categories
Projector
Air Conditioner
Drill
Power Tool
TV
More Hitachi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL