Sign In
Upload
Manuals
Brands
Honeywell Manuals
Control Panel
MRP-2002E
Honeywell MRP-2002E Manuals
Manuals and User Guides for Honeywell MRP-2002E. We have
2
Honeywell MRP-2002E manuals available for free PDF download: Instruction Manual, Manual
Honeywell MRP-2002E Instruction Manual (160 pages)
Agent Release Control System six-zone releasing fire control panel
Brand:
Honeywell
| Category:
Control Panel
| Size: 2.67 MB
Table of Contents
Installation Precautions
3
Table of Contents
5
Section 1: Product Description
13
Product Features
13
Specifications
14
Controls and Indicators
17
Components
18
Optional Modules and Accessories
18
Section 2: Installation
20
Backbox Mounting
20
Operating Power
23
Input Circuits
24
Output Circuits
27
1: Outputs/Notification Appliance/Releasing Circuits
27
Stat-X Aerosol Generators
28
2: Special Application DC Power Output Connections
29
3: Relays - Programmable
29
Power-Limited Wiring Requirements
30
Installation of Optional Modules
31
1: CAC-5X Class a Converter Module
31
Installation
31
Wiring Nacs and Idcs for Class a
32
2: 4XTMF Municipal Box Transmitter Option Module
33
4XTMF Transmitter Module Installation
33
3: ANN-SEC Option Card
34
ANN-BUS Devices
35
Guidelines
35
1: ANN-BUS Wiring
36
Calculating Wiring Distance for ANN-BUS Modules
36
Powering ANN-BUS Devices from Auxiliary Power Supply
38
2: ANN-BUS Device Addressing
39
3: ANN-80 Remote LCD Annunciator
39
Specifications
39
Installation
39
Wiring ANN-80 to FACP
40
Programming
41
4: ANN-S/PG Serial/Parallel Printer Interface Installation
41
Specifications
42
Printer Installation
42
PRN-6F Printer Installation
43
5: ANN-I/O LED Driver Module
45
ANN-I/O Board Layout
45
Specifications
45
ANN-I/O Connection to FACP
46
ANN-I/O Module LED Wiring
46
6: ANN-LED Annunciator Module
47
Specifications
47
Mounting/Installation
47
ANN-LED Board Layout and Connection to FACP
48
7: ANN-RLY Relay Module
48
Specifications
48
Mounting/Installation
49
ANN-RLY Board Layout and Connection to FACP
49
Section 3: Programming
50
User Programming
50
Initial Power-Up
51
Programming Screens Description
51
Programming and Passwords
52
Master Programming Level
53
1: FACP CONFIG (Application Templates)
53
2: Input Zones
54
3: Output Circuits
58
Enabled
58
Type
59
Silence
60
Auto Silence
60
Silence Inhibited
61
Coding
61
Synchronized Nac Operation
62
4: Cross Input Zones
63
5: On-Board Relays
63
6: System Setup
64
Abort Type
65
Timers
65
Banner
67
Time-Date
68
Trouble Reminder
69
Charger Disable
69
Canadian Option
69
Secondary ANN-BUS Option
70
7: Ann-Bus
70
ANN-BUS Enabled
70
ANN-BUS Modules
70
Auto-Configure
71
ANN-S/PG Options
71
ANN-I/O LED Zone Assignments
72
Options
72
ANN-RLY Options
73
8: History
74
View Events
75
Erase History
75
9: Walktest
75
10: Clear Program
76
11: Password Change
76
Maintenance Programming Level
77
1: Input Zones - Enable/Disable
77
2=History
77
3: Walktest
78
4: Time-Date
78
Section 4: Operating Instructions
80
Panel Control Buttons
80
1: Acknowledge/Step
80
2: Alarm Silenced (Domestic/Export Versions)/Signal Silence (Canadian Version)
80
3: Drill/Hold 2 Sec (Domestic/Export Versions)/Alarm Signal (Canadian Version)
80
4: Reset
80
Indicators
81
Normal Operation
81
Trouble Operation
82
Alarm Operation
83
Supervisory Operation
84
Disable/Enable Operation
84
Waterflow Circuits Operation
85
Detector Functions
85
Time Functions: Real-Time Clock
85
Coded NAC Operation
85
Release Stage/Nac Operation
85
Special System Timers
86
1: Silence Inhibit Timer
86
2: Autosilence Timer
86
3: Trouble Reminder
86
4: Pre-Discharge Delay Timers
86
5: Discharge Timers
86
6: Waterflow Delay Timer
86
Walktest
87
Read Status
87
1: FACP Configuration
88
2=Input Zones
88
3=Output Circuits
88
4: Cross Input Zones
89
5: On-Board Relays
89
6: System Settings
89
7: Timers
89
8: Daylight Savings
90
9: History
90
10: Print
90
11: Ann-Bus
90
Section 5: Power Supply Calculations
91
Overview
91
Calculating the AC Branch Circuit
91
Calculating the System Current Draw
92
1: Overview
92
2: How to Use Table 5.3 on Page 93 to Calculate System Current Draw
92
Calculating the Battery Size
94
1: NFPA Battery Requirements
94
2: Selecting and Locating Batteries
94
Appendix A: Circuit Mapping and Cross-Zoning
95
A.1: Input-To-Output Circuit Mapping and Cross-Zone Operation
95
A.1.1: Mapping Input Zones to Output Circuits for Direct Activation
96
A.1.2: Mapping Input Zones to Release Circuits for Cross Zone Activation
97
A.1.3: Complex Examples of Cross Zoning and I/O Mapping for Release Circuits
99
Appendix B: FACP Configuration Templates
100
B.1: Template 1: Cross-Zone System - with Horn
101
B.2: Template 2: Single Zone System with Horn
104
B.3: Template 3: Single Hazard - Cross-Zone
107
B.4: Template 4: Single Hazard - Count One
110
B.5: Template 5: Single Hazard - Single Detector, Cross-Zone NAC
113
B.6: Template 6: Single Hazard - Cross-Zone NAC
116
B.7: Template 7: Cross-Zone System - Bell/Horn/Strobe
119
B.8: Template 8: Single Hazard, Single Detector - Bell/Horn/Strobe
122
B.9: Template 9: Dual Hazard - Cross-Zone
125
B.10: Template 10: Dual Hazard - Single Detector
128
B.11: Template 11: Agent/Waterflow - Cross-Zone
131
B.12: Template 12: Agent/Waterflow - Single Detector
134
B.13: Template 13: HP CO2 Single Detector
137
Appendix C: NFPA Standard-Specific Requirements
140
C.1: NFPA 72 Auxiliary Fire Alarm System
143
C.2: Central Station/Remote Station Transmitter: Connection to FACP Dry Contacts
146
Appendix D: FACP with Keltron
147
Appendix E: Testing & Maintenance
148
E.1: Testing
148
E.1.1: Inspection
148
E.1.2: Alarm Test
148
E.1.3: Detector Testing
148
Test I 3 Series Detectors as Follows
149
E.2: Maintenance
149
Appendix F: Wire Requirements
150
F.1: NAC Wiring
151
Index
152
MRP-2002, MRP-2002E, MRP-2002C Agent Release Control System
157
Operating Instructions
157
Advertisement
Honeywell MRP-2002E Manual (136 pages)
Agent Release Control System
Brand:
Honeywell
| Category:
Control Systems
| Size: 1.94 MB
Table of Contents
Table of Contents
4
Product Description
11
Product Features
11
Specifications
13
Controls and Indicators
14
Components
15
Optional Modules and Accessories
16
Installation
17
Backbox Mounting
17
Operating Power
20
Input Circuits
21
Output Circuits
23
Outputs/Notification Appliance/Releasing Circuits
23
Special Application DC Power Output Connections
24
Relays - Programmable
24
Power-Limited Wiring Requirements
25
Installation of Optional Modules
26
CAC-5X Class a Converter Module
26
Installation
26
Wiring Nacs and Idcs for Class a
27
4XTMF Municipal Box Transmitter Option Module
28
4XTMF Transmitter Module Installation
29
ANN-BUS Devices
30
ANN-BUS Wiring
30
Calculating Wiring Distance for ANN-BUS Modules
30
Wiring Configuration
32
Powering ANN-BUS Devices from Auxiliary Power Supply
33
ANN-BUS Device Addressing
33
Remote LCD Annunciator
34
Specifications
34
Installation
34
Mounting
34
Opening/Closing Annunciator
34
Wiring ANN-80 to FACP
35
ANN-S/PG Serial/Parallel Printer Interface Installation
37
Specifications
37
PRN-6F Printer Installation
37
Connecting PRN-6F Printer
38
Setting Printer Options
38
ANN-I/O LED Driver Module
39
ANN-I/O Board Layout
39
Specifications
39
ANN-I/O Connection to FACP
40
ANN-I/O Module LED Wiring
41
ANN-LED Annunciator Module
42
ANN-LED Board Layout
42
Specifications
42
Mounting/Installation
42
ANN-LED Connection to FACP
43
ANN-RLY Relay Module
44
ANN-RLY Board Layout
44
Specifications
44
Mounting/Installation
44
ANN-RLY Connection to FACP
45
Programming
46
User Programming
46
Initial Power-Up
47
Programming Screens Description
47
Programming and Passwords
48
Master Programming Level
49
FACP CONFIG (Application Templates)
50
Input Zones
50
Output Circuits
57
Enabled
58
Type
58
Release Circuit 1 or Release Circuit 2
58
Release Stage NAC
59
Silence
59
Auto Silence
60
Silence Inhibited
60
Coding
61
Synchronized NAC Operation
62
Cross Input Zones
63
On-Board Relays
64
System Setup
64
Abort Type
65
Timers
66
Pre-Discharge
66
Discharge Timer
67
Waterflow Delay
68
AC Loss Delay
68
Banner
68
Time-Date
70
Time
70
Date
70
Clock Format
71
Daylight Savings Time
71
Trouble Reminder
71
Charger Disable
72
Ann-Bus
72
ANN-BUS Enabled
72
ANN-BUS Modules
73
Auto-Configure
73
Ann-S/Pg Options
74
ANN-I/O LED Zone Assignments
75
Options
76
ANN-RLY Options
77
History
78
View Events
78
Erase History
78
Walktest
79
Clear Program
80
Password Change
80
Maintenance Programming Level
81
Input Zones - Enable/Disable
82
History
82
Walktest
83
Time-Date
84
Operating Instructions
85
Panel Control Buttons
85
Acknowledge/Step
85
Alarm Silenced
85
Drill/Hold 2 Sec
85
Reset
85
Indicators
86
Normal Operation
86
Trouble Operation
87
Alarm Operation
88
Supervisory Operation
89
Disable/Enable Operation
90
Waterflow Circuits Operation
90
Detector Functions
90
Time Functions: Real-Time Clock
90
Coded NAC Operation
90
Release Stages
91
Special System Timers
91
Silence Inhibit Timer
91
Autosilence Timer
91
Trouble Reminder
91
Pre-Discharge Delay Timer
91
Discharge Timer
91
Waterflow Delay Timer
91
Walktest
92
Read Status
92
FACP Configuration
93
Input Zones
93
Output Circuits
94
Cross Input Zones
95
On-Board Relays
95
System Settings
96
Timers
96
Daylight Savings
97
History
97
Print
97
Ann-Bus
98
Power Supply Calculations
99
Overview
99
Calculating the AC Branch Circuit
99
Calculating the System Current Draw
100
Overview
100
How to Use Table 5-3 on Page 101 to Calculate System Current Draw
100
Calculating the Battery Size
102
NFPA Battery Requirements
102
Selecting and Locating Batteries
102
Circuit Mapping and Cross-Zoning
103
Input-To-Output Circuit Mapping and Cross-Zone Operation
103
Mapping Input Zones to Output Circuits for Direct Activation
104
Mapping Input Zones to Release Circuits for Cross Zone Activation
105
Complex Examples of Cross Zoning and I/O Mapping for Release Circuits
107
FACP Configuration Templates
108
Template 1: Cross-Zone System - with Horn
109
Template 2: Single Zone System with Horn
112
NFPA Standard-Specific Requirements
115
NFPA 72 Auxiliary Fire Alarm System
118
Central Station/Remote Station Transmitter: Connection to FACP Dry Contacts
121
FACP with Keltron
122
Testing & Maintenance
123
Testing
123
Inspection
123
Alarm Test
123
Detector Testing
123
Maintenance
124
Wire Requirements
125
NAC Wiring
126
Advertisement
Related Products
Honeywell MRP-2002
Honeywell MRP-2002C
Honeywell Fire-Lite Alarms MRP-2001
Honeywell Fire-Lite Alarms MRP-2001E
Honeywell Fire-Lite Alarms MRP-2001C
Honeywell MB-Secure 5000
Honeywell Fire-Lite Alarms MS-9600UDLSE
Honeywell Fire-Lite Alarms MS-9050UDE
Honeywell Fire-Lite Alarms MS-5UD-7E
Honeywell Fire-Lite Alarms MS-10UD-3E
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL