Sign In
Upload
Manuals
Brands
HP Manuals
Measuring Instruments
1660CS
HP 1660CS Manuals
Manuals and User Guides for HP 1660CS. We have
4
HP 1660CS manuals available for free PDF download: User Manual, Service Manual, Training Manual
HP 1660CS User Manual (347 pages)
Logic Analyzers
Brand:
HP
| Category:
Measuring Instruments
| Size: 2.33 MB
Table of Contents
Table of Contents
6
1 Logic Analyzer Overview to Make a Measurement
19
2 Connecting Peripherals to Connect a Mouse
26
To Connect a Keyboard
27
To Connect to an HP-IB Printer
28
To Connect to an RS-232-C Printer
30
To Connect to a Parallel Printer
31
To Connect to a Controller
32
3 Using the Logic Analyzer
34
Accessing the Menus
36
To Access the System Menus
37
To Access the Analyzer Menus
39
To Access the Scope Menus
41
Using the Analyzer Menus
43
To Label Channel Groups
43
To Create a Symbol
45
To Examine an Analyzer Waveform
47
To Examine an Analyzer Listing
49
To Compare Two Listings
51
The Inverse Assembler
53
To Use an Inverse Assembler
53
4 Using the Trigger Menu
56
Specifying a Basic Trigger
58
To Assign Terms to an Analyzer
59
To Define a Term
60
To Change the Trigger Specification
61
Changing the Trigger Sequence
62
To Add Sequence Levels
63
To Change Macros
64
Setting up Time Correlation between Analyzers
65
To Set up Time Correlation between Two State Analyzers
66
To Set up Time Correlation between a Timing and a State Analyzer
66
Arming and Additional Instruments
67
To Arm Another Instrument
67
To Arm the Oscilloscope with the Analyzer
68
To Receive an Arm Signal from Another Instrument
70
Managing Memory
71
To Selectively Store Branch Conditions (State Only)
72
To Place the Trigger in Memory
73
To Set the Sampling Rates (Timing Only)
74
5 Triggering Examples
76
Single-Machine Trigger Examples
78
To Store and Time the Execution of a Subroutine
79
To Trigger on the Nth Iteration of a Loop
81
To Trigger on the Nth Recursive Call of a Recursive Function
83
To Trigger on Entry to a Function
85
To Capture a Write of Known Bad Data to a Particular Variable
86
To Trigger on a Loop that Occasionally Runs too Long
87
To Verify Correct Return from a Function Call
88
To Trigger after All Status Bus Lines Finish Transitioning
89
To Find the Nth Assertion of a Chip Select Line
90
To Verify that the Chip Select Line Is Strobed after the Address Is Stable
91
To Trigger When Expected Data Does Not Appear When Requested
92
To Test Minimum and Maximum Pulse Limits
93
To Detect a Handshake Violation
95
To Detect Bus Contention
96
Cross-Arming Trigger Examples
97
To Examine Software Execution When a Timing Violation Occurs
98
To Look at Control and Status Signals During Execution of a Routine
99
To Detect a Glitch
100
To Capture the Waveform of a Glitch
101
To View Your Target System Processing an Interrupt
102
To Trigger Timing Analysis of a Count-Down on a Set of Data Lines
103
To Monitor Two Coprocessors in a Target System
104
Special Displays
105
To Interleave Trace Lists
106
To View Trace Lists and Waveforms on the same Display
107
6 File Management
110
Transferring Files Using the Flexible Disk Drive
112
To Save a Configuration
113
To Load a Configuration
115
To Save a Listing in ASCII Format
116
To Save a Screen's Image
117
To Load Additional Software
118
7 Reference
120
Configuration Capabilities
122
Probing
124
General-Purpose Probing System Description
127
Oscilloscope Probes
130
Assembling the Probing System
131
Keyboard Shortcuts
135
Moving the Cursor
135
Entering Data into a Menu
136
Using the Keyboard Overlays
136
Common Menu Fields
137
Print Field
138
Run/Stop Field
139
Roll Fields
140
Disk Drive Operations
141
Disk Operations
141
Autoload
143
Format
143
Pack
143
Load and Store
144
The RS-232-C, HP-IB, and Centronics Interfaces
145
The HP-IB Interface
146
The RS-232-C Interface
146
The Centronics Interface
147
System Utilities
148
Real Time Clock Adjustments Field
148
Update FLASH ROM Field
148
Shade Adjustments
149
The Analyzer Configuration Menu
150
Type Field
150
Illegal Configuration
150
The Analyzer Format Menu
151
Pod Threshold Field
151
State. Acquisition Modes (State Only)
151
Timing Acquisition Modes (Timing Only)
152
Clock Inputs Display
153
Pod Clock Field (State Only)
153
Master and Slave Clock Fields (State Only)
156
Symbols Field
159
Label Fields
160
Label Polarity Fields
161
The Analyzer Trigger Menu
162
Trigger Sequence Levels
162
Modify Trigger Field
162
Timing Trigger Macro Library
163
State Trigger Macro Library
165
Modifying the User Macro
167
Resource Terms
170
Arming Control Field
173
Acquisition Control Field
175
Count Field (State Only)
176
The Analyzer Listing Menu
177
Markers
177
The Analyzer Waveform Menu
179
Sec/DIV Field
179
Accumulate Field
179
Delay Field
179
Waveform Label Field
180
Waveform Display
181
The Analyzer Mixed Display Menu
182
Interleaving State Listings
182
Time-Correlated Displays
183
Markers
183
The Analyzer Chart Menu
184
Min and Max Scaling Fields
185
Markers/Range Field
185
The Analyzer Compare Menu
186
Reference Listing Field
187
Difference Listing Field
187
Copy Listing to Reference Field
188
Find Error Field
188
Compare Full/Compare Partial Field
188
Mask Field
189
Bit Editing Field
189
Oscilloscope Common Menus
190
Run/Stop Options
190
Autoscale
191
Time Base
192
The Scope Channel Menu
193
Offset Field
193
Probe Field
194
Coupling Field
194
Preset Field
194
The Scope Display Menu
195
Mode Field
195
Connect Dots Field
196
Grid Field
196
Display Options Field
197
The Scope Trigger Menu
198
Trigger Marker
198
Mode/Arm Menu
198
Level Field
200
Source Field
201
Slope Field
202
Count Field
202
Auto-Trig Field
203
When Field
204
Count Field
206
The Scope Marker Menu
207
Manual Time Markers Options
207
Automatic Time Markers Options
209
Manual/Automatic Time Markers Option
213
Voltage Markers Options
213
Channel Label Field
215
The Scope Auto Measure Menu
216
Input Field
216
Automatic Measurements Display
216
Automatic Measurement Algorithms
218
8 System Performance Analysis (SPA) Software
222
System Performance Analysis Software
223
What Is System Performance Analysis
225
Getting Started
227
SPA Measurement Processes
229
Using State Overview, State Histogram, and Time Interval
242
Using SPA with Other Features
251
9 Concepts
252
The File System
254
Directories
255
File Types
256
Transitional Mode Theory
258
125-Mhz Transitional Mode
258
250-Mhz Transitional Mode
259
Other Transitional Timing Considerations
262
The Trigger Sequence
263
Trigger Sequence Specification
264
Analyzer Resources
266
Timing Analyzer
269
State Analyzer
269
Configuration Translation between HP Logic Analyzers
270
The Analyzer Hardware
272
HP 1660CS-Series Analyzer Theory
273
Logic Acquisition Board Theory
276
Oscilloscope Board Theory
279
Self-Tests Description
283
10 Troubleshooting
284
Analyzer Problems
286
Unwanted Triggers
286
No Activity on Activity Indicators
287
Capacitive Loading
287
No Trace List Display
287
Preprocessor Problems
288
Target System will Not Boot up
288
Slow Clock
289
Erratic Trace Measurements
290
Inverse Assembler Problems
291
No Inverse Assembly or Incorrect Inverse Assembly
291
Inverse Assembler will Not Load or Run
292
Error Messages
293
Inverse Assembler Not Found
293
No Configuration File Loaded
293
Selected File Is Incompatible
293
Slow or Missing Clock
294
Waiting for Trigger
294
Must Have at Least 1 Edge Specified
295
Time Correlation of Data Is Not Possible
295
Maximum of 32 Channels Per Label
295
Timer Is off in Sequence Level N Where It Is Used
296
Timer Is Specified in Sequence, but Never Started
296
Inverse Assembler Not Loaded - Bad Object Code
296
Measurement Initialization Error
297
Warning: Run HALTED Due to Variable Change
297
11 Specifications
298
Accessories
299
Specifications (Logic Analyzer)
300
Specifications (Oscilloscope)
301
Characteristics (Logic Analyzer)
302
Characteristics (Oscilloscope)
302
Supplemental Characteristics (Logic Analyzer)
303
Supplemental Characteristics (Oscilloscope)
306
Operating Environment
310
12 Operator's Service
312
Preparing for Use
314
To Inspect the Logic Analyzer
315
To Apply Power
315
To Set the Line Voltage
316
To Degauss the Display
317
To Clean the Logic Analyzer
317
To Test the Logic Analyzer
317
Calibrating the Oscilloscope
318
Set up the Equipment
318
Load the Default Calibration Factors
319
Self Cal Menu Calibrations
320
Troubleshooting
322
To Use the Flowcharts
323
To Check the Power-Up Tests
325
To Run the Self-Tests
326
To Test the Auxiliary Power
333
Advertisement
HP 1660CS Service Manual (238 pages)
Logic Analyzers
Brand:
HP
| Category:
Measuring Instruments
| Size: 3.11 MB
Table of Contents
Table of Contents
5
General Information
11
Accessories
12
Specifications (Logic Analyzer)
13
Specifications (Oscilloscope)
14
Specifications (Pattern Generator)
14
Characteristics (Logic Analyzer)
15
Characteristics (Oscilloscope)
15
Characteristics (Pattern Generator)
16
Supplemental Characteristics (Logic Analyzer)
17
Supplemental Characteristics (Oscilloscope)
20
Recommended Test Equipment (Logic Analyzer)
24
Recommended Test Equipment (Oscilloscope)
25
Recommended Test Equipment (Pattern Generator)
26
Preparing for Use
27
To Inspect the Logic Analyzer
28
To Apply Power
29
To Operate the User Interface
29
To Set the Line Voltage
29
To Degauss the Display
30
To Clean the Logic Analyzer
30
To Test the Logic Analyzer
30
Testing Performance
31
To Perform the Self-Tests
33
To Make the Test Connectors (Logic Analyzer)
37
To Test the Threshold Accuracy (Logic Analyzer)
39
Set up the Equipment
39
Set up the Logic Analyzer
40
Connect the Logic Analyzer
40
Test the TTL Threshold
41
Test the ECL Threshold
43
Test the − User Threshold
44
Test the 0 V User Threshold
46
Test the Next Pod
47
To Test the Glitch Capture (Logic Analyzer)
48
Set up the Equipment
48
Set up the Logic Analyzer
49
Connect the Logic Analyzer
49
Test the Glitch Capture on the Connected Channels
51
Test the Next Channels
53
To Test the Single-Clock, Single-Edge, State Acquisition (Logic Analyzer)
54
Set up the Equipment
54
Set up the Logic Analyzer
55
Connect the Logic Analyzer
57
Verify the Test Signal
59
Check the Setup/Hold Combination
61
Test the Next Channels
66
To Test the Multiple-Clock, Multiple-Edge, State Acquisition (Logic Analyzer)
67
Set up the Equipment
67
Set up the Logic Analyzer
68
Connect the Logic Analyzer
70
Verify the Test Signal
72
Check the Setup/Hold with Single Clock Edges, Multiple Clocks
74
Test the Next Channels
78
To Test the Single-Clock, Multiple-Edge, State Acquisition (Logic Analyzer)
79
Set up the Equipment
79
Set up the Logic Analyzer
80
Connect the Logic Analyzer
82
Verify the Test Signal
84
Check the Setup/Hold with Single Clock, Multiple Clock Edges
86
Test the Next Channels
89
To Test the Time Interval Accuracy (Logic Analyzer)
91
Set up the Logic Analyzer
91
Connect the Logic Analyzer
94
Acquire the Data
94
To Test the CAL OUTPUT Ports (Oscilloscope)
95
Set up the Equipment
95
Set up the Logic Analyzer
96
Verify the DC CAL OUTPUT Port
97
Set up the Logic Analyzer
98
Verify the AC CAL OUTPUT Port
98
To Test the Input Resistance (Oscilloscope)
99
Set up the Equipment
99
Set up the Logic Analyzer
100
Connect the Logic Analyzer
101
Acquire the Data
102
Perform an Operational Accuracy Calibration
102
To Test the Voltage Measurement Accuracy (Oscilloscope)
103
Set up the Equipment
103
Set up the Logic Analyzer
104
Connect the Logic Analyzer
105
Acquire the Data
106
To Test the Offset Accuracy (Oscilloscope)
107
Set up the Equipment
107
Set up the Logic Analyzer
108
Connect the Logic Analyzer
109
Acquire the Zero Input Data
110
Acquire the DC Input Data
111
To Test the Bandwidth (Oscilloscope)
112
Set up the Equipment
112
Set up the Logic Analyzer
113
Connect the Logic Analyzer
115
Acquire the Data
116
To Test the Time Measurement Accuracy (Oscilloscope)
117
Set up the Equipment
117
Set up the Logic Analyzer
118
Connect the Logic Analyzer
120
Acquire the Data
120
To Test the Trigger Sensitivity (Oscilloscope)
121
Set up the Equipment
121
Set up the Logic Analyzer
122
Connect the Logic Analyzer
124
Acquire the Data
124
Performance Test Record (Logic Analyzer)
125
Performance Test Record (Oscilloscope)
131
Performance Test Record (Pattern Generator)
134
Calibrating and Adjusting
136
Logic Analyzer Calibration
136
To Calibrate the Oscilloscope
137
Set up the Equipment
137
Load the Default Calibration Factors
138
Self Cal Menu Calibrations
139
To Adjust the CRT Monitor Alignment
140
To Adjust the CRT Intensity
142
Troubleshooting
145
To Use the Flowcharts
146
To Check the Power-Up Tests
161
To Run the Self-Tests
162
To Test the Power Supply Voltages
168
To Test the CRT Monitor Signals
170
To Test the Keyboard Signals
171
To Test the Flexible Disk Drive Voltages
172
To Test the Hard Disk Drive Voltages
174
To Perform the BNC Test
175
To Test the Logic Analyzer Probe Cables
176
To Verify Pattern Output (HP 1660CP-Series Only)
180
To Test the Auxiliary Power
182
Replacing Assemblies
183
To Remove and Replace the Handle
187
To Remove and Replace the Feet and Tilt Stand
187
To Remove and Replace the Cover
187
To Remove and Replace the Disk Drive Assembly
188
To Remove and Replace the Power Supply
189
To Remove and Replace the CPU Board
189
Switch Actuator Assembly
189
To Remove and Replace SIMM Memory
190
To Remove and Replace the Switch Actuator Assembly
191
To Remove and Replace the Rear Panel Assembly
192
To Remove and Replace the HP 1660C-Series Acquisition Board
193
To Remove and Replace the HP 1660CS-Series Oscilloscope Board
194
To Remove and Replace the HP 1660CP-Series Pattern Generator Board
195
To Remove and Replace the Front Panel and Keyboard
196
To Remove and Replace the Intensity Adjustment
196
To Remove and Replace the Monitor
197
To Remove and Replace the Handle Plate
197
Intensity Adjustment
197
To Remove and Replace the Fan
198
To Remove and Replace the Line Filter
198
To Remove and Replace the HP 1660CP-Series Pattern Generator Cables
199
To Remove and Replace the HP-IB and RS-232-C Cables
199
To Remove and Replace the I/O Board
200
To Return Assemblies
200
Replaceable Parts
201
Replaceable Parts Ordering
202
Replaceable Parts List
203
Exploded View
204
Power Cables and Plug Configurations
208
Theory of Operation
209
Block-Level Theory
211
The HP 1660C/CS/CP Series Logic Analyzer
211
The Logic Acquisition Board
215
The Oscilloscope Board
218
The Pattern Generator Board
221
Self-Tests Description
223
Power-Up Self-Tests
223
System Tests (System PV)
224
Analyzer Tests (Analy PV)
228
Oscilloscope Tests (Scope PV)
230
Pattern Generator Tests (Patt Gen)
231
Hp-Ib
235
HP 1660CS Training Manual (140 pages)
Training Kit for Logic Analyzers
Brand:
HP
| Category:
Measuring Instruments
| Size: 5.77 MB
Table of Contents
Table of Contents
7
Using the Analyzer and Understanding the Measurement Process
11
Using the Analyzer
13
Understanding the Measurement Process
14
Introduction to Timing Analysis
19
Before You Begin
21
Put the Analyzer into Timing Mode
22
Change a Label Name
23
Modify Channel Assignments
24
Define a Term for the Timing Trigger
25
Set up the Trigger Specification
26
Trigger on the Term and Examine the Waveform
27
Introduction to State Analysis
29
Before You Begin
31
Put the Analyzer into State Mode
32
Set up the State Clock
33
Change a Label Name
34
Modify Channel Assignments
35
Define a Term for the State Trigger
36
Set up Level 1 of the State Trigger Specification
37
Set up Level 2 of the State Trigger Specification
38
Run the State Analyzer and View and Change the State Listing
39
Create Symbols to Display State Data
40
Create Additional Symbols
41
Select and View Symbols in the State Listing
42
Comparing State Traces before You Begin
45
Check the Configuration
46
Set up the State Trigger Specification
47
Run the Analyzer and View the State Listing
48
Copy the State Listing to the Compare Reference Listing
49
Change the Jumper to Acquire a Different State Listing
50
Run the Analyzer and Find the Errors
51
Mixed Mode - Correlation of State and Timing Data
53
Before You Begin
55
Connect the Timing Analyzer
56
Put the Analyzer into State and Timing Modes
57
Change a Label Name and Modify Channel Assignments
58
Turn on the TCOUNT Label in the Waveform Menu
58
Clear the Timing Analyzer Trigger
59
Set up the State Trigger Specification
59
Enable Time Correlation between the Timing and State Analyzers
60
Arm the Timing Analyzer with the State Analyzer
61
View the Mixed-Mode Display with Time-Correlated Markers
62
Advanced State Triggering
63
Before You Begin
65
Put the Analyzer into State Mode
66
Define State Trigger Terms "A" through "D
67
Define State Trigger Term "E" and Range1
68
Add State Trigger Sequence Levels
69
Set up Level 1 of the State Trigger Specification
70
Set up Level 2 of the State Trigger Specification
71
Set up Level 3 of the State Trigger Specification
72
Set up Level 4 of the State Trigger Specification and Define a Combination Trigger Term
73
Check the Trigger Specification
75
Run the State Analyzer and View the Data
76
Using the Oscilloscope
79
Before You Begin
81
Connect the Channel 1 Oscilloscope Probe
82
Get the Waveform on the Display
83
Delete Channel 2 from the Display
84
Zoom and Scroll through the Clock Waveform
85
Measure the Clock Period Manually
86
Measure the Clock Period with Auto Measure
87
Read Voltage with the Markers
88
Triggering the Oscilloscope with the Timing Analyzer
89
Before You Begin
91
Set the Jumpers
92
Connect the Oscilloscope Probe
93
Get the Waveform on the Display
94
Change the Oscilloscope Trigger
95
Turn on the Timing Analyzer
96
Set up the Timing Format Menu
97
Define the Timing Trigger Term "Edge 1
98
Set up the Timing Trigger Specification
99
Arm the Oscilloscope with the Timing Analyzer
100
Add Oscilloscope Waveform to the Timing Waveforms
101
Capture the Glitch with the Timing Analyzer and Oscilloscope
102
Align the Glitch Displayed by the Oscilloscope and Analyzer
103
Using the Pattern Generator
105
Before You Begin
107
Connect the Pattern Generator
108
Turn on the Timing Analyzer
109
Change a Label Name
110
Modify Channel Assignments
111
Set up the Timing Analyzer Trigger Term
112
Add a Pattern Generator Label to the Timing Waveform Display
113
Set up the Pattern Generator Format Menu
114
Program the Pattern Generator Output
116
Add Program Lines
117
Start the Pattern Generator and View the Walking Ones Pattern
118
Stop the Pattern Generator
119
Introduction to Inverse Assembly
121
Load the Inverse Assembler and Sample Listing
123
View the Address, Data, and Status Labels
124
View the Assembly Listing
125
Filter the Captured Data
126
Setting the Jumpers and Loading the Configurations
127
To Set the Jumpers
129
To Load a Configuration File
131
All about the Logic Analyzer Training Board
133
Power Source
134
Circuit Description
134
Jumpers
135
Schematic
136
Advertisement
HP 1660CS User Manual (108 pages)
Logic Analyzers
Brand:
HP
| Category:
Measuring Instruments
| Size: 3.93 MB
Table of Contents
Table of Contents
6
Connecting and Configuring
8
To Connect to Your Network
10
To Configure the Network Addresses
11
To Verify Connectivity with the Ping Utility
14
To Mount the Logic Analyzer
15
Accessing the Logic Analyzer File System
18
To Mount the File System Via NFS
20
To Access the File System Via Ftp
25
Using the X Window Interface to Start the Interface
29
To Close the Interface
33
To Load the Custom Fonts
35
Additional Information
37
Retrieving and Restoring Data to Copy ASCII Measurement Data
40
To Copy Raw Measurement Data
42
To Restore Raw Measurement Data
43
To Strip LIF Structure from Raw Measurement Data
44
To Copy Screen Images from \Systern\Graphics
46
To Copy Status Information from \Status
48
To Copy Configurations from Setup.raw
49
To Restore Configurations
50
Programming the Logic Analyzer
52
To Set up for Ethernet LAN Programming
55
To Write Programs that Open \Systern\Prograrn
61
Concepts
66
Directory Structure of the Logic Analyzer's File System
68
Dynamic Files
71
LAN-Related Fields in the Logic Analyzer's Menus
72
Troubleshooting
74
Troubleshooting the Initial Connection
76
Assess the Problem
76
Troubleshooting in a Workstation Environment
78
Troubleshooting in an MS-DOS Environment
81
Troubleshooting in an MS Windows Environment
84
Verify the Logic Analyzer Performance
87
Status Number
89
Network Status Information
92
Solutions to Common Problems
94
If You Cannot Connect to the Logic Analyzer
94
If You Cannot Mount the Logic Analyzer File System
95
If You Cannot Access the File System Via Ftp
95
If You Cannot Start the X Window Interface
96
If Your X Window Looks Odd
96
If You Cannot Copy Files from the Logic Analyzer
96
If You Cannot Restore Raw Files
97
If You Cannot Telnet to the Command Parser Socket
97
If You Get an "Operation Timed-Out" Message
98
If the Logic Analyzer Begins to Operate Slowly
98
If the Logic Analyzer Does Not Respond
98
If All else Fails
98
Getting Service Support
99
HP On-Site Service
99
Return to HP Service
99
Advertisement
Related Products
HP 1660CS-Series
HP HP 1660CP Series
HP 1660E Series
HP 1660ES Series
HP 1660EP Series
HP 1660 Series
HP 1660A Series
HP 1660AS Series
HP 1660C Series
HP HP 1661CP
HP Categories
Desktop
Laptop
Server
Monitor
Switch
More HP Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL