Sign In
Upload
Manuals
Brands
Sanyo Manuals
Air Conditioner
W-3WAY ECO-i XMHX1252
Sanyo W-3WAY ECO-i XMHX1252 Manuals
Manuals and User Guides for Sanyo W-3WAY ECO-i XMHX1252. We have
9
Sanyo W-3WAY ECO-i XMHX1252 manuals available for free PDF download: Technical Data Manual, Service Manual, Installation Instructions Manual
Sanyo W-3WAY ECO-i XMHX1252 Technical Data Manual (265 pages)
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 18.12 MB
Table of Contents
Section 1
4
Table of Contents
4
Section 1: OUTLINE of W-3WAY ECO-I SYSTEM
8
Features of W-3WAY ECO-I SYSTEM
8
Section 2
11
Model Selecting and Capacity Calculator
12
System Design
28
Electrical Wiring
34
Installation Instructions
41
Section 3
55
Control of W-3WAY ECO-I SYSTEM
57
Main Operating Functions
57
Room Temperature Control
57
Automatic Control for Heating and Cooling
58
How to Use the Wireless Remote Controller
59
Optional Controller (Remote Controller)
59
Wireless Remote Controller
59
Receiver
62
RCS-SH80AAB.WL for 4-Way Air Discharge Semi-Concealed (X Type)
63
RCS-XM18AAB.WL for 4Way Air Discharge Semi-Concealed (XM Type)
66
Ceiling-Mounted (T Type)
69
Concealed Duct High-Static Pressure (D Type)
72
RCS-SH1AAB for Wall-Mounted (K Type)
78
How to Use the Timer Remote Controller
79
Timer Remote Controller
79
Timer Remote Controller/Rcs-TM80BG
79
Names and Operations
80
Setting the Present Time
85
Weekly Program Function
86
Outing Function
91
Sleeping Function
93
System Controller
95
System Controller / SHA-KC64UG
95
How to Use the System Controller
96
Functions of Buttons
97
Display
99
How to Start Group Operation
100
How to Start Collective Operation
101
How to Install the System Controller
102
Electrical Wiring
103
Address Switch Setting
104
Mode Setting
106
How to Perform Zone Registration
107
ZONE Registration Table
108
How to Check Overlapping of Central Address no
112
Operation Buttons
113
Simplifi Ed Remote Controller
113
Simplifi Ed Remote Controller / RCS-KR1AGB
113
Display
115
Operation
116
Tips for Energy Saving
117
Troubleshooting
117
How to Install the Simplifi Ed Remote Controller
118
Parts Supplied with Simplifi Ed Remote Controller
118
Simplifi Ed Remote Controller Installation Guidelines
118
How to Wire the Simplifi Ed Remote Controller
119
Guidelines for Using 2 Simplifi Ed Remote Controllers
120
Remote Controller Test Run Setting
120
Parts Supplied with Remote Sensor
121
Remote Sensor
121
Remote Sensor / ART-K45AGB
121
Remote Sensor Installation Guidelines
121
How to Install the Remote Sensor
122
How to Wire the Remote Sensor
123
Important Information When Using Together with Remote Controller Switch
123
Section 4
125
Outdoor Unit
126
Specifi Cations
126
Dimensional Data
131
Multiple Unit Installation Example
132
Refrigerant Flow Diagram
134
Noise Criterion Curves
135
Specifi Cations
136
Way Air Discharge Semi-Concealed Type (X, XM Type)
136
Major Component Specifi Cations
142
Dimensional Data
148
Noise Criterion Curves
151
Air Flow Distance/Temperature Chart
152
Specifi Cations
157
Way Air Discharge Semi-Concealed Type (a Type)
157
Way Air Discharge Semi-Concealed Type(a Type)
157
Major Component Specifi Cations
160
Dimensional Data
163
Noise Criterion Curves
164
Air Flow Distance/Temperature Chart
165
Concealed Duct Type (U Type)
166
Concealed Duct Type(U Type)
166
Specifi Cations
166
Major Component Specifi Cations
171
Dimensional Data
176
Noise Criterion Curves
180
Increasing the Fan Speed
182
Concealed Duct High-Static Pressure Type (D Type)
183
Concealed Duct High-Static Pressure Type(D Type)
183
Specifi Cations
183
Major Component Specifi Cations
185
Dimensional Data
187
Noise Criterion Curves
188
Indoor Fan Performance
189
Ceiling-Mounted Type (T Type)
190
Ceiling-Mounted Type(T Type)
190
Specifi Cations
190
Major Component Specifi Cations
193
Dimensional Data
196
Noise Criterion Curves
197
Air Flow Distance/Temperature Chart
198
Specifi Cations
200
Wall-Mounted Type (K Type)
200
Wall-Mounted Type(K Type)
200
Major Component Specifi Cations
205
Dimensional Data
210
Noise Criterion Curves
211
Air Flow Distance/Temperature Chart
212
Section 5
214
Preparing for Test Run
215
Test Run Procedure
216
Main Outdoor Unit PCB Setting
217
Auto Address Setting
219
Caution for Pump down
225
Remote Controller Test Run Settings
225
Meaning of Alarm Messages
226
Outdoor Unit/Indoor Unit
229
Electric Wiring Diagram CHDZ09053
230
Electrical Data
230
Outdoor Unit
230
Electric Wiring Diagram CHDZ14053
232
Electric Wiring Diagram XHX1252/1852/2452/3652
234
Indoor Unit
234
Electric Wiring Diagram XMHX1252/1852
236
Electric Wiring Diagram AHX0752/0952/1252
237
Electric Wiring Diagram UHX0752/1252/1852/2452/3652
239
Electric Wiring Diagram DHX3652
241
Electric Wiring Diagram DHX4852
243
Electric Wiring Diagram THX1252/1852/2452
245
Electric Wiring Diagram KHX0752/0952/1252/1852
247
Electric Wiring Diagram KHX2452
249
Outdoor Unit Control PCB
252
Outdoor Unit Control PCB CR-CHDZ14053
252
Pcb and Functions
252
Outdoor Unit Filter PCB FIL-CHDX14053
253
Outdoor Unit HIC Board HIC-CHDX14053
253
Functions (for CR-CHDZ14053)
254
Indoor Unit Control PCB Switches and Functions
257
For AC Fan Motor (CR-UXRP71B-B)
258
CR1 (for CR-KR74GXH56A/KHX0752~KHX1852) (Wall-Mounted)
260
CR1 (for CR-KR254GXH56A/KHX2452) (Wall-Mounted)
261
CR2 (for POW-KR74GXH56/KHX0752~KHX2452) (Wall-Mounted)
262
Explanation of Functions (CR-KR74GXH56A, CR-KR254GXH56A, POW-KR74GXH56)
263
Advertisement
Sanyo W-3WAY ECO-i XMHX1252 Installation Instructions Manual (106 pages)
W-3WAY ECO-i System Air Conditioner
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 7.74 MB
Table of Contents
Important
2
Special Precautions
2
Check of Density Limit
3
Precautions for Installation Using New Refrigerant
4
New Refrigerant R410A Cannot be Used for Earlier Models
5
Table of Contents
6
1 General
8
Tools Required for Installation (Not Supplied)
8
Accessories Supplied
8
Type of Copper Tube and Insulation Material
8
Additional Materials Required for Installation
8
Tubing Length
11
Tubing Size
13
Straight Equivalent Length of Joints
13
Additional Refrigerant Charge
13
System Limitations
14
Installation Standards
14
Check of Limit Density
15
Installing Distribution Joint
15
Optional Solenoid Valve Kit
18
Example of Tubing Size Selection and Refrigerant Charge Amount
21
2 Selecting the Installation Site
23
Indoor Unit
23
Outdoor Unit
24
Precautions When Installing in Heavy Snow Areas
25
Dimensions of Wind Ducting
26
Unit Installation
26
Dimensions of Snow Ducting
27
3 How to Install the Indoor Unit
28
4 Way Air Discharge Semi-Concealed Type (X Type)
28
Preparation for Suspending
28
Suspending the Indoor Unit
28
Placing the Unit Inside the Ceiling
28
Installing the Drain Piping
29
Checking the Drainage
30
How to Install the Ceiling Panel
31
Special Remarks
34
Preparation for Suspending
35
Placing the Unit Inside the Ceiling
35
Installing the Drain Piping
36
Checking the Drainage
37
How to Install the Ceiling Panel
37
1-Way Air Discharge Semi-Concealed Type (a Type)
40
Suspending the Indoor Unit
41
Placing the Unit Inside the Ceiling
41
Installing the Drain Piping
42
Checking the Drainage
43
Electrical Power Wiring
44
How to Install the Ceiling Panel
44
Concealed Duct Type (U Type)
48
Required Minimum Space for Installation and Service
48
Suspending the Indoor Unit
49
Installing the Drain Piping
50
Checking the Drainage
50
Increasing the Fan Speed
51
Concealed Duct High-Static Pressure Type (D Type)
52
Required Minimum Space for Installation and Service
52
Suspending the Indoor Unit
53
Installing the Drain Piping
54
Caution for Ducting Work
54
Ceiling-Mounted Type (T Type)
55
Required Minimum Space for Installation and
55
Suspending the Indoor Unit
56
Duct for Fresh Air
58
Shaping the Tubing
58
Installing the Drain Piping
58
Wall-Mounted Type (K Type)
60
Removing the Rear Panel from the Unit
60
Selecting and Making a Hole
60
Installing the Rear Panel Onto the Wall
60
Removing the Grille to Install the Indoor Unit
61
Preparing the Tubing
61
Shaping the Tubing
62
Installing the Drain Hose
62
When Using Wireless Remote Controller Instead of Wired Remote Controller
63
How to Install the Outdoor Unit
64
Installing the Outdoor Unit
64
Remove the Brackets Used for Transport
65
Routing the Tubing
65
Prepare the Tubing
66
Connect the Tubing
66
5 Electrical Wiring
68
General Precautions on Wiring
68
Recommended Wire Length and Wire Diameter for Power Supply System
68
Wiring System Diagram
69
Important Note When Wiring for Common Type
73
Important Note When Wiring for XM Type
75
6 How to Process Tubing
76
Connecting Tubing between Indoor and Outdoor Units
77
Insulating the Refrigerant Tubing
78
Taping the Tubes
79
Finishing the Installation
79
7 Air Purging
80
Air Purging with a Vacuum Pump (for Test Run) Preparation
80
8 Test Run
83
Preparing for Test Run
83
Test Run Procedure
84
Main Outdoor Unit PCB Setting
86
Auto Address Setting
87
Remote Controller Test Run Settings
93
Caution for Pump down
93
Meaning of Alarm Messages
94
9 Appendix
97
4-Way Air Discharge Semi-Concealed Type (X, XM Types)
97
1-Way Air Discharge Semi-Concealed Type
99
Concealed Duct (High-Static Pressure) Type (U, D Types)
101
Troubleshooting
102
Tips for Energy Saving
102
Ceiling-Mounted Type (T Type)
103
Wall-Mounted Type (K Type)
105
Sanyo W-3WAY ECO-i XMHX1252 Service Manual (142 pages)
2-WAY ECO-i MULTI SYSTEM
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 2.65 MB
Table of Contents
Table of Contents
4
Control Functions
6
Section 1: CONTROL FUNCTIONS
6
Introduction
7
Selecting Outdoor Unit for Operation
8
2 Selecting Outdoor Unit for Operation
9
Compressor Control
9
Special Controls
14
Other Controls
19
Operation of Solenoid Valves
20
Outdoor Unit Electronic Thermostatic Expansion Valves [MOV1, MOV2 & MOV4]
22
Outdoor Fan Control
24
Demand Control
25
Indoor Unit Control of the Electronic Control Valve
26
Rap Valve Kit Control
28
Indoor Unit Refrigerant Oil Self Recovery Control
29
Discharge Temperature
30
Current Protection
31
Pressure Sensor Failure
32
Backup Operation
33
Service Maintenance Functions
35
Other Functions
37
Outdoor Unit Repair Procedures
40
Removing Panels
41
Removing Electrical Component Box and Duct
42
Discharging Compressor Oil
44
Backup Operation
45
Backup Operation
47
Recovering Refrigerant
48
Checking for Leakage after Repair
53
Evacuating System
54
Charging Compressor Oil
55
Pumping out Refrigerant from Outdoor Unit
59
Pumping out Refrigerant from Outdoor Unit
61
Compressor
62
High and Low Pressure Sensors
74
Replacing 4-Way Valve
75
Outdoor Unit Maintenance Remote Controller
78
Overview
79
Functions
80
Ordinary Display Controls and Functions
81
Monitoring Operations
86
Outdoor Unit Alarm History Monitor
88
Mode Settings
89
Remote Controller Functions
92
Simple Settings Function
93
Simple Settings Function
94
Detailed Settings Function
95
Remote Controller Servicing Functions
106
Section 5: TROUBLE DIAGNOSIS
110
Contents of Remote Controller Switch Alarm Display
111
Trouble Diagnosis
111
Outdoor Unit Control Panel LED Display
113
Remote Controller Servicing Functions
114
W-2WAY ECO-I Alarm Codes
116
Blinking Inspection Display on the Remote Controller
136
Inspection of Parts
137
Test Pin
138
Thermister Characteristics Curve
139
Thermister Characteristic Curve
140
Advertisement
Sanyo W-3WAY ECO-i XMHX1252 Service Manual (128 pages)
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 28.32 MB
Table of Contents
Section 1
4
Table of Contents
4
Test Run
5
Test Run
6
Preparing for Test Run
6
Test Run Procedure
7
Setting of Unit Control PCB
8
Main Outdoor Unit PCB Setting
8
Auto Address Setting
10
Remote Controller Test Run Settings
16
Caution for Pump down
17
Meaning of Alarm Messages
18
Section 2
21
Main Operating Functions
22
Remote Control Functions
22
Room Temperature Control
22
Automatic Control for Heating and Cooling
23
How to Use the Wireless Remote Controller
24
Wireless Remote Controller
24
Receiver
27
Operation
28
Using the Wireless Remote Control Unit
29
Address Settings
30
Emergency Operation
32
Trouble Diagnosis
34
How to Use the Timer Remote Controller
35
Timer Remote Controller
35
Names and Operations
36
How to Install the Remote Controller
38
Installation Manual for Timer Remote Controller
38
Group Control Using 2 Remote Controllers
39
Indoor Unit Setting Mode
39
Remote Controller Setting Mode
39
To Display the Sensor Temperature
39
To Display the Trouble History
39
Setting the Present Time
41
Weekly Program Function
42
Outing Function
47
Sleeping Function
49
Wired Remote Controller Test Run Settings
50
Simple Settings Function
51
Detailed Settings Function
53
Remote Controller Servicing Functions
60
Contents of Remote Controller Switch Alarm Display
64
Outdoor Unit Control PCB LED Display
66
W-3WAY ECO-I Alarm Codes
67
Blinking (Inspection) Display on the Remote Controller
88
Outdoor Unit Control Pcb/Indoor Unit Control Pcb
91
Outdoor Unit Control PCB
92
Outdoor Unit Control PCB CR-CHDZ09663
92
Pcb and Functions
92
Outdoor Unit Filter PCB FIL-CHDX14053
93
Outdoor Unit HIC Board HIC-CHDX14053
93
Functions (for CR-CHDZ09663)
94
Indoor Unit Control PCB
97
AC Fan Motor (for CR-UHX0762)
98
DC Fan Motor (for CR-UMHX0762)
98
XM Type (for CR-XMHX1252, POW-XM075XH)
99
CR1 (for CR-KR74GXH56A/KHX0752~KHX1252) (Wall-Mounted)
100
CR1 (for CR-KR254GXH56A/KHX1862~KHX2452) (Wall-Mounted)
101
CR2 (for POW-KH2672R/KHX0752~KHX2452) (Wall-Mounted)
102
Explanation of Functions
103
Explanation of Functions (CR-KXRP56AN, CR-KXRP80AN, POW-KRP50A)
106
Instructions for Connecting External Heater to ECO-I Indoor Units
108
Self-Diagnosis Function Table
113
Functions
118
Outdoor Unit Maintenance Remote Controller
118
Overview
118
Service Checker
118
Ordinary Display Controls and Functions
119
Monitoring Operations
123
Outdoor Unit Alarm History Monitor
124
Setting the Outdoor Unit EEPROM Data
125
Sanyo W-3WAY ECO-i XMHX1252 Service Manual (146 pages)
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 6.51 MB
Sanyo W-3WAY ECO-i XMHX1252 Service Manual (93 pages)
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 6.42 MB
Table of Contents
Table of Contents
4
Control Functions
5
Introduction
6
Compressor Control
7
Special Controls
11
Other Control
14
Operation of Solenoid Valves
14
Outdoor Unit Electronic Control Valve (Motor Valve) Control [MOV1]
14
Outdoor Fan Control
15
Indoor Unit Electronic Control Valve Control
16
Indoor Special Control
17
Discharge Gas Temperature
18
Current Protection
18
Pressure Sensor Failure
19
Way Valve Failure [L18]
19
Servicing and Maintenance Functions
20
Outdoor Unit Repair Procedures
21
Layout Diagram: Sensors and Solenoid Valves
22
Layout Diagram: Sensors
23
Removing Panels
24
Discharging Oil in Compressor
25
Recovering Refrigerant
26
Checking for Leakage after Repair
31
Evacuating System
32
Charging Compressor Oil
33
Pumping out Refrigerant from Outdoor Unit
37
Compressor
39
High Pressure Sensor
42
Outdoor Unit Maintenance Remote Controller
43
Overview
44
Functions
45
Ordinary Display Controls and Functions
46
Monitoring Operations
51
Outdoor Unit Alarm History Monitor
53
Mode Settings
54
Remote Controller Functions
57
Simple Settings Function
58
Detailed Settings Function
60
Remote Controller Servicing Functions
71
Trouble Diagnosis
75
Contents of Remote Controller Switch Alarm Display
76
Outdoor Unit Control Panel LED Display
78
Remote Controller Servicing Functions
79
Mini ECO-I Alarm Codes
80
Inspection of Parts (Outdoor Unit)
92
Sanyo W-3WAY ECO-i XMHX1252 Installation Instructions Manual (48 pages)
ECO-i System Air Conditioner
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 2.47 MB
Table of Contents
Special Precautions
2
Check of Density Limit
3
Table of Contents
4
1 General
5
Tools Required for Installation (Not Supplied)
5
Accessories Supplied
5
Type of Copper Tube and Insulation Material
5
Additional Materials Required for Installation
5
2 Selecting the Installation Site
8
Indoor Unit
8
3 How to Install the Indoor Unit
9
Concealed Duct Type (U Type)
9
Required Minimum Space for Installation and Service
9
Suspending the Indoor Unit
10
Installing the Drain Piping
11
Checking the Drainage
11
Increasing the Fan Speed
12
When Installing the Indoor Unit
13
Required Minimum Space for Installation and Service
13
Slim Concealed-Duct Type (um Type)
14
Required Minimum Space for Installation and Service
14
Preparations before Installation
15
For Bottom Intake
15
Installing the Duct
16
Suspending the Indoor Unit
17
Installing the Drain Piping
18
Checking the Drainage
18
Increasing the Fan Speed
19
Wall-Mounted Type (K Type)
20
Removing the Rear Panel from the Unit
20
Selecting and Making a Hole
20
Installing the Rear Panel Onto the Wall
20
Removing the Grille to Install the Indoor Unit
21
Preparing the Tubing
21
Shaping the Tubing
22
Installing the Drain Hose
22
When Using Wireless Remote Controller Instead of Wired Remote Controller
23
External Electronic Expansion Valve Kit (ATK-SVRK56BA)
24
Flare Insulator
24
Floor-Standing Type (F Type) Concealed Floor-Standing Type (FM Type)
28
Required Minimum Space for Installation and Service
28
Dimensions and Part Names
28
Removing and Attaching the Front Panel
30
Installing the Refrigerant Tubing
30
Installing the Drain Piping
31
Installing the Remote Controller
31
Insulating Tape (White)
31
Insulating Tape (Black)
31
Vinyl Clamp
31
Insulating Tape (Black and Long)
31
Supplement on Drain Piping
32
4 Electrical Wiring
33
General Precautions on Wiring
33
Recommended Wire Length and Wire Diameter for Power Supply System
33
Wiring System Diagram
34
Important Note When Wiring for Common Type
37
5 How to Process Tubing
39
Connecting Tubing between Indoor and Outdoor Units
40
Insulating the Refrigerant Tubing
41
Drain Insulator
41
Taping the Tubes
42
Finishing the Installation
42
6 Appendix
43
Name of Parts
43
Care and Cleaning
44
Troubleshooting
47
Tips for Energy Saving
47
Sanyo W-3WAY ECO-i XMHX1252 Installation Instructions Manual (54 pages)
W-3WAY ECO-i System Air Conditioner
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 3.52 MB
Table of Contents
Important
2
Please Read before Starting
2
Check of Density Limit
3
Precautions for Installation Using New Refrigerant
4
New Refrigerant R410A Cannot be Used for Earlier Models
5
Table of Contents
6
Check of Density Limit
6
New Refrigerant R410A Cannot be Used for Earlier Models
6
Precautions for Installation Using New Refrigerant
6
1 General
7
Tools Required for Installation (Not Supplied)
7
Accessories Supplied
7
Type of Copper Tube and Insulation Material
7
Additional Materials Required for Installation
7
Tubing Length
8
Tubing Size
9
Straight Equivalent Length of Joints
10
Additional Refrigerant Charge
10
System Limitations
11
Installation Standards
11
Check of Limit Density
12
Installing Distribution Joint
12
Optional Distribution Joint Kits
13
Optional Solenoid Valve Kit
15
Example of Tubing Size Selection and Refrigerant Charge Amount
18
Refrigerant Charge Amount
19
2 Selecting the Installation Site
20
Outdoor Unit
20
Precautions When Installing in Heavy Snow Areas
21
Dimensions of Wind Ducting
22
Dimensions of Snow Ducting
23
3 How to Install the Outdoor Unit
24
Transporting
24
Installing the Outdoor Unit
24
Remove the Brackets Used for Transport
25
Routing the Tubing
25
Prepare the Tubing
26
Connect the Tubing
26
4 Electrical Wiring
28
General Precautions on Wiring
28
Recommended Wire Length and Wire Diameter for Power Supply System
28
Wiring System Diagram
29
5 How to Process Tubing
32
Connecting the Refrigerant Tubing
32
Connecting Tubing between Indoor and Outdoor Units
33
Insulating the Refrigerant Tubing
34
Taping the Tubes
35
Finishing the Installation
35
6 Air Purging
36
Air Purging with a Vacuum Pump (for Test Run) Preparation
36
Test Run.
38
Length
38
7 Test Run
39
Preparing for Test Run
39
Test Run Procedure
40
Main Outdoor Unit PCB Setting
42
Auto Address Setting
43
Remote Controller Test Run Settings
49
Caution for Pump down
49
Meaning of Alarm Messages
50
Sanyo W-3WAY ECO-i XMHX1252 Installation Instructions Manual (50 pages)
W-2WAY System Air Conditioner
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 3.26 MB
Table of Contents
Important
2
Please Read before Starting
2
Check of Density Limit
3
Precautions for Installation Using New Refrigerant
4
New Refrigerant R410A Cannot be Used for Earlier Models
5
Table of Contents
6
General
7
Tools Required for Installation (Not Supplied)
7
Accessories Supplied
7
Type of Copper Tube and Insulation Material
7
Additional Materials Required for Installation
7
Tubing Length
8
Tubing Size
9
Straight Equivalent Length of Joints
10
Additional Refrigerant Charge
10
System Limitations
10
Check of Limit Density
11
Installing Distribution Joint
11
Optional Distribution Joint Kits
12
Example of Tubing Size Selection and Refrigerant Charge Amount
14
Selecting the Installation Site
16
Outdoor Unit
16
Shield for Horizontal Exhaust Discharge
17
Installing the Outdoor Unit in Heavy Snow Areas
17
Precautions When Installing in Heavy Snow Areas
17
Dimensions of Wind Ducting
18
Dimensions of Snow Ducting
19
How to Install the Outdoor Unit
20
Transporting
20
Installing the Outdoor Unit
20
Routing the Tubing
21
Prepare the Tubing
22
Connect the Tubing
22
Electrical Wiring
24
General Precautions on Wiring
24
Recommended Wire Length and Wire Diameter for Power Supply System
24
Wiring System Diagram
25
How to Process Tubing
28
Connecting the Refrigerant Tubing
28
Connecting Tubing between Indoor and Outdoor Units
29
Insulating the Refrigerant Tubing
30
Taping the Tubes
31
Finishing the Installation
31
Air Purging
32
Air Purging with a Vacuum Pump (for Test Run) Preparation
32
Test Run
35
Preparing for Test Run
35
Test Run Procedure
36
Main Outdoor Unit PCB Setting
37
Auto Address Setting
39
Remote Controller Test Run Settings
45
Caution for Pump down
46
Meaning of Alarm Messages
47
Advertisement
Related Products
Sanyo W-3WAY ECO-i XMHX1852
Sanyo XMS1272
Sanyo XMS0972
Sanyo XMHS1272
Sanyo XMHS0972
Sanyo XM18AAB
Sanyo XS1872
Sanyo XS3632
Sanyo XS3632 / C3632
Sanyo X
Sanyo Categories
Projector
TV
Air Conditioner
Security Camera
LCD TV
More Sanyo Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL