Sign In
Upload
Manuals
Brands
Siemens Manuals
Network Hardware
SIMATIC ET 200M
User Manuals: Siemens SIMATIC ET 200M Controller
Manuals and User Guides for Siemens SIMATIC ET 200M Controller. We have
4
Siemens SIMATIC ET 200M Controller manuals available for free PDF download: Operating Instructions Manual, Manual, Workshop Manual
Siemens SIMATIC ET 200M Operating Instructions Manual (271 pages)
Distributed I/O device
Brand:
Siemens
| Category:
Industrial Equipment
| Size: 10.16 MB
Table of Contents
Preface
3
Table of Contents
7
Product Overview
11
What Are Distributed I/O Devices
11
What Is PROFIBUS DP
11
What Is PROFINET IO
13
200M Distributed I/O Device
14
IM 153-X: Variants and Properties
17
Brief Instructions on Commissioning
22
Commissioning on PROFIBUS DP
22
Introduction
22
Mounting the ET 200M
24
Wiring the ET 200M
25
Putting Hardware into Service
27
Configuring the ET 200M in the SIMATIC Manager
27
Creating a User Program
30
Switching on ET 200M
30
Evaluating Diagnostic Messages
31
Commissioning on PROFINET IO
33
Assignment Planning
34
Structure Variants for PROFIBUS DP
34
Detecting the Configuration Variant by Means of the IM 153-2
36
Configuration Possibilities for PROFIBUS DP
36
Distributed I/O with IM 153-1
36
Passing on Parameter Assignment Data from the PD / PC with IM 153-2
37
Configurable FM in a Configuration with IM 153-2
39
FOC Network with IM 153-2 FO
40
Structure Variants and Configuration Possibilities for PROFINET IO
41
Configuring the Mechanical Structure
41
Horizontal or Vertical Configuration
41
Clearance Measurements
42
Arrangement of the Modules of an ET 200M Standard Installation
44
Arrangement of the Modules for the Function "Change During Operation" and / or "Redundancy
45
Configuring the Electrical Structure
48
General Rules and Regulations for Operating the ET 200M
48
Operating the ET 200M with Process I/O on a Grounded Supply
50
Configuration of an ET 200M with Ungrounded Reference Potential
54
Configuration of the ET 200M with Isolated Modules
55
Configuration of the ET 200M with Non-Isolated Modules
57
Installation
58
Overview
58
Mounting Sequence
58
Installing the DIN Rail
59
Installing Modules on the Mounting Rail (Standard Installation)
63
Installing Active Bus Modules and Modules (Configuration with Active Bus Modules)
65
After Installation
67
Setting the PROFIBUS Address
68
Connecting
70
Overview
70
Connecting PROFIBUS DP
70
Connecting the Bus Connector
70
Connecting the Fiber-Optic Cable to the IM 153-2 FO
71
Connecting PROFINET IO
74
Connecting IM 153-4 PN
74
Wiring the Power Supply and Modules
78
Wiring Rules
78
Wiring the Power Supply and IM 153-X
79
Wiring Front Connectors of the Signal Modules
81
Connecting Shielded Cables Via a Shield Connecting Element
84
Commissioning
87
Profibus Dp
87
Commissioning the DP Slave
87
IM 153-1 Start-Up
89
IM 153-2 / 153-2 FO Start-Up
90
PROFIBUS DPV1 Operation
93
Profinet Io
95
Configuring in STEP 7
95
Configuring by Means of GSD File
96
Assigning Device Names to the I/O Device
96
Configuring Ports of the IM 153-4 PN
98
Commissioning ET 200M for PROFINET IO
99
Startup of ET 200M on PROFINET IO
100
Maintenance and Service
101
Wiring of the ET 200M
101
Replacing the Power Supply Module
101
Replacing the IM 153-1
102
Replacing the IM 153-2 or IM 153-2 FO
103
Replacing IM 153-4 PN
106
Replace Modules Without the Function "Change During Operation
108
Replace Modules with the Function "Change During Operation
111
Replacing the Bus Module
114
Exchanging Fuses in Digital Output Modules
115
Updating the IM 153-X
116
When Should You Update the IM 153-X
116
Update of the IM 153-1 / -2Ax0X
116
Update of the IM 153-2Bx00
116
How to Update the IM 153-2Bxx1
120
Saving Data and Updating the IM 153-4 PN
123
Functions
128
Support for I/O Modules with Expanded Input Data
128
Time Stamping the Input Signals with IM 153-2
129
Principles
129
Functionalities
131
Time Stamp with 10 Ms Precision
131
Highly Precise Time Stamp with 1 Ms Precision
133
Time Synchronization for Time Stamping
134
Time Stamping in the Redundant System
137
Time Stamping Within the S7-400
139
With STEP 7 in Customer Applications
139
With the PCS 7 System Solution
139
Time Stamping Outside of S7-400
141
Prerequisites
141
Operating Principle
144
Brief Introduction to Commissioning the Time Stamping
146
Time Synchronization
147
Configuring the Time Stamping
148
Structure of the Process Interrupt
151
Structure of the IM 153-2 Messages
153
Significance of Special Messages
155
Diagnosis for Time Stamping
156
Clock Synchronization on the I/O Bus
158
Redundancy with IM 153-2
160
System Modification During Operation
163
System Modification in a Non-Redundant System
163
System Modification in a Redundant System
163
Isochrone Mode
166
What Is Isochronous
166
Configuring the Isochrone Mode
169
Identification and Maintenance Data (I&M Data)
173
I&M Data for PROFIBUS DP
173
I&M Data for PROFINET IO
177
Direct Data Exchange
179
Snmp
180
Interrupt, Error and System Messages
181
Profibus Dp
181
Diagnostics with LED Display
181
Diagnosis with STEP 7 or STEP 5
184
Structure of the Diagnosis
187
Structure of Slave Diagnosis
187
Station Statuses 1 to 3
190
Master PROFIBUS Address
191
Manufacturer ID
192
Evaluating the Slave Diagnosis
192
Identifier-Related Diagnosis
193
Module Status
194
Channel-Specific Diagnostics
195
H Status (Only with S7-400 H and Normal Redundancy)
199
Interrupts
201
Evaluating Interrups from Station Diagnosis
211
Profinet Io
213
Diagnostics Using LED Display on IM 153-4 PN Interface Module
213
Diagnostic Messages of the Electronic Modules
215
Evaluating the Interrupts of the ET 200M
216
Maintenance Interrupts
217
Channel Diagnostics
218
Error Types for Modules
218
Diagnostics of Incorrect Configuration States of ET 200M on PROFINET IO
218
Diagnostics Events Triggered by a STOP of the I/O Controller
218
Technical Specifications
219
Standards and Approvals
220
Parameters of the IM 153-X
228
Technical Specifications of the IM 153-X
230
Technical Specifications of the IM 153-4 PN Interface Module
233
Response Time of the ET 200M
238
Using the ET 200M in the Potentially Explosive Area Zone 2
240
Compatibilities between the IM 153-X
241
Compatibilities between the Versions of IM 153 and IM 153-1
241
Compatibilities between the Versions of IM 153-2 / -2 FO
243
RC Network with 1 MΩ for Configuration with Ungrounded Reference Potential
246
Order Numbers for the ET 200M
247
Glossary
252
Index
266
Advertisement
Siemens
SIMATIC ET 200M
Manual
Siemens SIMATIC ET 200M Manual (242 pages)
Distributed I/O Device
Brand:
Siemens
| Category:
I/O Systems
| Size: 1.58 MB
Table of Contents
Table of Contents
10
1 Product Overview
16
What Are Distributed I/O Devices
16
Typical PROFIBUS-DP Network Structure
18
What Is the ET 200M Distributed I/O Device
19
Structure of the ET 200M Distributed I/O Device (Example)
19
Components of an ET 200M
21
IM 153-X: Variants and Features
23
IM 153-X: Features and Variants
24
Front View of the IM 153-1 and IM 153-2AA02/-2AB01
25
Front View of the IM 153-2Bx00
26
2 Getting Started
28
Introduction
29
200M Components Needed for the Sample Configuration
29
Order Numbers for the Sample Configuration
30
Prerequisites
31
Installation
31
Wiring
32
Wiring of the ET 200M
33
Putting Hardware into Service
34
Configuration
35
Configuration Table for ET 200M
35
DP Slave Properties Dialog Box for SM
36
Integration into the User Program
37
Switching on
37
Distributed I/O Device ET 200M EWA-4NEB780600602-06
37
Diagnostics
38
3 Configuration Options with the ET 200M
40
Distributed I/Os with the IM 153-1
40
Distributed I/Os with the IM
41
Forwarding Parameterization Data from the PG/PC with the IM
42
The IM 153-2
42
Forwarding Parameterization Data with an IM 153-2 and HART Modules
42
Parameterizable FM in a Configuration with an IM 153-2
43
Parameterizable FM in an ET 200M with an IM
43
Time Stamping with 10 Ms Accuracy
45
Sample Configuration for Time Stamping of Signal Changes
45
Sample Configuraton with 2 IM 153-2 for Redundancy in a
46
Time Stamping with 3 Ms Accuracy
47
Time Synchronization with Flexible Time Interval
47
Redundancy with the IM 153-2
48
Redundancy with 2 IM 153-2 Modules in an H System
49
Configuration Modification in RUN
50
Configuration Modification in RUN in Redundant System
50
Configuration Modification in RUN in Non-Redundant System
53
Clock Synchronism
54
Clock-Synchronized Interrupts" Dialog Box
56
Option" Dialog Box
57
DP Slave Properties" Dialog Box
58
Identification Data
61
Structure of Data Record 248 for ET 200M
61
Structure of Data Records with Identification Data
62
Fiber-Optic Network with the IM 153-2 FO
64
Direct Communication
65
4 Installation
66
Setting the PROFIBUS Address
66
Mechanical Configuration
67
Horizontal and Vertical Installation
67
Clearance Measurements
67
Arrangement of the Modules in an ET 200M Configuration
67
Horizontal and Vertical Installation of an ET 200M
67
Clearance Measurements for an ET 200M Installation on a
68
Mounting Rack
68
Arrangement of the Modules of an ET 200M
69
Rules for Configuring the "Module Change During Operation" and "Redundancy" Functions
70
Installation Setup with Active Bus Modules
72
Installation
73
Fixing Holes of the 2 M Rail
74
Fixing Holes for Rails
75
Connecting the Protective Conductor to the Rail
76
Standard Configuration (Installing Modules on the Rail)
77
Module Accessories
77
Installing the Modules on the Rail
78
Configuration with Active Bus Modules (Installing Active Bus Modules and Modules)
79
After Installation
80
Slot Numbers for S7 Modules
80
Applying Slot Numbers to the Modules
81
Connecting the Bus Connector
82
Connecting the Fiber-Optic Cable to the IM 153-2 FO
83
Inserting the Fiber-Optic Cables into the IM 153-2 FO
84
Setting the PROFIBUS Address
85
5 Wiring
88
Electrical Configuration
89
General Rules and Regulations on Operating an ET 200M
89
Operating the ET 200M with Process I/O Modules on a Grounded Supply
92
DIN VDE Specifications for Configuring a PLC System
92
S7-300 Modules Operated on a Grounded Incoming Supply
94
S7-300 Modules Operated from the PS
95
Configuring the ET 200M with Ungrounded Reference Potential
96
Configuring the ET 200M with Galvanically Isolated Modules
97
Simplified Illustration of the Configuration with Isolated Modules
98
Configuring the ET 200M with Non-Isolated Modules
99
Potentials in a Configuration with the Non-Isolated Analog
99
Wiring
100
Wiring Rules
100
Wiring Rules for the Power Supply and the IM 153-X
100
Wiring Rules for Module Front Connectors
101
Wiring the Power Supply and IM 153-X
102
Wiring the PS 307 Power Supply Module and the IM 153-X with
103
Wiring the Front Connectors of the Signal Modules
104
Bringing the Front Connector into the Wiring Position
105
Wiring the Front Connector
106
Preparing the Signal Module for Operation
107
Connecting Shielded Cables Via a Shield Contact Element
108
Assignment of Cable Cross-Sections and Terminal Elements
108
Attaching Shielded 2-Wire Cables to a Shield Contact Element
109
6 Commissioning and Diagnostics
110
Startup of the IM 153-1
110
Startup of the IM 153-2
110
Prerequisites for Commissioning
111
Software Prerequisites for Commissioning
111
Commissioning Prerequisites for the DP Slave
112
Procedure for Commissioning the DP Slave
112
Startup of the IM
113
Startup Behavior in the Case of Module Change During Operation
113
Startup of the IM 153-2/153-2 FO
114
Startup for Time Synchronization/Time Stamping
116
PROFIBUS-DPV1 Mode
117
Comparison between DPV1 and DPV0 Slave
117
Diagnostics Using Leds
119
Status and Error Leds on the IM
119
Status and Error Messages of the IM
120
Diagnostics Using STEP 7 and STEP
122
Displaying the Diagnosis Using STEP STEP 7 and STEP
122
Structure of the Slave Diagnosis
126
With IM 153-2
126
Structure of the Slave Diagnosis
127
Station Statuses 1 to
128
Structure of Station Status 1 (Byte 0)
128
Structure of Station Status 2 (Byte 1)
129
Structure of Station Status 3 (Byte 2)
129
Master PROFIBUS Address
130
Manufacturer ID
130
Structure of the Manufacturer ID (Bytes 4, 5)
130
Structure of the Module Diagnosis
131
Structure of the Module Status for the ET 200M
132
Channel-Specific Diagnosis
133
Structure of the Channel-Specific Diagnosis
134
Channel-Specific Error Messages to PROFIBUS Standard
135
Channel-Specific Error Messages - Manufacturer-Specific
136
H Status (with S7-400H and Standard Redundancy Only)
137
Structure of the H Status of the IM 153-2 (Only for S7-400H)
137
Interrupts
138
Structure of the Interrupt Status of the Interrupt Section
140
Structure of Bytes X+4 to X+7 for Diagnostic Interrupt
141
Structure as of Byte X+8 for Diagnostic Interrupt (Digital Inputs)
142
Structure as of Byte X+8 for Diagnostic Interrupt (Digital Outputs)
143
Structure as of Byte X+8 for Diagnostic Interrupt (Analog Inputs)
144
Structure as of Byte X+8 for Diagnostic Interrupt (Analog Outputs)
145
Structure as of Byte X+4 for Process Interrupt (Analog Inputs)
146
Evaluating Interrupts from the Station Diagnosis
147
Structure as of Byte X+4 for Module Removal/Insertion Interrupt
147
7 Maintenance
150
Replacing the IM
152
Replacing the IM 153-2 or IM 153-2 FO
153
Replacing Modules Without the "Module Change During Operation" Function
157
Removing Modules Without "Module Change During Operation
157
Removing the Front Connector Coding Key
158
Replacing Modules with the "Module Change During Operation" Function
160
Replacing the Bus Module
162
Changing Fuses in Digital Output Modules
163
Location of the Fuses on Digital Output Modules
163
Update of the IM 153-X
165
Update of the IM 153-1/-2Ax0X
165
Update of the IM 153-2Bx00
165
Update Via MMC
169
8 Technical Specifications
170
Standards, Certificates and Approvals
171
Parameters of the IM 153-X
176
Technical Specifications
178
Dimensioned Drawing of the IM 153-1 and IM
180
Basic Circuit Diagram of the IM 153-1 and IM 153-2
180
Basic Circuit Diagram of the IM 153-2 FO
180
Response Time of the ET 200M
181
Identification Data
222
Siemens SIMATIC ET 200M Operating Instructions Manual (274 pages)
Distributed I/O device
Brand:
Siemens
| Category:
I/O Systems
| Size: 6.48 MB
Table of Contents
Direct Data Exchange
11
Enhanced Diagnostics
19
Configurable FM in an ET 200M
19
Redundancy 1
46
Flying Redundancy
164
In the Redundant System
167
In the Non-Redundant System
167
Table of Contents
245
X X X
250
Advertisement
Siemens SIMATIC ET 200M Workshop Manual (14 pages)
Brand:
Siemens
| Category:
Network Hardware
| Size: 1.65 MB
Table of Contents
1 Introduction
5
2 Product Information
7
Supplement to the Sections
7
The New Functions for the IM 153-4
10
Advertisement
Related Products
Siemens SIMATIC NET PROFIBUS
Siemens SIMATIC NET PROFIBUS OBT
Siemens SIMATIC NET SCALANCE W788-1RR
Siemens SIMATIC NET SCALANCE W788-2RR
Siemens SIMATIC NET SCALANCE W747-1RR
Siemens SIMATIC PN/CAN LINK
Siemens SIMATIC NET SCALANCE X-100 Series
Siemens SIMATIC NET RUGGEDCOM APE
Siemens S223
Siemens SANTIS-ab
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL