Sign In
Upload
Manuals
Brands
Siemens Manuals
Measuring Instruments
SITRANS FUP1010
Siemens SITRANS FUP1010 Flowmeter Manuals
Manuals and User Guides for Siemens SITRANS FUP1010 Flowmeter. We have
4
Siemens SITRANS FUP1010 Flowmeter manuals available for free PDF download: Operating Instructions Manual, Quick Start Manual, Quick Start
Siemens SITRANS FUP1010 Operating Instructions Manual (214 pages)
Ultrasonic flowmeters IP67
Brand:
Siemens
| Category:
Measuring Instruments
| Size: 7.79 MB
Table of Contents
Table of Contents
5
FUP1010 IP67 Portable Operating Instructions, 03/2012, A5E02951522-02
9
Introduction
11
Preface
11
Items Supplied
11
History
11
Further Information
12
Safety Notes
13
Laws and Directives
13
Lithium Batteries
14
Certificates
14
Description
15
FUP1010 Features
15
Figure 3-1 Weatherproof Case-Shown Open
15
Applications
16
Theory of Operation
17
Installing/Mounting
23
Installation Safety Precautions
23
Use According to Specifications
23
Application Guidelines
24
AC Battery Charger
24
Figure 4-1 Power Adapter/Battery Charger
25
Table 4- 1 Power Cord Codes
26
Connecting
27
Transmitter Wiring
27
Forming the Internal Battery
27
Connecting AC Power Adapter/Charger
29
Figure 5-1 Power Adapter/Ac-Charger for Dual Channel Flow Meter
29
Sensor Wiring
30
Preliminary Installation Procedures
30
Figure 5-4 Sensor Alignment (Horizontal Plane)
32
Sensor Identification and Selection
33
Navigating the Menu
36
Table 5- 1 Keypad Function Chart
37
Setting the Parameters
38
Table 5- 2 Pipe Configuration Option List Definitions
41
Reflect Mount
43
Figure 5-11 Sensor Mounting with E-Z Clamp and Spacer Bar
45
Figure 5-14 Connecting Sensors to Flow Meter
46
Direct Mount
47
Figure 5-16 EZ Clamping Sensor to Pipe
48
Figure 5-19 Wrapping the Mylar Spacing Guide Around the Pipe (End View)
50
Figure 5-20 Finding the Halfway Distance
51
Figure 5-22 Connecting Sensors to Flow Meter
52
1012T Mounting Tracks
53
Figure 5-23 Reflect Mount with Model 1012TP Mounting Track (Side View)
54
Figure 5-24 Reflect Mode Chain Loop (Front View)
55
Figure 5-25 Direct Mount 180° Opposed with Mounting Tracks
57
Figure 5-26 Direct Mount Roller Chain
59
Figure 5-27 Wrapping the Mylar Spacing Guide Around Pipe (End View)
60
Figure 5-29 Track Rail Alignment
61
Figure 5-30 REF and Number Index Pin Locations
62
Zero Flow Adjust Menu
63
Commissioning
69
General Requirements
69
Empty Pipe Set
70
Installation Menus
74
Functions
79
Selecting Flow Units
79
Table 7- 1 Totalizer Modes
80
Table 7- 2 Totalizer Controls (the "N" in <Fn> = Channel Number)
82
Span Data
83
Logger Control
85
Table 7- 3 Logger Control Menu Option List
85
Operation Adjust Menu Settings
88
Setting Relays
91
Table 7- 4 Relay Option List
91
Memory Control
93
Table 7- 5 Memory Control Menu
93
Analog out Setup
94
Table 7- 6 Analog Outputs
94
Table 7- 7 Analog out Setup Data Categories
94
Analog Input Setup
96
Analog Output Trim
99
Table 7- 8 Analog out Trim Menu Structure
99
RTD Calibration
102
Table 7- 9 RTD Calibrate Menu Structure
103
Reflexor
105
Table 7- 10 Inline Metal and Plastic Pipe Cable Connections
107
Figure 7-2 Adjacent Sensor Mounting
107
Figure 7-4 Spectra Graph Display Screen
111
Table 7- 11 Cursor Definitions
112
Table 7- 12 Diagnostic Data
114
Alarm, Error, and System Messages
117
Alarm Letter Codes
117
Table 8- 1 Alarm Codes and Descriptions
117
Maintenance and Service
119
Maintenance
119
Technical Support
119
Replacing the Battery
120
Figure 9-1 Faceplate Removal
121
Figure 9-2 Battery Cover Removal
122
Battery Disposal
123
Disposal
124
Return Procedures
124
Troubleshooting
125
Table 10- 1 Troubleshooting Tips
125
F4 Reset Procedure
127
Test Facilities Graph Screen
128
Figure 10-2 Setting Digital Damping Factor
132
Figure 10-3 Setting the Mindamp Factor
133
Table 10- 2 Description of Graph Screen Text Display Parameters
136
Table 10- 3 Hot Key Summary
137
Site Setup Data
138
Table 10- 4 Site Setup Menu Items
138
Technical Data
143
Table 11- 1 Performance Specifications
143
Appendix
145
Ordering
145
I/O Connections and Wiring
145
Table A- 1 Part Numbers and Connection Data
145
A.1 Ordering
145
Table A- 2 2 Channel/2 Path Input/Output Terminal Block Wiring
146
Site Setup for SITRANS F
147
Flowrate Calibration and Calibration Tables
154
Appendix
157
Installation/Outline Drawings
157
B.1 Installation/Outline Drawings
157
Glossary
159
Index
209
Advertisement
Siemens SITRANS FUP1010 Operating Instructions Manual (208 pages)
Ultrasonic flowmeters 7ME3510 Portable Flowmeter
Brand:
Siemens
| Category:
Measuring Instruments
| Size: 8.1 MB
Table of Contents
Table of Contents
5
1 Introduction
9
Preface
9
Items Supplied
9
History
9
Connecting
9
Further Information
10
2 Safety Notes
11
Laws and Directives
11
Lithium Batteries
12
3 Description
13
FUP1010 Features
13
Figure 3-1 Weatherproof Case-Shown Open
13
Commissioning
13
Applications
14
Functions
14
Theory of Operation
15
4 Installing/Mounting
21
Installation Safety Precautions
21
Use According to Specifications
21
Application Guidelines
22
Charging the Battery
22
Table 4-1 Power Cord Codes
23
Figure 4-1 Power Adapter/Battery Charger
23
5 Connecting
25
Transmitter Wiring
25
Connecting Battery Power
25
Maintenance and Service
25
Figure 5-1 External Battery Pack
27
Figure 5-2 1015BCK-2 and 1015BCA-2 Battery Chargers
29
Connecting AC Power
30
Sensor Wiring
30
Preliminary Installation Procedures
30
Figure 5-3 Power Adapter/Ac-Charger for Dual Channel Flowmeter
30
Figure 5-4 Reflect Mount (Pipe Shown from above in 12 O'clock Position)
31
Figure 5-5 Direct Mount (Pipe Shown from above in 12 O'clock Position)
32
Figure 5-6 Sensor Alignment (Horizontal Plane)
33
Sensor Identification and Selection
34
Setting the Parameters
35
Table 5-1 Pipe Configuration Option List Definitions
38
Reflect Mount
39
Figure 5-9 Sensor Mounting with E-Z Clamp and Spacer Bar
41
Figure 5-11 Sensor
42
Direct Mount
43
Figure 5-14 EZ Clamping Sensor to Pipe
45
Figure 5-17 Wrapping the Mylar Spacing Guide Around the Pipe (End View)
48
Figure 5-19 Aligning the Sensors for Direct Mode (End View)
49
1012T Mounting Tracks
50
Figure 5-21 Reflect Mount with Model 1012TP Mounting Track (Side View)
52
Figure 5-22 Reflect Mode Chain Loop (Front View)
53
Figure 5-23 Direct Mount 180° Opposed with Mounting Tracks
56
Figure 5-24 Direct Mount Roller Chain
58
Figure 5-25 Wrapping the Mylar Spacing Guide Around Pipe (End View)
59
Figure 5-27 Track Rail Alignment
60
Figure 5-28 REF and Number Index Pin Locations
61
Zero Flow Adjust Menu
62
6 Commissioning
67
General Requirements
67
Navigating the Menu
68
Table 6-1 Key Pad Function Chart
69
Installation Menus
70
7 Functions
75
Selecting Flow Units
75
Table 7-1 Totalizer Modes
76
Table 7-2 Totalizer Controls (the "N" in <Fn> = Channel Number)
77
Span Data
78
Logger Control
80
Table 7-3 Logger Control Menu Option List
80
Operation Adjust Menu Settings
83
Setting Relays
86
Table 7-4 Relay Option List
86
Memory Control
88
Table 7-5 Memory Control Menu
88
Analog Output Setup
89
Table 7-6 Analog Outputs
89
Table 7-7 Analog out Setup Data Categories
89
Analog Input Setup
91
Analog Output Trim
93
Table 7-8 Analog out Trim Menu Structure
93
RTD Calibration
96
Table 7-9 RTD Calibrate Menu Structure
97
Reflexor
98
Figure 7-2 Adjacent Sensor Mounting
101
Table 7-10 Inline Metal and Plastic Pipe Cable Connections
101
Figure 7-4 Spectra Graph Display Screen
106
Table 7-11 Cursor Definitions
107
Table 7-12 Diagnosic Data
109
8 Alarm, Error, and System Messages
111
Alarm Letter Codes and Descriptions
111
Table 8-1 Alarm Codes and Descriptions
111
9 Maintenance and Service
113
Maintenance
113
Replacing the Battery
113
Figure 9-1 Faceplate Removal
114
Figure 9-2 Battery Cover Removal
115
Battery Disposal
116
Technical Support
116
Return Procedures
117
10 Troubleshooting
119
Table 10-1 Troubleshooting Tips
119
F4 Reset Procedure
120
Test Facilities Graph Screen
121
Figure 10-2 Setting Digital Damping Factor
125
Figure 10-3 Setting the Mindamp Factor
126
Table 10-2 Description of Graph Screen Text Display Parameters
129
Table 10-3 Hot Key Summary
129
Site Setup Data
130
Table 10-4 Site Setup Menu Items
131
11 Technical Data
137
Table 11-1 Performance Specifications
137
Appendix
139
Certificates
139
Accessories and Spare Parts
139
I/O Connections and Wiring
139
Table A-1 Part Numbers and Connection Data
139
Table A-2 2 Channel/2 Path Input/Output Terminal Block Wiring
139
A.1 Certificates
139
Site Setup for SITRANS F
140
Flowrate Calibration and Calibration Tables
147
Appendix
151
Installation/Outline Drawings
151
B.1 Installation/Outline Drawings
151
Glossary
153
Index
205
Siemens SITRANS FUP1010 Quick Start Manual (46 pages)
IP67 Portable Ultrasonic Flowmeter
Brand:
Siemens
| Category:
Measuring Instruments
| Size: 1.19 MB
Table of Contents
Table of Contents
5
1 Introduction
7
Items Supplied
7
2 Installation
9
Application Guidelines
9
Figure 2-1 Power Adapter/Battery Charger
10
Forming the Internal Battery
11
Table 2- 1 Power Cord Codes
11
Connecting AC Power Adapter/Charger
13
Figure 2-2 Power Adapter/Ac-Charger for Dual Channel Flow Meter
13
3 Commissioning
15
Connecting AC Power
15
Figure 3-1 Power Adapter/Ac Charger for Single and Dual Channel Flow Meters
15
Navigating the Menu
16
Table 3- 1 Keypad Function Chart
17
Figure 3-2 Keypad
17
Figure 3-3 Typical Installation Menu Screen
18
Setting the Parameters
19
Table 3- 2 Pipe Configuration Option List Definitions
22
Figure 3-4 Universal Sensor Label
24
Figure 3-5 Hi-Precision Sensor Label
25
Sensor Installation
27
General Information
27
Installing the Sensors
27
Figure 3-6 Reflect Mount with Mounting Frames and Spacer Bar (Front View)
28
Figure 3-7 Sensor
30
Figure 3-8 Sensor Installation
30
Final Setup
31
Figure 3-9 Connecting Sensors to Flow Meter
31
Figure 3-10 Final Setup
32
Figure 3-11 Measuring Flow
32
4 Troubleshooting
33
Table 4- 1 Troubleshooting Tips
33
Alarm Codes
35
Appendix
37
I/O Connections and Wiring
37
Table A- 1 Part Numbers and Connection Data
37
Table A- 2 2 Channel/2 Path Input/Output Terminal Block Wiring
38
Table A- 3 Performance Specifications
39
Advertisement
Siemens SITRANS FUP1010 Quick Start (2 pages)
clamp-on non-intrusive ultrasonic flowmeter
Brand:
Siemens
| Category:
Measuring Instruments
| Size: 2.47 MB
Advertisement
Related Products
Siemens SITRANS FUH1010PVX
Siemens FUG1010 IP65 NEMA 4X
Siemens SITRANS FUE950
Siemens FUS1010 IP66 NEMA 7
Siemens SITRANS FUT1010 & IP66 NEMA 7
Siemens FUH1010 IP65 NEMA 7 Compact
Siemens SITRANS FUE1010
Siemens sitrans LU01
Siemens SITRANS F M MAG 1100
Siemens SITRANS F M MAG 3100
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL