Sign In
Upload
Manuals
Brands
Siemens Manuals
Transmitter
SITRANS LR
Siemens SITRANS LR Manuals
Manuals and User Guides for Siemens SITRANS LR. We have
3
Siemens SITRANS LR manuals available for free PDF download: Quick Start Manual, Operating Instructions Manual, Application Examples
Siemens SITRANS LR Quick Start Manual (185 pages)
SITRANS Series Radar Transmitters
Brand:
Siemens
| Category:
Transmitter
| Size: 3.78 MB
Table of Contents
Safety Guidelines
3
Specifications
4
Ambient Operating Temperature
4
Installation
6
Mounting Instructions
7
Connecting SITRANS Probe LR
8
RUN Mode and PROGRAM Mode
9
RUN Mode Display
9
PROGRAM Mode Display
10
Hand Programmer
10
Activating SITRANS Probe LR
11
Accessing a Parameter
11
Changing a Parameter Value
12
Master Reset (P999)
12
Set P003: Measurement Response
13
Select Measurement Units (P005)
13
SITRANS Probe LR Communications: HART
15
Maintenance
15
Instructions Specific to Hazardous Area Installations (Reference European ATEX Directive 94/9/EC, Annex II, 1/0/6)
16
SITRANS Probe LR Kvikstart Manual
19
Tekniske Data
20
Omgivende Temperatur/Driftstemperatur
20
Installation
22
Elektrisk Installation
23
Tilslutning Af SITRANS Probe LR
24
RUN Mode Og PROGRAM Mode
25
Display I RUN Mode
25
Normal Drift
25
Display I PROGRAM Mode
26
Håndholdt Programmeringsenhed
26
Aktivering Af SITRANS Probe LR
27
Adgang Til en Parameter
27
Master Reset (P999)
28
Indstil P001: Drift (Målingsmode)
29
Indstil P003: Målingsrespons
29
Vælg Måleenheder (P005)
29
Indstil Måleområdet (P007: Spændvidde)
30
SITRANS Probe LR Kommunication: HART
31
Reparation Af Instrumentet Og Ansvarsbegrænsning
31
Særlige Anvisninger Vedrørende Installation I Risikoområder (Reference: Det Europæiske ATEX Direktiv 94/9/EF, Bilag II, 1/0/6)
32
SITRANS Probe LR Kurzanleitung
35
Sicherheitstechnische Hinweise
35
Technische Daten
36
Installation
38
Anschluss Hilfsenergie
39
Anschluss des SITRANS Probe LR
40
RUN Modus und PROGRAMMIER-Modus
41
Anzeige IM RUN Modus
41
Anzeige IM PROGRAMMIER-Modus
42
Start des SITRANS Probe LR
43
Zugriff auf einen Parameter
43
Änderung eines Parameterwertes
44
Master Reset (P999)
44
Einstellung P003: Reaktionszeit
45
Einstellung P005: Maßeinheit
45
SITRANS Probe LR Kommunikation: HART
47
Wartung
47
Gerätereparatur und Haftungsausschluss
47
SITRANS Probe LR
67
Indicaciones de Seguridad
67
Especificaciones Técnicas
68
Temperatura Ambiente y de Operación
68
Alimentación Eléctrica
69
Construcción Mecánica
69
Instalación
70
Instrucciones de Montaje
71
Conexión Eléctrica del SITRANS Probe LR
72
Visualización en Modo RUN
73
Visualización en Modo PROGRAM
74
Programador Manual
74
Activación del SITRANS Probe LR
75
Visualizar un Parámetro
75
Modificar el Valor de un Parámetro
76
Programar P003: Tiempo de Respuesta de la Medida
77
Seleccionar la Unidad de Medida (P005)
77
Comunicación SITRANS Probe LR: HART
79
Mantenimiento
79
Instrucciones Específicas Relativas a Instalaciones en Áreas Peligrosas (Directiva Europea ATEX 94/9/CE, Anexo II, 1/0/6)
80
SITRANS Probe LR - Mise en Service Simplifiée
83
Consignes de Sécurité
83
Caractéristiques Techniques
84
Température Ambiante/De Fonctionnement
84
Alimentation Électrique
85
Montage
86
Instructions Pour Le Montage
87
Connexion du Système SITRANS Probe LR
88
MODE RUN Et Mode PROGRAM
89
Affichage en Mode RUN
89
Fonctionnement Normal
89
Affichage en Mode PROGRAM
90
Programmateur Portatif
90
Démarrage du SITRANS Probe LR
91
Accès Aux Paramètres
91
Pour Modifier la Valeur D'un Paramètre
92
Remise À Zéro Générale (P999)
92
Régler P003 : Temps de Réponse de la Mesure
93
Sélectionner L'unité de Mesure
93
Sélectionner L'unité de Mesure (P005)
93
Communication SITRANS Probe LR : HART
95
SITRANS Probe LR
99
Indicazioni DI Sicurezza
99
Caratteristiche Tecniche
100
Temperatura Ambiente/DI Funzionamento
100
Caratteristiche Meccaniche
101
Installazione
102
Istruzioni Generali DI Montaggio
103
Collegamento Elettrico
104
Collegamenti SITRANS Probe LR
104
Modo RUN E Modo PROGRAM
105
Display Nel Modo RUN
105
Funzionamento Normale
105
Visualizzazione in Modo PROGRAM
106
Calibratore Portatile
106
Attivazione SITRANS Probe LR
107
Accesso Ad un Parametro
107
Modifica DI un Valore DI Parametro
108
Reset Generale (P999)
108
Impostare P001: Modo Misurazione
109
Impostare P003: Smorzamento
109
Selezione Unità DI Misura (P005)
109
Impostazione Della Portata DI Misurazione (P007: Campo)
110
Minimizzazione DI Echi Falsi (DI Disturbo) Impostare P838 (Distanza DI Soppressione Automatica DI Echi Falsi)
110
Comunicazione SITRANS Probe LR: HART
111
Manutenzione
111
Istruzioni Specifiche Per Apparecchiature Utilizzate in Zone Potenzialmente Esplosive (Direttiva Europea ATEX 94/9/CE, Allegato II, 1/0/6)
112
SITRANS Probe LR Quick Start Handleiding
115
SITRANS Probe LR
116
Montage-Instructies
119
Aansluiten SITRANS Probe LR
120
RUN Modus en PROGRAM Modus
121
RUN Modus Display
121
PROGRAM Modus Display
122
Activeren Van de SITRANS Probe LR
123
Een Parameter Kiezen
123
Wijzigen Van Een Parameterwaarde
124
Instellen P003: Meetresponsie
125
Kies Meeteenheden (P005)
125
Minimaliseer Ongewenste Reflecties: Stel P838 in (Automatische Stoorecho- Onderdrukkingsafstand)
126
Schakel Foute Echo Onderdrukking In: Stel P837 In, Automatische Onderdrukking Stoorecho
126
SITRANS Probe LR Communicatie: HART
127
Instructies Speciaal Voor Installaties in Explosiegevaarlijke Zones (Raadpleeg de Europese ATEX Richtlijn 94/9/EC, Annex II, 1/0/6)
128
Manual de Partida Rápida Do SITRANS Probe LR
131
Instruções de Segurança
131
SITRANS Probe LR
132
Temperatura Ambiente/De Funcionamento
132
Instruções de Montagem
135
Ligação Do SITRANS Probe LR
136
Modos RUN E PROGRAM
137
Mostrador Do Modo RUN
137
Mostrador de Modo PROGRAM
138
Ativação Do SITRANS Probe LR
139
Acesso a um Parâmetro
139
Alteração de um Valor de Parâmetro
140
Rearme Principal (P999)
140
Seleccionar Idioma (P010: Idioma)
140
Definir P003: Measurement Response (Resposta de Medição)
141
Selecção das Unidades de Medição (P005)
141
Comunicações Do SITRANS Probe LR: HART
143
Instruções Específicas para Instalações Em Zonas Perigosas (Referência Directiva Europeia ATEX 94/9/CE, Anexo II, 1/0/6)
144
SITRANS Probe LR Pikakäyttöopas
147
Tekniset Tiedot
148
Ympäristön Lämpötila/Käyttölämpötila
148
Mekaaniset Tiedot
149
SITRANS Probe Lr:n Kytkeminen
152
RUN- Ja PROGRAM-Tilat
153
RUN-Käyttötilan Näyttö
153
PROGRAM-Ohjelmointitilan Näyttö
154
SITRANS Probe Lr:n Aktivointi
155
Parametrin Haku
155
Parametriarvon Muuttaminen
156
Kaikkien Arvojen Palauttaminen (P999)
156
Aseta P003-Parametri: Mittausvastinnopeus
157
Valitse Mittayksikkö (P005)
157
Aseta Mittausalue (P007: Ääritaso)
158
Palaa RUN-Käyttötilaan
159
SITRANS Probe LR -Laitteen Tiedonsiirto: HART
159
Laitteen Korjaaminen Ja Vastuuvapauslauseke
159
Räjähdysvaarallisten Tilojen Asennusta Koskevat Ohjeet (ATEX-Direktiivi 94/9/EY, Liite II, Kohta 1/0/6)
160
SITRANS Probe LR Manual För Snabbstart
163
Riktlinjer För Säkerhet
163
Rums- Och Arbetstemperatur
164
Instruktioner För Montering
167
Hur du Ansluter SITRANS Probe LR
168
RUN-Läge Och PROGRAM-Läge
169
Display För PROGRAM Arbetssätt
170
Aktivering Av SITRANS Probe LR
171
Tillträde Till en Parameter
171
Ändring Av Parametervärde
172
Ställ in P003: Mätningssvar
173
Välj Mätenheter (P005)
173
Instruktioner Som Gäller Installation På Riskabla Platser (Referens: Europeiska ATEX-Direktivet 94/9/EC, Bilaga II, 1/0/6)
176
Appendix A: Connection Drawings and Loop Power Curve
179
Wiring Drawing: Non-Incendive (FM)
179
Wiring Drawing: Intrinsically Safe (FM )
180
Wiring Drawing: Intrinsically Safe (CSA)
181
Loop Power
182
Loop Voltage Versus Loop Resistance
182
For more Information
184
Advertisement
Siemens SITRANS LR Operating Instructions Manual (111 pages)
Radar Transmitters, Probe with mA/HART
Brand:
Siemens
| Category:
Measuring Instruments
| Size: 1.41 MB
Table of Contents
Table of Contents
3
1 Introduction
8
Purpose of this Documentation
8
Checking the Consignment
8
Industrial Use
8
Product Compatibility
9
Security Information
9
Transportation and Storage
10
Notes on Warranty
10
2 Safety Notes
11
Preconditions for Use
11
Safety Marking Symbols
11
Laws and Directives
11
Industry Canada Conformity
12
Conformity with European Directives
12
Radio Equipment Directive (RED) Compliance (Europe)
13
FCC Conformity
13
CE Electromagnetic Compatibility (EMC) Conformity
14
Use in Hazardous Areas
14
Loss of Safety of Device with Type of Protection "Intrinsic Safety Ex I
15
3 Description
16
SITRANS Probe LR
16
SITRANS Probe LR System Implementation
17
4 Installing/Mounting
18
Basic Safety Notes
18
Incorrect Disassembly
18
Installation Notes
19
Nozzle Location
21
Nozzle Design
21
Mounting Instructions
22
5 Connecting
23
Power
23
Connecting SITRANS Probe LR
23
Nameplates for Hazardous Area Installations
24
FM and CSA Connection Drawings
25
6 Commissioning
26
Basic Safety Notes
26
Local Commissioning
26
Activating SITRANS Probe LR
26
Operating SITRANS Probe LR
26
Low Temperature Effects on RUN/PROGRAM Modes
27
RUN Mode
27
PROGRAM Mode
28
Handheld Programmer Functions
28
Handheld Programmer
29
Handheld Programmer: Function Keys in PROGRAM Mode
30
Handheld Programmer: Function Keys in RUN Mode
31
Accessing a Parameter
31
Security
33
Changing a Parameter Value
33
Master Reset
33
Using Units or Percent (%)
34
Quick Start Wizards
34
Quick Setup for Local Operation (Outline)
34
P001: Operation
35
P003: Measurement Response
36
P005: Units
36
P006: Empty
36
P007: Span
37
P010: Language
38
P838 Auto False Echo Suppression
38
Additional Settings
39
7 Parameter Assignment
40
P000 Lock
41
Quick Start (P001 to P010)
42
P003 Measurement Response
43
P004 Antenna Type
44
P005 Units
44
P006 Empty (Process Empty Level)
44
P007 Span (Process Full Level)
45
P010 Language
46
P050 to P055 Volume
46
P050 Vessel Shape
46
P051 Maximum Volume
48
P052 Vessel Dimension a
48
P053 Vessel Dimension L
49
P054 Level Breakpoints
49
P055 Volume Breakpoints
50
P069 Unlocked Value
51
Failsafe (P070 to P073)
52
P070 Failsafe Timer
52
P071 Failsafe Material Level
52
P073 Failsafe Level
52
Ma Output (P201 to P215)
53
P201 Ma Output Function
53
Independent Ma Setpoint Parameters (P210 and P211)
53
P210 4 Ma Setpoint (Low Output)
54
P211 20 Ma Setpoint (High Output)
55
Ma Output Limit Parameters (P212 and P213)
55
P212 Minimum Ma Limit
55
P213 Maximum Ma Limit
55
P214 4 Ma Output Trim
56
P215 20 Ma Output Trim
56
Installation Records (P341 to P346)
56
P341 RUN Time
56
P342 Power-On Resets
57
P343 Internal Temperature
57
P346 Serial Number
57
Range Calibration (P652 to P655)
57
P652 Offset Correction
58
P655 Propagation Factor
58
Rate (P700 and P701)
59
P700 Maximum Fill Rate
59
P701 Maximum Empty Rate
59
Measurement Verification (P709 to P713)
60
P709 Damping Filter
60
P711 Echo Lock
60
P712 Echo Lock Sampling
61
P713 Echo Lock Window
62
P752 HART Address
63
Communications (P799)
63
P799 Communications Control
63
Echo Processing (P800 to P807)
63
P800 Near Blanking
64
P801 Range Extension
64
P804 Confidence Threshold
64
P805 Echo Confidence
65
P806 Echo Strength
65
P807 Noise
65
Algorithm (P820)
65
P820 Echo Algorithm
65
TVT (Time Varying Threshold) Adjustment Parameters (P831 to P839)
66
P831 Manual TVT Shaper
66
P832 Manual TVT Shaper Adjust
66
P837 Auto False Echo Suppression
66
P838 Auto False Echo Suppression Distance
67
P839 TVT Hover Level
69
Test (P900 to P924)
69
P900 Software Revision Number
69
P901 Memory Test
69
Measurement
69
P911 Ma Output Value (Hart/Ma Only)
69
P920 Reading Measurement
70
P921 Material Measurement
70
P922 Space Measurement
70
P923 Distance Measurement
70
P924 Volume Measurement
70
P999 Master Reset
71
8 Service and Maintenance
72
Maintenance and Repair Work
72
Return Procedure
72
Disposal
73
9 Troubleshooting
74
General Fault Codes
74
Fault Codes (Firmware Revision 3.02 or Higher)
74
Fault Codes (Firmware Revision 1.05 or Earlier)
76
Operation Troubleshooting
78
10 Technical Data
80
Power
80
Performance
81
Construction
82
Operating Conditions
82
Process
82
Approvals
83
11 Dimension Drawing
84
SITRANS Probe LR Dimensions
84
Technical Reference
86
Principles of Operation
86
Transceiver
86
Near Blanking
87
Loss of Echo (LOE)
87
Range Extension
88
False-Echo Suppression
88
TVT (Time Varying Threshold) Curves
88
Auto False-Echo Suppression
88
Output
90
Failsafe
91
Chemical Compatibility
91
HART Communication
92
HART Communication for SITRANS Probe LR
92
HART Electronic Device Description (EDD)
92
SIMATIC Process Device Manager (PDM)
92
Maintenance Settings (Accessible Via PDM Only)
93
HART Version
93
Burst Mode
93
Application Examples
94
Application Examples Introduction
94
Example 1: Liquid Resin in Storage Vessel, Level Measurement
94
Example 2: Horizontal Vessel with Volume Measurement
96
Hazardous Area Installations
98
Wiring Details
98
Fm/Csa
98
EU Equivalency
99
Loop Voltage Versus Loop Resistance
100
IS Safety Barrier Selection
100
Instructions Specific to Hazardous Area Installations (Reference European ATEX Directive 2014/34/EU Annex II, 1/0/6)
102
Certificates and Support
103
Technical Support
103
Certificates
103
Glossary
104
Index
109
Siemens SITRANS LR Application Examples (11 pages)
Using SITRANS LR in a Stilling Well
Brand:
Siemens
| Category:
Measuring Instruments
| Size: 0.49 MB
Table of Contents
Table of Contents
3
Introduction
4
Objective
4
Disclaimer
4
Applications
5
Advantages
6
Guidelines
7
Radar Installation and Commissioning Requirements
9
Propagation Factor
10
Using the CLEF Position Detect Parameter for Optimum Accuracy
11
Advertisement
Advertisement
Related Products
Siemens SITRANS LR250 PROFIBUS PA
Siemens SITRANS TW
Siemens sitrans PROBE LU
Siemens SITRANS P series
Siemens SITRANS P ZD Series
Siemens SITRANS P DS III Series
Siemens SITRANS T Series
Siemens SITRANS Series
Siemens SITRANS Probe LR with mA/HART
Siemens SITRANS TH Series
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL