Sign In
Upload
Manuals
Brands
Siemens Manuals
Accessories
SITRANS WM300 MFA
Siemens SITRANS WM300 MFA Manuals
Manuals and User Guides for Siemens SITRANS WM300 MFA. We have
2
Siemens SITRANS WM300 MFA manuals available for free PDF download: Operating Instructions Manual
Siemens SITRANS WM300 MFA Operating Instructions Manual (82 pages)
Motion Sensors
Brand:
Siemens
| Category:
Accessories
| Size: 2.31 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Purpose of this Documentation
7
Document History
7
FW Revision History
7
Checking the Consignment
8
Unit Repair and Excluded Liability
8
2 SITRANS WM300 MFA Overview
9
3 Installing/Mounting
11
Safety Note
11
Location Requirements
11
Proper Mounting
12
Mounting Details
13
Wiring
16
4 Connecting
19
Interconnection
19
MSP-3 or MSP-9 Probe with RMA (Remote Mounted Amplifier)
19
MSP-12 Probe with RMA (Internally Mounted Pre-Amplifier)
20
XPP-5 with RMA (Internally Mounted Pre-Amplifier)
21
MSP-7 with IMA (Internally Mounted Pre-Amplifier)
22
Cable Length from RMA or IMA to WM300 MFA
23
Interconnection Diagram for XPP-5
24
Connection to Power
26
5 Service and Maintenance
29
Setup
29
Calibration
29
Maintenance
29
6 Parameter Assignment
31
Menu Structure
31
Motion Failure Alarm
32
6.3 Start up Delay
34
Start up Delay (P001)
34
Start up Delay (P002)
35
Alarm Delay
36
Alarm Delay (P003)
36
Alarm Delay (P004)
37
Slow Speed
38
Slow Speed (P005)
38
Slow Speed (P010)
38
Slow Speed (P011)
39
Slow Speed (P012)
40
Slow Speed (P013)
41
Process Variable Overview Display
42
Standard Version Motion Failure Alarm
43
Standard Speed (P020 - P021)
43
Standard Speed (P022 - P023)
44
6.6 Tachometer Function
45
Tachometer Function (P031 - P032)
45
Non-Contacting Tachometer (P030)
46
Differential Speed Detection
46
Differential Speed Detection (P040)
46
Maximum Frequency Setpoint (P041 - P042)
47
Differential Alarm Setpoints (P043 - P044)
49
Operator Display
50
7 Troubleshooting
53
8 Technical Data
55
Safety Note
55
Power
55
Outputs
55
Inputs
56
Performance
56
Design
57
Approvals
57
Operating Conditions
57
9 Dimension Drawings
59
SITRANS WM300 MFA Dimensions
59
High Temperature Probe MSP-3
61
Stainless Steel Probe MSP-9
62
Standard Probe MSP-12 and MSP-7
63
Hazardous Locations XPP-5
64
Technical Reference
67
Principles of Operation
67
A.1 Principles of Operation
67
Applications
71
Bucket Elevators
71
Bucket Elevator
72
B.2 Bucket Elevator
72
Shafts
73
B.3 Shafts
73
Rotating Shaft of Rotary Feeder
74
Drive Sprocket on Rotary Feeder
74
Belt Conveyors
75
Screw Conveyors
75
B.6 Belt Conveyors
75
Screw Conveyor Flights
76
End Bearing on Screw Conveyor
76
Non-Ferrous Window
77
Support
79
Technical Support
79
Certificates
79
C.1 Technical Support
79
Index
81
Advertisement
Siemens SITRANS WM300 MFA Operating Instructions Manual (75 pages)
Motion Sensors
Brand:
Siemens
| Category:
Security Sensors
| Size: 4.84 MB
Table of Contents
Table of Contents
3
Introduction
6
Purpose of this Documentation
6
Document History
6
FW Revision History
6
Checking the Consignment
7
Unit Repair and Excluded Liability
7
SITRANS WM300 MFA Overview
8
Installing/Mounting
9
Safety Note
9
Location Requirements
9
Proper Mounting
10
Mounting Details
11
Wiring
14
Connecting
17
Interconnection
17
MSP-3 or MSP-9 Probe with RMA (Remote Mounted Amplifier)
17
MSP-12 Probe with RMA (Internally Mounted Pre-Amplifier)
18
XPP-5 with RMA (Internally Mounted Pre-Amplifier)
19
MSP-7 with IMA (Internally Mounted Pre-Amplifier)
20
Cable Length from RMA or IMA to WM300 MFA
21
Interconnection Diagram for XPP-5
22
Connection to Power
23
Service and Maintenance
25
Setup
25
Calibration
25
Maintenance
25
Parameter Assignment
26
Menu Structure
26
Motion Failure Alarm
27
Startup Delay
29
Start up Delay (P001)
29
Start up Delay (P002)
30
Alarm Delay
31
Alarm Delay (P003)
31
Alarm Delay (P004)
32
Slow Speed
33
Slow Speed (P005)
33
Slow Speed (P010)
34
Slow Speed (P011)
35
Slow Speed (P012)
36
Slow Speed (P013)
37
Process Variable Overview Display
38
Standard Version Motion Failure Alarm
39
Standard Speed (P020 - P021)
39
Standard Speed (P022 - P023)
40
6.6 Tachometer Function
41
Tachometer Function (P031 - P032)
41
Non-Contacting Tachometer (P030)
42
Differential Speed Detection
43
Differential Speed Detection (P040)
43
Maximum Frequency Setpoint (P041 - P042)
44
Differential Alarm Setpoints (P043 - P044)
46
Operator Display
47
Troubleshooting
49
Technical Specifications
50
Safety Note
50
Power
50
Outputs
50
Inputs
51
Performance
52
Design
53
Approvals
53
Operating Conditions
53
Dimension Drawings
54
SITRANS WM300 MFA Dimensions
54
High Temperature Probe MSP-3
56
Stainless Steel Probe MSP-9
57
Standard Probe MSP-12 and MSP-7
58
Hazardous Locations XPP-5
59
Technical Reference
60
Principles of Operation
60
Applications
64
Bucket Elevators
64
Bucket Elevator
65
Shafts
66
Rotating Shaft of Rotary Feeder
67
Drive Sprocket on Rotary Feeder
67
Belt Conveyors
68
Screw Conveyors
68
Screw Conveyor Flights
69
End Bearing on Screw Conveyor
69
Non-Ferrous Window
70
Product Documentation and Support
71
Product Documentation
71
Technical Support
72
Index
73
Advertisement
Related Products
Siemens Sitrans WM100
Siemens WiPS-200 Series
Siemens SIWAREX WP321
Siemens SIWAREX WP241
Siemens SITRANS WFS320
Siemens SIWAREX WP251
Siemens SITRANS WS300
Siemens SITRANS WW100
Siemens RUGGEDCOM WIN7018
Siemens SIWAREX WL250 ST-S SA
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL