Nokia Customer Care
Page 4–8
MJ-47
MJ-47 is meant for component level troubleshooting.
The jig includes an RF interface for GSM, WCDMA and Bluetooth. In
addition, it has the following features:
• Provides mechanical interface with the engine module
• Provides galvanic connection to all needed test pads in module
• Multiplexing between USB and FBUS media, controlled by Vusb
• UI test interface
• MMC interface
• Duplicated SIM connector
• Audio components: IHF, MIC, earpiece
• Connector for control unit
• Access for Pop-Port
Note:
In the picture CU-4 is connected to MJ-47 . CU-4 is not part
of the MJ-47 sales package and has to be ordered separately.
PCS-1
The PCS-1 power cable (DC) is used with a docking station, a module jig
or a control unit to supply a controlled operating voltage.
PKD-1
SW security device is a piece of hardware enabling the use of the service
software when connected to the parallel (LPT) port of the PC.
Without the device, it is not possible to use the service software.
Printer or any such device can be connected to the PC through the device
if needed.
RJ-56
RJ-56 is a rework jig used with ST-21.
Company Confidential
Copyright ©2005 Nokia. All Rights Reserved.
Service Tools and Service Concepts
Module jig
TM
system connector
Power cable
SW security device
Rework jig
RM-57/58
Issue 1