Related
Path
3.4.4.7.13 Simulation alarms (1)
Description
Selection of alarm items that impact the output. Mainly simulation alarms. Applicable if
Status mode = Alarm item.
Setting
Default
Related
Path
3.4.4.7.14 Simulation alarms (2)
Description
Simulation alarms (2)
Setting
Default
Related
Path
3.4.4.7.15 Alarm class
Description
Selection of alarm classes which impact the status output. Each diagnostic event is allocated
to an alarm class. Applicable if Status mode = Alarm class and status icons = Standard
Bit 0: Process value alarm (PA)
Bit 1: Process value warning (PW)
Bit 2: Maintenance alarm (MA)
Bit 3: Maintenance warning (MW)
FST030
Function Manual, 04/2017, A5E35693328-AA
Setup → Inputs and outputs → Channel 2 - output → Status output → Input/output alarms (2)
160 Mass flow simulated; 161 Volume flow simulated; 162 Density simulated; 163 Medium
temp. simulated; 167 Totalizer 1 simulated; 168 Totalizer 2 simulated; 169 Totalizer 3
simulated; 170 Loop current simulated
None
Setup → Inputs and outputs → Channel 2 - output → Status output → Simulation alarms (1)
289 Sound velocity simulated; 290 Flow velocity simulated; 291 Pressure simulated; 292
Kin. viscosity simulated; 293 Aux. temperature simulated; 294 Sensor temperature simu-
lated; 296 CH5 simulated; 297 CH6 simulated; 298 Std. volume flow simulated; 299
Standardizing factor simulated; 300 Std. kin. viscosity simulated; 301 Std. density simulat-
ed; 303 API gravity simulated; 304 Std. API gravity simulated; 305 Specific gravity simulat-
ed; 306 Std. spec. grav. simulated
None
Setup → Inputs and outputs → Channel 2 - output → Status output → Simulation alarms (2)
Setup
3.4 Inputs and outputs
129