Power
The base requires 12 Volts DC input for communications, battery charging, and power output to the ter-
minal; the power adapter included with the base converts the voltage from the AC power source to 12
Volts DC. Use only the Honeywell 12VDC, 3A power supply provided with the base. The operating tem-
perature range is -10° to 45° C (14° to 113° F).
Honeywell recommends that you leave the base connected to its power source at all times, so that it is
always ready to use.
1. Connect the power cable to the DC jack on the rear panel of the base.
2. Connect the power cable to the power adapter.
3. Plug the power adapter cable into the power source. The base is now powered.
Serial Connector
The following diagram displays the pin diagram of the serial connector of the base.
Pin
Description
1
Internal Jumper to Pin 6
2
TXD
3
RXD
4
No Connect
5
GND
6
DTR
7
CTS
8
RTS
9
RI
Note: The signal names are referenced to the terminal. The terminal is a DCE RS232 device. Refer to section,
RS232 Communications Cables and RS232 Pin Configuration for more details. The base is at a right-angle
to the printed circuit board (PCB). The ninth pin has a ring indicator (RI).
Preliminary Draft 1/19/11
12 - 5