Siemens AR6111-MX Installation Manual
Siemens AR6111-MX Installation Manual

Siemens AR6111-MX Installation Manual

Advertisement

Card reader
AR6111-MX
Installation
Clock/Data Interface Omron and Wiegand
Fire & Security Products
Siemens Building Technologies

Advertisement

Table of Contents
loading

Summary of Contents for Siemens AR6111-MX

  • Page 1 Card reader AR6111-MX Installation Clock/Data Interface Omron and Wiegand Fire & Security Products Siemens Building Technologies...
  • Page 2: Safety Regulations And Warnings

    Introduction Thank you for deciding to purchase the AR6111-MX. The ID card reader AR6111-MX in a wall switch housing is part of the new Access reader range. The reader reads proximity ID cards of 13.56 MHz technologies: ISO14443 Type A - like Mifare® 1k, 4k or UltraLight, my-D proximity (SLE55Rxx),...
  • Page 3 (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Siemens Building Technologies AR6111-MX-Manual.doc Fire & Security Products 02.2003...
  • Page 4: Technical Specifications

    1 x LED red 1 x LED green 1 x beeper Digital Inputs 4 (maximum cable length 3 m) Interfaces: Clock / Data - Magnetic stripe format - Wiegand RS232-TTL (for service only) Siemens Building Technologies AR6111-MX-Manual.doc Fire & Security Products 02.2003...
  • Page 5: Installation

    The clearance to such surfaces should be at least 30 cm. The distance between readers of the same design should not be less than 30 cm. Before final installation, the planned installation site should be checked for suitability. Siemens Building Technologies AR6111-MX-Manual.doc Fire & Security Products...
  • Page 6: Connecting The Reader

    *) If an external power supply is used the ground signal from the power supply and the host must be connected. **) The digital inputs can only be connected to Ground. Any connection to external voltage might damage the unit! Siemens Building Technologies AR6111-MX-Manual.doc Fire & Security Products 02.2003...
  • Page 7 If the Transponder data length doesn't match to the reader configuration the beeper indicates an error by a short double beep. In the case no data's are send out at the clock/data interface. Siemens Building Technologies AR6111-MX-Manual.doc Fire & Security Products...
  • Page 8 Siemens Building Technologies Fire & Security Products GmbH & Co. oHG © 2005 Copyright by D-76181 Karlsruhe Siemens Building Technologies AG Data and design subject to change without notice. Supply subject to availability. www.sbt.siemens.com Printed in the Federal Republic of Germany on environment-friendly chlorine-free paper.