hit counter script
Siemens SIMATIC IPC627E Operating Instructions Manual

Siemens SIMATIC IPC627E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC627E:
Table of Contents

Advertisement

Quick Links

SIMATIC
Industrial PC
SIMATIC IPC627E
Operating Instructions
12/2018
A5E44297201-AA
Preface
___________________
Product description
___________________
Safety instructions
___________________
Installing and connecting the
device
___________________
Commissioning the device
___________________
Operating the device
___________________
Expanding and assigning
parameters to the device
Device maintenance and
repair
___________________
Technical specifications
___________________
Dimension drawings
___________________
Standards and approvals
___________________
Hardware description
___________________
Technical support
___________________
Markings and symbols
___________________
List of abbreviations
1
2
3
4
5
6
7
8
9
10
A
B
C
D

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC627E

  • Page 1 Preface ___________________ Product description ___________________ SIMATIC Safety instructions ___________________ Installing and connecting the device Industrial PC SIMATIC IPC627E ___________________ Commissioning the device ___________________ Operating the device Operating Instructions ___________________ Expanding and assigning parameters to the device Device maintenance and repair...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    General knowledge in the field automation control engineering is recommended. Scope of the operating instructions These operating instructions are valid for all order versions of the SIMATIC IPC627E. History The following editions of these operating instructions have already been published:...
  • Page 4 Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 5: Table Of Contents

    Installing the device with the vertical mounting kit for PC port access from the front .... 44 Connecting the device ......................45 3.3.1 Country-specific information on supply voltage ..............45 3.3.2 Connection of equipotential-bonding cable ................46 SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 6 Opening the Device ....................... 71 Expansion cards ........................73 6.2.1 Usable expansion cards ......................73 6.2.2 Installing/removing expansion cards ..................74 Memory modules........................76 6.3.1 Usable memory modules ....................... 76 6.3.2 Installing and removing memory module ................77 SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 7 Technical specifications of the drives ................... 116 Technical specifications of the motherboard ................ 117 Technical specifications of graphic ..................118 Technical specifications of the interfaces ................118 8.10 Technical specifications of the operating systems ............... 119 SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 8 Table of contents Dimension drawings ..........................121 Dimension drawings of SIMATIC IPC627E (2 expansion slots) .......... 121 Dimension drawings of SIMATIC IPC627E (5 expansion slots) .......... 125 Dimension drawing of the expansion cards ................. 129 Standards and approvals ........................131 10.1...
  • Page 9 Markings and symbols ........................... 155 Overview ..........................155 Safety ............................ 155 Operator controls ........................155 Certificates, approvals and markings ..................156 Interfaces ..........................157 List of abbreviations ..........................159 Abbreviations ........................159 Index ..............................161 SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 10 Table of contents SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 11: Product Description

    Windows® operating Information on: Supplied data storage medium • system Commissioning the operating • Online at: • system Microsoft® Windows® 10 Restoring the operating system • (https://support.industry.siemens. Configuration of the operating • com/cs/ww/en/view/109749498) system SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 12 Online at: • Partition Creator SIMATIC IPC Image Partition Backup and recovery of files, • Creator directories, drive partitions. (https://support.industry.siemens. com/cs/de/en/view/21766418) SIMATIC NET Industrial communication Online at: • SIMATIC NET (http://w3.siemens.com/mcms/aut omation/en/industrial- communications/Pages /Default.aspx) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 13: Product Highlights

    Product description 1.2 Product highlights Product highlights The SIMATIC IPC627E is a powerful industrial PC. It is perfectly suited for PC applications with high-level industry functionality. Device view Note Depending on the configuration ordered the features and illustrations described in this manual may differ from the features of your device.
  • Page 14 ● Fast restoration of delivery state of the operating system (with supplied data storage medium) ● Gbit LAN with teaming capability (3 x LAN 10/100/1000 Mbps connections) ● Service-friendly equipment design (modifications, service) ● Can be used flexibly in a wide variety of positions SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 15: Applications

    The SIMATIC IPC has CE certification for use in the industrial sector as well as in residential and commercial areas and small businesses. In addition to the industrial applications, therefore, it can also be used in building automation or in public facilities. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 16: External Design Of The Device

    X2P1, center: RJ45 Ethernet port 2 (shared PCI interrupt) with 10/100/1000 Mbps • X3PI, right: RJ45 Ethernet port 3 (shared PCI interrupt) with 10/100/1000 Mbps • ⑦ 2 × USB USB 3.1 Gen. 2 Type C high current, backward compatible with USB 3.0/2.0/1.1 X61/X63 SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 17 "-)" symbol is pressed inward on the device. Position "OFF" is the delivery state. ⑫ PCI/PCIe expansion 2 slots for expansion cards (Slot1/X101, Slot2/X102) cards, USB on expansion card (optional) ⑬ Fixing screws for strain relief SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 18 2 × USB USB 3.1 Gen. 2 Type C high current, backward compatible with USB 3.0/2.0/1.1 X61/X63 ⑧ 2 × USB USB 3.1 Gen. 2 Type A high current, backward compatible with USB 3.0/2.0/1.1 X60/X62 SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 19 USB on expansion card (optional) ⑬ Fixing screws for strain relief Device with USB expansion (optional) ⑫ The following expansion cards are located at the position of the cover in the figure above: ① X66, X67 SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 20: Rear Of The Device

    Product description 1.4 External design of the device 1.4.2 Rear of the device ① Removable drives Slots for removable drives ② RAID status indicators HDD alarm ③ Battery compartment CMOS backup battery ④ SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 21: Status Displays

    "Buffer memory NVRAM (optional) (Page 69)". Example programs for controlling the LEDs under Windows operating systems are available on the Internet at the following address: Technical support (https://support.industry.siemens.com/cs/ww/en/) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 22 Both flash RAID is synchronized Status display of Ethernet ports Status display Status Meaning of the status LED 1 10 Mbps Lit green 100 Mbps Lit orange 1000 Mbps LED 2 Connection exists Flashes Activity SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 23: Internal Design Of The Device

    100-240 V AC power supply ② Slots for removable drives ③ Expansion card slots ④ Heat sink of the processor ⑤ Expansion card slots ⑥ Motherboard ⑦ Slots for memory modules ⑧ Retainer for expansion cards SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 24: Accessories And Spare Parts

    Accessories and spare parts 1.6.1 Accessories: Hardware Accessories from Siemens are available for your device that are not included in the scope of delivery. Obtaining accessories and original spare parts via the SIEMENS Industry Mall 1. On the Internet, go to Industry Mall (https://mall.industry.siemens.com).
  • Page 25: Accessories: Software

    Processors of the type i7 offer iAMT functionality. Further information on the software products and references to the online catalog and ordering system (Industry Mall (https://mall.industry.siemens.com)) can be found on the SIMATIC IPC software (http://www.automation.siemens.com/mcms/pc-based- automation/en/industrial-pc/expansion_components_accessories) homepage.
  • Page 26 Product description 1.6 Accessories and spare parts SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 27: Safety Instructions

    • For control cabinet mounting: Use a central, easily accessible AC circuit breaker close to the device, if possible. • When you install the device, make sure that the power supply connector is easily accessible. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 28 Electrostatic sensitive devices (ESD) The device contains electronic components which may be destroyed by electrostatic charge. This can result in malfunctions and damage to the machine or plant. Take corresponding precautionary measures before you open the device. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 29: Note On Transport And Storage

    • Bring the device to room temperature before starting it up. • Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 30: Notes On Mounting

    If the following conditions for system installation are not observed, approvals in accordance with UL 61010-2-201 and EN 61010-2-201 are rendered void and there is a risk of overheating and personal injury. • You should observe the following information on ambient and environmental conditions. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 31 UL 61010-2-201 is therefore a requirement for approval or operation. ● Always maintain a minimum clearance of 100 mm to the area of the ventilation slots and do not cover the ventilation slots of the enclosure. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 32 • Switch off radiating devices. • Reduce the radio output of radiating devices. • Read the information on electromagnetic compatibility. • Read the information in the technical specifications. See also Mounting positions (Page 41) Ambient conditions (Page 116) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 33: Information On I/O Devices

    • The IPC in question must be turned off and the power supply connector must be plugged • During the measurement, all cables from the plant to the IPC should be connected. • All other components in the plant must be active. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 34: Notes On Device And System Extensions

    ● UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". ● We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 35: Installing And Connecting The Device

    On the supplied data medium (read-only), you can find: ● Software and tools to restore your ordered Microsoft® Windows® operating system. ● Device drivers for installation in operating systems ● SIMATIC IPC627E Quick Install Guide ● SIMATIC IPC627E operating instructions ● Product information ●...
  • Page 36 You will find the latest information on additional software for your device under: Accessories and spare parts (Page 24) Printed documents ● SIMATIC IPC627E Quick Install Guide ● Product Information "Important notes on your device" ● SIMATIC IPC/PG Quality Control Report...
  • Page 37: Checking The Delivery Package

    Quality Control Report". 5. Please keep the documentation in a safe place. It is required for initial commissioning and is part of the device. 6. Note down the Identification data of the device (Page 38). SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 38: Identification Data Of The Device

    The following illustrations are examples. The data of your device may differ from the data in these examples. Nameplate The following image shows the nameplate on the SIMATIC IPC627E as an example. COA label The COA label (Certificate of Authenticity) is located on the rear of the device.
  • Page 39: Installing The Device

    Incorrect fixing elements The device may not be securely fitted if you use screws other than those specified below for mounting. The device can fall and may be damaged. • Use only the specified screws. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 40 50 mm long Metal 5 mm diameter Metal screws: 4 mm diameter; (at least 2 mm thick) at least 15 mm long See also Ambient conditions (Page 116) Mounting positions (Page 41) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 41: Mounting Positions

    An inclination of ±15° is allowed in this mounting position. Position 4 (interfaces facing down) Position 5 (interfaces facing up) See also Notes on ambient and environmental conditions (Page 30) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 42: Installation Of The Device With Wall Mounting Rails

    2. Secure the wall mounting rails to the device using the following number of screws: – SIMATIC IPC627E: Six M4 screws; torque 3 Nm SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 43: Installing The Device With The Vertical Mounting Kit

    2. Secure the vertical mounting plate to the device using the following number of screws: – SIMATIC IPC627E: Four or 7 M4 screws; torque 3 Nm ① Remove the screw and the toothed lock washer and fasten them again after installing the vertical mounting plate.
  • Page 44: Installing The Device With The Vertical Mounting Kit For Pc Port Access From The Front

    See the notes under "Mounting positions (Page 41)". Securing the vertical mounting plate to the device Secure the vertical mounting plate on the device using five M4 screws. Two screws at the top and two at the bottom of the device. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 45: Connecting The Device

    Power cords and device connectors must be certified or approved by a recognized testing authority in the respective country and must bear the corresponding prescribed markings. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 46: Connection Of Equipotential-Bonding Cable

    2. Connect the equipotential bonding cable with the central grounding point of the control cabinet. Make sure that the equipotential bonding cable is in contact with the central grounding point over a wide area. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 47: Connecting The Power Supply

    • When you install the device, make sure that the power supply connector is easily accessible. Note The varying voltage power supply module is designed for operation on 120/230/240 V AC networks. The setting of the voltage range takes place automatically. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 48 2. Connect the appliance connector to the device. 3. If necessary, install the enclosed cable grip. 4. Connect the power cable with the safety power outlet. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 49: Connecting The 24 Vdc Power Supply

    ● You have observed the information under "Country-specific information on supply voltage (Page 45)". ● The 24 V DC power source must be adapted to the input data of the device (see Technical specifications (Page 109)). SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 50 The 24 V DC power supply is protected against polarity reversal. When you confuse the 24 V DC connecting cables and ground, the device is not damaged but does not switch on. After the power supply has been connected correctly, the device will again be ready to operate. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 51: Connecting I/O Devices

    1. Connect the I/O devices to the respective interfaces. Information on the position of the interfaces is available in "Front panel (Page 16)". 2. Secure the cables with the strain relief. See: Connecting Ethernet/USB strain relief (Page 54) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 52 The following table shows the various connection options for the monitors on the device interfaces. Motherboard DPP1 DPP2 DVI-D Monitor 1 Monitor 2 Monitor 3 1) - via DP to DVI-D adapter 2) - via DP-VGA adapter SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 53: Connecting The Device To Networks

    You need the "SOFTNET S7" software package for this. PROFINET PROFINET can be operated via: ● Standard Ethernet interfaces (RT) Additional information You can find additional information on the Internet at: Technical Support (https://support.industry.siemens.com/cs/ww/en/). SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 54: Connecting Ethernet/Usb Strain Relief

    2. Connect the network and USB cables with the device and secure the connectors to the ② strain relief with cable ties 3. Secure the connectors of the COM and DVI connection by screwing the connectors. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 55: Commissioning The Device

    You can find information on this in the detailed firmware/BIOS description, see Important instructions and manuals for operating the device (Page 11). The exact minimum required downtime of the mains voltage is dependent on the device equipment and the application. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 56: Switching Off The Device

    ● Shut down the operating system and unplug the power plug from the rear of the device, see "Front panel (Page 16)". The device is switched off and fully disconnected from the line voltage. No trickle current is flowing. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 57 • Data on the hard disk drive may be lost. • The device may be damaged. Perform a hardware reset only in the case of an emergency. See also General safety instructions (Page 27) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 58 Commissioning the device 4.3 Switching off the device SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 59: Operating The Device

    If you have ordered a RAID1 system with pre-installed operating system, the RAID1 system is monitored with the installed diagnostics software SIMATIC IPC DiagBase or DiagMonitor. The following software is available to monitor the RAID1 system: ● Onboard RAID system: Intel® Rapid Storage Technology SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 60: Operating Raid Systems

    "Intel® Rapid Storage Technology" (Page 62)". 5.3.2 RAID1 system: Installation options for drives The two hard drives required for a RAID1 system can be installed in SIMATIC IPC627E in the following locations: ● For onboard RAID system: – "Drives (Page 79)"...
  • Page 61 If when exiting the firmware/BIOS menu with the <Esc> button, the warning message "Exit Discarding Changes" is displayed, confirm this message with "Yes". The prenumbered settings are saved nonetheless and you can leave the firmware/BIOS menu. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 62: Monitoring The Onboard Raid System With "Intel® Rapid Storage Technology

    – a defective drive – a functioning drive Example display status of a RAID1 system: Creating a report on the onboard RAID system 1. Select the "Help" tab. 2. Select "System Report" > "Save". SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 63: Integrating A New Drive Into The Onboard Raid System

    Manually integrating a replaced drive (after a fault) You can manually install a replaced drive in the onboard RAID system as follows: ● In the running system (without restarting the device). ● After switching off the unit SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 64: Data Synchronization In The Raid System

    Guide value for the duration of data synchronization: ● < 3h at 90% HDD system load In addition, system performance may be limited in the case of a manually started maintenance operation until completion of the maintenance phase. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 65: Monitoring Of The Device

    You can find information on the monitoring software and its documentation under: ● SIMATIC IPC DiagBase (Page 66) for monitoring and alarming locally on the device ● SIMATIC IPC DiagMonitor (Page 66) for monitoring and alarming via network SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 66: Simatic Ipc Diagbase

    Note SIMATIC IPC DiagMonitor version 5.1.0 and higher SIMATIC IPC DiagMonitor only supports the device hardware as of version 5.1.0. Older versions do not support the device hardware. See also Accessories: Software (Page 25) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 67: Remote Maintenance Of The Device

    (Page 11)". Software for remote maintenance of the device You can find information about the software for remote maintenance of the device and its documentation under: ● SIMATIC IPC Remote Manager (Page 68) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 68: Simatic Ipc Remote Manager

    You can find information on the software and documentation of SIMATIC IPC Remote Manager under: ● SIMATIC IPC Remote Manager (http://support.automation.siemens.com/WW/view/en/48707158) ● Important instructions and manuals for operating the device (Page 11) See also SIMATIC IPC software (http://www.automation.siemens.com/mcms/pc-based- automation/en/industrial-pc/expansion_components_accessories) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 69: Trusted Platform Module (Tpm)

    A USB keyboard and mouse and an analog CRT monitor can be later connected for diagnostics. A digital DVI monitor or DisplayPort monitor is only activated retrospectively when the Windows operating system has booted completed. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 70 Operating the device 5.8 Operation without monitor and keyboard SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 71: Expanding And Assigning Parameters To The Device

    Electrostatic-sensitive components The device contains electronic components which may be destroyed by electrostatic charge. This can result in malfunctions and damage to the machine or plant. Take corresponding precautionary measures before you open the device. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 72 6.1 Opening the Device Requirement ● All connecting cables are unplugged ● Screwdriver of type Torx T10 Procedure 1. Remove the four marked screws in the cover. 2. Remove the cover by lifting it SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 73: Expansion Cards

    You can find the permitted dimensions for expansion cards under "Dimension drawing of the expansion cards (Page 129)". See also Expansion card slots on the bus board (Page 139) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 74: Installing/Removing Expansion Cards

    • Do not apply excessive force on the slider when you push it onto the expansion card. ① 1. Remove the marked screw and swivel the cover to the side as shown. Then remove the marked screws and the panels. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 75 The slots for the expansion cards come with exclusive interrupts. The assignment of the PCI IRQ line to the PCI slot is explained in the chapter "Bus board (Page 139)". Procedure - Removal Proceed in reverse order of installation. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 76: Memory Modules

    ● In faults occur, it may be enough to remove one or two memory modules or use a memory module with less capacity so that the physical memory set up on the motherboard and the reserved memory on the expansion card do not overlap. See also Opening the Device (Page 71) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 77: Installing And Removing Memory Module

    2. Open the two locking mechanisms ② ③ on the left and right of the slot. 3. Insert the module downwards, ap- plying slight pressure and press it until the locking snaps into place. 4. Close the device. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 78 A new memory module is automatically detected. When switching on the device and starting the BIOS Setup using <F2>, the current memory size is displayed under "Total Memory". See also General safety instructions (Page 27) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 79: Drives

    1. Open the lock of the removable tray with the appropriate key. 2. Fold out the removable tray bracket somewhat to the front and pull out the removable tray by the tray bracket in the direction of the arrow. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 80 Ensure that the removable tray fits tightly in the drive cage. 7. Close the tray bracket. 8. Lock the removable tray with the key. Note The removable tray must always be locked to ensure reliable operation of the devices with removable trays. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 81: Changing Internal Ssd

    ● An original spare part, that is an SSD of the same type, see information under Accessories: Hardware (Page 24). Procedure - Removal 1. Remove the marked screws. 2. Remove the marked screws and place the SSD on its side. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 82 Expanding and assigning parameters to the device 6.4 Drives 3. Remove the marked connectors. 4. Remove the marked screws. 5. Remove the carrier with the connectors, remove the marked screws and take out the SSD. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 83 Expanding and assigning parameters to the device 6.4 Drives Procedure - Installation Proceed in reverse order. When connecting multiple drives, observe the assignments of the port connections (see PCB labeling). SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 84: Changing Internal Hard Disk Drive

    ● An original spare part, that is a hard disk drive of the same type, see information under Accessories: Hardware (Page 24). Procedure - Removal 1. Remove the marked screws and place the hard disk drive on its side. 2. Remove the marked screws and the drive carrier. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 85 Expanding and assigning parameters to the device 6.4 Drives 3. Remove the marked connectors and remove the hard disk. Procedure - Installation Proceed in reverse order. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 86: Replacing A Drive In The Raid System

    Therefore, place the RAID system in the first place of the bootable sources in the BIOS setup menu "Boot > EFI". Otherwise, the system is booted from the drive you have just installed and the message "Operating system not found" is displayed. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 87: Replacing M.2 Nvme Ssd

    3. Lift the M.2 NVMe SSD slightly as shown and pull it out of the direct connector socket. 4. Lay the thermal pad on the bus board in such a manner that it is covered completely by the M.2 NVMe SSD after the SSD's installation. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 88 5. Insert the M.2 NVMe SSD slightly inclined from above into the provided direct connector socket. 6. Carefully push the M.2 NVMe SSD down and secure it with the screw. 7. Install the bus board and then the drive bay module and the power supply again. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 89: Device Maintenance And Repair

    • For this reason, please observe the information in "Notes on device and system extensions (Page 34)". See also Spare parts service (https://support.industry.siemens.com/cs/ww/en/sc/2110) Maintenance intervals To maintain high system availability, we recommend the preventative replacement of those PC components that are subject to wear. The table below indicates the intervals for this replacement.
  • Page 90: Removing And Installing Hardware

    ● An original spare part, that is a fan of the same type, see information under Accessories: Hardware (Page 24). Procedure - Removal ① 1. Remove the two screws and remove the air guide pulling it up vertically. 2. Loosen the plastic rivets. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 91 Device maintenance and repair 7.3 Removing and installing hardware ② 3. Remove the four plastic rivets on the enclosure. 4. Take the fan out of the enclosure. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 92 • Direction of flow: Make sure that the blades/bars of the fan housing are on the outside of the enclosure. • Run the power supply cable along the enclosure edge and fasten the cable. The marked symbols show the rotation and flow direction of the fan. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 93: Replace Power Supply Fan

    ● An original spare part, that is a fan of the same type, see information under Accessories: Hardware (Page 24). Procedure - Removal ① 1. Remove the four plastic rivets on the enclosure and remove the marked screw 2. Pull the power supply connector and remove the marked screws. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 94 Device maintenance and repair 7.3 Removing and installing hardware 3. Take the power supply out of the enclosure. 4. Remove the power supply fan and pull the fan plug. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 95 • Direction of flow: Make sure that the blades/bars of the fan housing are on the outside of the enclosure. • Run the power supply cable along the enclosure edge and fasten the cable. The marked symbols show the rotation and flow direction of the fan. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 96: Changing The Backup Battery

    • Replace spent batteries promptly. See information in "Maintenance intervals (Page 89)". • Replace the lithium battery only with an identical battery or types recommended/approved by SIEMENS. • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100 °C and...
  • Page 97 7.3 Removing and installing hardware Procedure 1. Remove the marked screw. 2. Remove the battery holder. 3. Replace the battery, reinsert the battery holder and fasten it with the screw. See also Accessories: Hardware (Page 24) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 98: Replace Power Supply

    ● An original spare part, i.e. a power supply of the same type, see notes under Accessories: Hardware (Page 24). Procedure - Removal ① 1. Remove the marked screw 2. Pull the power supply connector and remove the marked screws. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 99 Device maintenance and repair 7.3 Removing and installing hardware 3. Take the power supply out of the enclosure. Procedure - Installation Note Install only a power supply of the same type. Proceed in reverse order. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 100: Replacing The Bus Board

    1. Remove all modules from the slots. 2. Remove the marked screws on the bus board. 3. Remove the marked screws. 4. Remove the back-up battery holder, see Changing the backup battery (Page 96). SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 101 Device maintenance and repair 7.3 Removing and installing hardware 5. Remove the marked screws and remove the top drive bay module (including hard disk). SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 102 Device maintenance and repair 7.3 Removing and installing hardware 6. Remove the marked hexagonal pins and remove the bottom drive bay module (including hard disk). SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 103 7. Remove the power supply, see also Replace power supply (Page 98). 8. Pull the bus board from the motherboard as shown in the figure. Procedure - Installation Note Install only a bus board of the same type. Proceed in reverse order. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 104: Replacing The Processor

    If the installed processor is operated with a higher clock frequency than permitted, it can be destroyed or cause loss of data. • Operate the processor only at a clock frequency that is equal to or less than the permitted clock frequency. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 105 4. Install the new processor on the socket, as shown in the figure. During positioning, make sure to take the highlighted arrow on the processor into consideration. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 106 The processor is not correctly locked in place by the bay. The result may be malfunctions. • Do not use excessive force. • Tilt the lever back again and try again. See also Contacts (http://www.siemens.com/automation/partner) SIMATIC IPC after-sales information system (http://www.siemens.com/asis) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 107: Installing Operating System, Software And Drivers

    Windows®, which supports the hardware of the device as of version 3.5.3. You will find detailed information on this software in: "SIMATIC IPC Image & Partition Creator (https://support.industry.siemens.com/cs/ww/de/view/21766418/en)". Please also observe the information in "Technical specifications of the operating systems (Page 119)". SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 108: Recycling And Disposal

    Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old device, and dispose of it according to the relevant regulations in your country. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 109: Technical Specifications

    Max. power consumption AC and Active power 176 W Noise emission < 55 dB(A) according to EN ISO 7779 Degree of protection IP 20 to IEC 60529 Quality assurance In accordance with ISO 9001 SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 110 The device must only be connected to a 24 V DC power supply which meets the require- ments of safe extra-low voltage (SELV) according to IEC/EN/DIN EN/UL 601010-2-201. A protective conductor must also be used (see chapter "Connecting the 24 VDC power supply (Page 49)"). SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 111: Current/Power Requirements And Power Supply

    The total power for individual PCI/PCIe slots cannot exceed 25 W. The total power for USB and PCI/PCIe slots cannot exceed 50 W. The total power of the + 5 V and + 3.3 V voltage must not exceed 60 W. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 112 0.04 A 0.33 A 1 × 2.5" SATA HDD 0.02 A 0.13 A USB ports Max. 0.06 A Max. 0.54 A Max. 13 W PCI/PCIe slots Max. 0.26 A Max. 2.54 A Max. 59 W SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 113: Technical Specifications Ac Power Supply (Ac)

    Max. 1.7 A Starting current (load-independent) Up to 50 A for 1 ms Active power 176 W Apparent power 190 VA Output data Voltages +12 V / 12.5 A Secondary power output Max. 150 W SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 114: Technical Specifications Dc Power Supply (Dc)

    Continuous current Max. 8 A Starting current (load- up to 13 A for 50 ms independent) Active power 176 W Output data Voltages +12 V / 12.5 A Secondary power output Max. 150 W SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 115: Electromagnetic Compatibility

    3 V/m 2.7 – 6 GHz, • 80% AM to IEC 61000-4-3 10 V 10 KHz–80 MHz, • 80% AM to IEC 61000-4-6 Immunity to magnetic fields 100 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 116: Ambient Conditions

    See the note in "Applicability of technical specifications (Page 109)". 2.5" SATA HDD, ≥ 320 GB 2.5" SATA SSD, ≥ 480 GB standard M.2 NVMe SSD 480 GB, form factor 22 mm x 80 mm, Type M SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 117: Technical Specifications Of The Motherboard

    PCI: Specification Rev. 2.3, length: max. 240 mm Slot 3 PCI: Specification Rev. 2.3, length: max. 185 mm Slot 4 PCIexpress x4: Specification Rev. 3.0, length: max. 185 mm Slot 5 PCIexpress x16: Specification Rev. 3.0, length: max. 185 mm SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 118: Technical Specifications Of Graphic

    For unique labeling, the Ethernet ports are numbered on the enclosure. The numbering by the operating system can differ. No teaming with AMT. When using AMT, the interface X1P1 must be used for connection to remote maintenance. An analog monitor can be used with an adapter cable (optional). SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 119: Technical Specifications Of The Operating Systems

    The following table lists the partitioning for disks ≥ 200 GB in GPT mode: Partition Name Size File system First Boot 260 MB FAT32 Second 128 MB None Third System 160 GB NTFS (compressed) Fourth WinRE 500 MB NTFS (compressed) Fifth Data Remainder NTFS (compressed) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 120 Technical specifications 8.10 Technical specifications of the operating systems SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 121: Dimension Drawings

    Dimension drawings Dimension drawings of SIMATIC IPC627E (2 expansion slots) Dimension drawing for mounting without wall mounting rails All dimensions in mm SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 122 Dimension drawings 9.1 Dimension drawings of SIMATIC IPC627E (2 expansion slots) Dimension drawing for mounting with wall mounting rails All dimensions in mm SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 123 Dimension drawings 9.1 Dimension drawings of SIMATIC IPC627E (2 expansion slots) Dimension drawing for mounting with vertical mounting kit All dimensions in mm SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 124 Dimension drawings 9.1 Dimension drawings of SIMATIC IPC627E (2 expansion slots) Dimension drawing for installation with the vertical mounting kit for PC port access from the front All dimensions in mm SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 125: Dimension Drawings Of Simatic Ipc627E (5 Expansion Slots)

    Dimension drawings 9.2 Dimension drawings of SIMATIC IPC627E (5 expansion slots) Dimension drawings of SIMATIC IPC627E (5 expansion slots) Dimension drawing for mounting without wall mounting rails All dimensions in mm SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 126 Dimension drawings 9.2 Dimension drawings of SIMATIC IPC627E (5 expansion slots) Dimension drawing for mounting with wall mounting rails All dimensions in mm SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 127 Dimension drawings 9.2 Dimension drawings of SIMATIC IPC627E (5 expansion slots) Dimension drawing for mounting with vertical mounting kit All dimensions in mm SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 128 Dimension drawings 9.2 Dimension drawings of SIMATIC IPC627E (5 expansion slots) Dimension drawing for installation with the vertical mounting kit for PC port access from the front All dimensions in mm SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 129: Dimension Drawing Of The Expansion Cards

    Dimension drawings 9.3 Dimension drawing of the expansion cards Dimension drawing of the expansion cards Short PCI or PCIe expansion card Long PCI or PCIe expansion card SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 130 Dimension drawings 9.3 Dimension drawing of the expansion cards SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 131: Standards And Approvals

    ● 2011/65/EU "Restriction of the use of certain hazardous substances in electrical and electronic equipment" (RoHS Directive) EU Declaration of Conformity The associated declaration of conformity is available on the Internet at the following address: Certificate Box PC (http://support.automation.siemens.com/WW/view/en/10805671/134200). SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 132: Din Iso 9001 Certificate And Software License Agreements

    DIN ISO 9001 certificate and software license agreements ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 133: Fcc (Usa)

    (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Responsible party for Supplier's Declaration of Conformity Siemens Industry, Inc. Digital Factory - Factory Automation 5300 Triangle Parkway, Suite 100 Norcross, GA 30092 mailto: amps.automation@siemens.com...
  • Page 134: Canada

    This product meets the requirements of Korean certification. This product satisfies the requirement of the Korean Certification (KC Mark). 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 135: Hardware Description

    Flash BIOS. ① Slots for memory modules ② Processor ③ Slots for bus boards Technical features of the motherboard Technical features of the motherboard can be found under "Technical specifications of the motherboard (Page 117)". SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 136: Position Of The Interfaces On The Motherboard

    PS fan (X52) (26) RAM DIMM2-2 (X200) LAN 3 (X3 P1) (17) 4x SATA-SV (X516-X519) (27) RAM DIMM2-1 (X20) USB 3.1 (X60-X65) (18) SATA 3 (Port5) (X522), 4x type A, 2x type C IPC627E-5 only SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 137: Internal Interfaces

    • Replug to pins 1-2 for ME Update • A special USB stick is required for this (not included in scope of delivery; contact your local SIEMENS representative) Serial ATA Internal Serial ATA, max. 2 /4 drives operable Connection for PS...
  • Page 138: Supply For The Power Supply Fan (X515)

    PG1 FAN_CLK Clock signal PWM signal A.2.4 Supply for the serial ATA drives (X516 - X521) Name Meaning +12 V Output power supply Ground Ground +5 V Output power supply +3.3 V Output power supply SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 139: Bus Board

    Version 2 (IPC627E; 2 slots) ① Slot 1 PCI ② Slot 2 PCI Express x16 ③ 12 V power supply connection; see Pin assignment 12 V power supply connection for expan- sion cards (Page 141) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 140 ② Slot 4 PCI Express x4 (mechanical x16) ③ Slot 5 PCI Express x16 ④ 12 V power supply connection; see Pin assignment 12 V power supply connection for expan- sion cards (Page 141) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 141: Pin Assignment 12 V Power Supply Connection For Expansion Cards

    12 V voltage Output Ground Ground +5 V 5 V voltage Output max. permitted current: 1 A; with this power demand the total power demand for the PCI slots are not allowed to be exceeded. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 142: External Interfaces

    (5 V; 1.5 A to 3.0 A; up to 10 Gbps) Ethernet 1, 2 and X1P1, RJ45 X2P1, (up to 1 Gbps) X3P1 DVI-D 24-pin DVI-D female connector (5 V; 500 mA) X71, X72 20-pin DisplayPort connector (3.3 V; 500 mA) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 143: System Resources

    0036 0037 <Not used> 0038 0039 Programmable interrupt controller 003A 003B <Not used> 003C 003D Programmable interrupt controller 003E 003F <Not used> 0040 0043 System timer 0044 004D <Not used> 004E 004F Motherboard resources SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 144 Programmable interrupt controller 00BE 00BF <Not used> 00C0 00DF DMA controller 00E0 00EF <Not used> 00F0 00F0 Numeric data processor 00F1 0277 <Not used> 0278 027F <Reserved> Reserved for LPT1 0280 02E7 <Not used> SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 145 04D0 04D1 Programmable interrupt controller 0680 069F Motherboard resources 0800 087F Motherboard resources 164E 164F Motherboard resources 1800 18FE Motherboard resources 1854 1857 Motherboard resources Cascaded 2004 2007 Motherboard resources FFFF FFFF Motherboard resources SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 146: Interrupt Assignments

    Host PCI-IRQ A to H is assigned to IRQ 16 to 23 permanently in APIC mode. Host PCI-IRQ A to H will be automatically assigned IRQ 0 to 15 by BIOS in PIC mode. A specific assignment can not be enforced. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 147 Host PCI-IRQ A to H will be assigned IRQ 16 to 23 permanently in ACPI mode. Host PCI-IRQ A to H will be automati- cally assigned IRQ 0 to 15 in PIC mode. A specific assignment can not be enforced. Interrupt in APIC mode BIOS Default Interrupt in PIC mode (e.g. DOS) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 148: Exclusive Pci Hardware Interrupt

    Exclusive interrupts are not available in PIC mode. Disable specific system resources in order to obtain exclusive interrupts. BIOS assigns the PIC interrupts at random during restart of the system. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 149: Memory Address Assignments

    FED4 4FFF 20 K Trusted Platform Module 2.0 FED9 0000 FED9 3FFF 16 K Motherboard resources FEE0 0000 FEEF FFFF Motherboard resources FF00 0000 FFFF FFFF 16 M Motherboard resources Intel 82802 firmware ® SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 150 Hardware description A.5 System resources SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 151: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com/cs/ww/en/) ● Support request form (http://www.siemens.com/automation/support-request) ● After-sales information system for SIMATIC PC / PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa- db/en/Pages/default.aspx)
  • Page 152: Troubleshooting

    If you use an adapter or expansion for the mouse • cable, also check these connectors. If the cursor still does not appear on the screen after you have performed these checks and actions, con- tact your technical support team. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 153: Problems When Booting The Device

    "Boot > Boot device". (BIOS) The boot data storage medium is Activate UEFI mode in the firmware (BIOS). set up with GPT, and UEFI boot is deactivated in the firmware (BIOS) SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 154: Problems With Raid Systems

    Signal frequencies or signal • pansion card was the cause of the fault. Replace this with a levels are not adhered to Siemens expansion card or contact the supplier of the ex- Different pin assignment • pansion card. If the device still crashes, contact your technical support team.
  • Page 155: Markings And Symbols

    Disconnect the power plug before Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- On/off switch, without electrical isola- tion tion SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 156: Certificates, Approvals And Markings

    Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters La- Disposal information, observe the boratories local regulations. Approval for India SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 157: Interfaces

    LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port USB 3.1 SuperSpeedPlus interface SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 158 Markings and symbols C.5 Interfaces SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 159: List Of Abbreviations

    Digital Visual Interface Digital display interface with digital and VGA signals Error checking and correction Error correction code Extensible Firmware Interface Electrostatic-sensitive components European standard Ground Chassis ground Hard Disk Drive Hard disk drive Height unit SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 160 US organization for tests and certifications ac- cording to own or binational standards (with CSA / Canada) standards. Universal Serial Bus Video Graphics Array Video adapter which meets industrial standard Watchdog Program monitoring with error detection and alarming. SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 161: Index

    Device fan supply, 137 Memory modules, 76 Dimension drawings Installing Device, 121 Memory modules, 77 Dimensional drawings Modules, 74 Expansion card, 129 Interfaces, 17, 19, 118 Dimensions, 109 Ethernet RJ 45, 53 PROFINET, 53 SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 162 SIMATIC IPC Image & Partition Creator, (Image & Partition Creator) SIMATIC IPC Remote Manager, 68 Package contents, 37 SIMATIC S7, 53 Checking, 37 Slot cover, 75 Packaging, 37 SOFTNET S7, 53 Checking, 37 Startup, 69 Removing, 37 PCI hardware interrupt, 148 SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 163 Switching on the device Configure automatic startup, 55 System resources, 143 I/O address allocation, 143 Temperature, 116 Vertical mounting, 43 Front interfaces, 44 Wall mounting, 42 Weight, 109 WinAC module Power supply connection, 141 SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...
  • Page 164 Index SIMATIC IPC627E Operating Instructions, 12/2018, A5E44297201-AA...

Table of Contents