Siemens SIMATIC IPC647C Getting Started
Hide thumbs Also See for SIMATIC IPC647C:

Advertisement

Quick Links

SIMATIC IPC647C

SIMATIC
Industrial PC
SIMATIC IPC647C
Getting Started
12/2010
A5E02669344-02

___________________
Introduction
___________________
Description
___________________
Application planning
___________________
Installing
___________________
Connecting
___________________
Commissioning
___________________
Troubleshooting
___________________
Dimension drawings
___________________
Appendix
1
2
3
4
5
6
7
8
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC647C

  • Page 1 ___________________ SIMATIC IPC647C Introduction ___________________ Description ___________________ Application planning SIMATIC ___________________ Installing Industrial PC ___________________ SIMATIC IPC647C Connecting ___________________ Commissioning Getting Started ___________________ Troubleshooting ___________________ Dimension drawings ___________________ Appendix 12/2010 A5E02669344-02...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Requirements for commissioning....................27 Initial Commissioning - Initial Startup...................28 Reinstalling the software......................29 Troubleshooting ............................31 General problems ........................31 Dimension drawings ..........................35 Dimensional drawing of the device ....................35 Dimensional drawing for the use of telescopic rails..............36 SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 4 Table of contents Appendix..............................37 Guidelines and Declarations ....................... 37 Certificates and Approvals ......................38 Service and support ........................39 Index................................ 41 SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 5: Introduction

    The operating instructions provide useful information on many topics such as the hardware expansion options, modification of the system configuration and technical data. Conventions The term "rack PC" or "device" is sometimes used to refer to the SIMATIC IPC647C product in this documentation. The abbreviation "CP" stands for CP 1616 onboard.
  • Page 6 Introduction SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 7: Description

    Rear view of the device (example) ① DP connection of graphics card ② Connection elements ③ Expansion slots ④ Equipotential bonding connection ⑤ Power supply connector ⑥ Fan / power supply unit SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 8: Operator Controls

    Data may be lost when the PC performs a hardware reset. WARNING The on/off button signal does not cut off power to the PC! To disconnect the device completely from the power supply, pull out the power connector. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 9: Connecting Elements

    Description 2.3 Connecting elements Connecting elements Layout of the interfaces on the rear of the device SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 10 Display port connection of the DP adapter at Dual Head graphics card (optional) ⑮ Connecting potentials Connection for equipotential bonding LAN interfaces are numbered on the enclosure to provide unique identification. The numbering by the operating system may deviate from this. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 11: Status Displays

    100 to 240 V AC is permissible as the input voltage. Status displays Front status displays Display Meaning Description POWER PC status display isolated from mains YELLOW Standby (hibernating) GREEN PC in operation Display for hard disk no access access GREEN Access SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 12 Error in early BIOS Post All lit CPU startup failure Error in early POST LAN interfaces are numbered on the enclosure to provide unique identification. The numbering by the operating system may deviate from this. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 13 The two "virtual" CP 1616 LEDs are only visible in the SIMATIC software and can be read via SNMP. PROFINET Virtual LEDs CP is active STOP CP is in the stop state Flashes The states "flashes slowly" or "flashes rapidly" do not exist. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 14 Description 2.4 Status displays SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 15: Application Planning

    ● Verify that the shipment contains the complete unit and your separately ordered accessories. Please inform your local dealer of any disagreements or transport damage. ● Please inform Siemens AG by means of the enclosed SIMATIC IPC/PG quality control report form.
  • Page 16 Order no. 6AG4112-1 ... Microsoft Windows Product Key Ethernet 1 address Ethernet 2 address CP 1616 onboard layer 2 Device equipment The device equipment is listed on the inner side of the front door. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 17: Ambient And Environmental Conditions

    ● The connected or built-in peripherals should not introduce a counter emf in excess of 0.5 V into the device. Access protection The access protection of the rack PC is only enabled if the front door is locked. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 18 Application planning 3.4 Access protection SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 19: Installing

    The proper use of the device has to be verified with a function test on the system. This test can detect programming, configuration and wiring errors. The test results have to be documented and if necessary inserted into the relevant inputs. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 20: Technical Data Of The Telescopic Rails

    It is not permitted to install the device only on the 19-inch brackets of the front panel. Technical data of the telescopic rails Ultimate load per pair At least 14 kg Full extraction length At least 470 mm Rail thickness Maximum 9.7 mm Mounting screws M5 x 6 mm SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 21: Connecting

     The computer in question must be turned off and the power supply connector should be plugged in.  During the measurement, all cables from the plant to the computer should be connected.  All other components in the plant must be active. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 22: Connecting The Device To Power

    SIMATIC PCs with a PFC circuit. UPS characteristics are described and classified in the standards EN 50091-3 and IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 23 4.5 m, and tandem grounded connector 15 A, min. 250 V. Label on the device The back of the device has a warning label in English, Norwegian, Finnish and Chinese informing the user that the device must be connected to properly grounded electrical outlets. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 24 (1). WARNING If the power plug is secured with a clamp, the power outlet must be freely accessible to allow the device to be easily removed from the mains. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 25: Equipotential Bonding

    One cable tie (not included in the package) is required for each interface. To fix the strain relief, you will need a TORX T10 screwdriver. To fix the PROFINET strain relief, you will need a TORX T10 screwdriver. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 26 2. Install the plate for the Profinet and Ethernet connectors. Use the retaining screw of the PROFINET interface plate for this purpose. 3. Install the Profinet and Ethernet connectors at the respective positions and fasten the cables with cable ties. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 27: Commissioning

    ● Before you switch on the device, you should verify that all peripheral devices such the keyboard, mouse, monitor and the power supply are connected. ● The operating system of your device is preinstalled on the hard disk. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 28: Initial Commissioning - Initial Startup

    Press the on/off button behind the front panel door. The green power LED is switched off. WARNING Completely separating the device from the power supply For complete separation of the device from the power supply pull the power connector. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 29: Reinstalling The Software

    All existing data, programs, user settings and authorizations or license keys will be deleted from the hard disk and are therefore lost. For information on the functions, refer to the README.TXT file on the Restore DVD. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 30 Commissioning 6.3 Reinstalling the software SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 31: Troubleshooting

    USB device not The USB ports are disabled in Use a different USB port or enable the port. responding. BIOS. USB 2.0 device connected and Enable USB 2.0. USB 2.0 is disabled. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 32 Use a KVM switch that passes through DDC information  KVM switch does not pass  Use a basic cable adapter with DVI-I to VGA connector.  through DDC information. Y cable adapter with DVI-I  for DVI-D/VGA connector is being used SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 33 Red SF PROFINET LED is lit A fault has occurred on the CPU Section "CP 1616 onboard communications 1616 onboard interface processor" All front-panel LEDs are Error in early BIOS-POS In this case, contact Technical Support. constantly lit SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 34 Troubleshooting 7.1 General problems SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 35: Dimension Drawings

    Dimension drawings Dimensional drawing of the device Figure 8-1 Dimensions IPC647C SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 36: Dimensional Drawing For The Use Of Telescopic Rails

    Below you will find the dimensions of the telescopic rails from the Rittal company: ● Type RP 3659.180 for 600 mm cabinet ● Type RP 3659.190 for 800 mm cabinet 34,83 1.37 3.97 3.97 3.97 Figure 8-2 Dimensional drawing for the use of telescopic rails SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 37: Appendix

    EC directives stated above. Your sales representative can provide these on request. Observe the installation guidelines The installation guidelines and safety instructions specified in this documentation must be observed for commissioning and operation. SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 38: Certificates And Approvals

    Peripheral devices may only be connected via shielded cables. Certificates and Approvals ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets ISO 9001:2000 requirements. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 39: Service And Support

    Generic standards - Emission standard for residential, commercial and light-industrial environments. Service and support Local information Contain your Siemens representative (http://www.siemens.com/automation/partner) if you have questions about the products described here. Technical documentation for SIMATIC products You can find additional documentation for SIMATIC products and systems in the Internet: SIMATIC Guide manuals (http://www.siemens.com/simatic-tech-doku-portal)
  • Page 40 Industry Automation and Drive Technologies - Homepage (http://www.siemens.com/automation/service&support) After-sales information system for SIMATIC PC / PG Information about contacts, drivers, and BIOS updates, FAQs and Customer Support can be found at: After-sales information system for SIMATIC PC/PG (http://www.siemens.com/asis) SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 41: Index

    Power supply, 22 Front view, 7 Connecting, 22 Power supply unit, 7 PROFINET strain relief, 25 Protection class, 17 I/O devices, 21 Identification data, 16 IEC connector, 11, 24 Initial commissioning, 28 Rating plate, 16 SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...
  • Page 42 POWER, 11 PROFIBUS/MPI, 12 TEMP, 12 WATCHDOG, 12 Strain relief Network cable, 25 Supply voltage, 23 Telescopic rails Installation, 20 Specifications, 20 TEMP, 12 Transport, 15 USB interface, 7 Ventilation slots, 17 Watchdog, 12 SIMATIC IPC647C Getting Started, 12/2010, A5E02669344-02...

Table of Contents