hit counter script

Advertisement

PRIMEQUEST 3800E2
System Configuration Guide
July. 2019 Ver. 2.0
Contents
0
1
6. MMB
2
7. I/O Unit
5
7
9. HDD / SSD / PCIe-SSD
8
10. Power Supply Unit (PSU), Power Cords
9
10
11
12

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu PRIMEQUEST 3800E2

  • Page 1: Table Of Contents

    PRIMEQUEST 3800E2 System Configuration Guide July. 2019 Ver. 2.0 Contents 1. Overview 2. Base unit 3. System Board (SB) 4. CPU 5. Memory 6. MMB 7. I/O Unit 8. Disk Unit (DU) 9. HDD / SSD / PCIe-SSD 10. Power Supply Unit (PSU), Power Cords 11.
  • Page 2: Overview

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 1.Overview July 2019, Ver.2.0 Front side Disk Unit for Disk/MMB Unit (Disk Unit_M) System Board Disk Unit for SAS Rear side Management Board Power Supply Unit I/O Unit 2 of 42...
  • Page 3 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide Configuration Diagram July 2019, Ver.2.0 PSU_M#0 PSU_M#1 MMB#0 MMB#1 Disk Unit_M #0 Disk Unit_M #1 Disk Unit _M#2 Disk Unit_M #3 RAID RAID RAID RAID HDD/SSD HDD/SSD HDD/SSD HDD/SSD Card Card Card Card...
  • Page 4: Base Unit

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 2.Base Unit July 2019, Ver.2.0 Part Numbers Legend: Part numbers: PSU#0 PSU#1 PSU#2 PSU#3 MX-****** is a Build-to-Order (BTO) option to be assembled with Base Unit SB #0 MCX****** is an option to be shipped separately from Base Unit (Loose Delivery)
  • Page 5: System Board (Sb)

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 3.System Board (SB) July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 SB #0 SB #1 SB #2 SB #3 Memory Memory x12 slots x12 slots 1x System Board is included in the Base Unit.
  • Page 6 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide USB Flash Device & M.2 Flash Device July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 SB #0 SB #1 SB #2 SB #3 Memory Memory x12 slots x12 slots Only one type of the following options can be installed on each System Board.
  • Page 7: Cpu

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 4.CPU July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 - 2x CPUs required for one System board except PPAR with 1SB. - Combinatios of PPAR is only "SB#0 and SB#1" or "SB#2 and SB#3"...
  • Page 8 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 4.CPU July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 - 2x CPUs required for one System board except PPAR with 1SB. - Combinatios of PPAR is only "SB#0 and SB#1" or "SB#2 and SB#3"...
  • Page 9: Memory

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 5.Memory July 2019, Ver.2.0 PSU#0 PSU#3 PSU#1 PSU#2 SB #0 SB #1 SB #3 SB #2 Memory Memory x12 slots x12 slots - At least one set of memory (2 DIMMs) must be installed for each CPU.
  • Page 10 (2) Units of memory expansions : One set (2 DIMMs) for one CPU in Normal Mode and Spare Mode, 2 sets (4 DIMMs) for one CPU in Mirror Mode. 3. Memory Support for Operating Systems of PRIMEQUEST 3800E2 Max. Memory Capacity...
  • Page 11 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide Memory Mounting 2 July 2019, Ver.2.0 DIMM mounting order on System Board At least one AEP DIMMs have to be installed in one CPU. DDR4 DIMM installation order The order of DIMM installation is shown in the following table. DIMMs are installed in order from one with small number.
  • Page 12 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide Memory Mixed Condition July 2019, Ver.2.0 Which size of DIMM can be installed together in a DDR CH or an SB are shown in the following tables. The type of the DIMM mixed installation condition for each DIMM.
  • Page 13 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide Memory Mixed Installation Condition July 2019, Ver.2.0 DIMM mixed installation conditions are shown in the following table. Same symbols mean that same DIMMs can be installed which is defined in the table below.
  • Page 14 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide DCPMM(NVM/LRDIMM) installation pattern July 2019, Ver.2.0 At least one DCPMMs have to be installed in one CPU. Up to 6 DCPMMs can be installed in one CPU. DCPMM increment unit is one unit. If DCPMM is installed, DDR4 DIMM increment unit is one unit.
  • Page 15 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 6.Management Board (MMB) July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 SB #0 MSB #2 /MSB Memory Memory Memory Memory x12 slots x12 slots x12 slots x12 slots 1x MMB is included in the Base Unit.
  • Page 16 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 7.I/O UNIT July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 1x I/O Unit is included in the Base Unit. SB #0 SB #1 SB #2 SB #3 Max. 4x I/O Units can be mounted per Base Unit.
  • Page 17: Disk Unit (Du)

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 8.Disk Unit July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 SB #0 SB #1 SB #2 SB #3 Memory Memory x12 slots x12 slots Disk Unit - Max. 2 of the following Disk Units can be mounted on the Base Unit.
  • Page 18 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 8.Disk Unit July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 SB #0 SB #1 SB #2 SB #3 Memory Memory x12 slots x12 slots Disk Unit - Max. 2 of the following Disk Units can be mounted on the Base Unit.
  • Page 19 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide Disk Unit for DMBU(Disk/MMB Unit) (DU_M) July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 SB #0 SB #1 SB #2 SB #3 Disk Unit for DMBU(Disk/MMB Unit) (DU_M) Memory Memory x12 slots x12 slots - Max.
  • Page 20 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 9.HDD July 2019, Ver.2.0 Max. 4 pcs of HDD/SSD can be mounted per the Disk Unit or the Disk Unit for DMBU(Disk/MMB Unit) (DU_M). PSU#0 PSU#1 PSU#2 PSU#3 SB #0 SB #1 SB #2...
  • Page 21 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 9.SSD July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 Max. 4 pcs of HDD/SSD can be mounted per the Disk Unit or the Disk Unit for DMBU(Disk/MMB Unit) (DU_M). SB #0 SB #1 SB #3...
  • Page 22 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 9.PCIe-SSD July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 Max. 4 pcs of PCIe-SSD can be mounted per the Disk Unit for PCIe SFF. SB #0 SB #1 SB #3 SB #2 Memory Memory 1.6TB Solid State Drive...
  • Page 23 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 10.Power Supply Unit (PSU) July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 No PSU is included in the Base unit, At least two PSU's need to be mounted per system. SB #0 SB #1...
  • Page 24 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 10.Power Cords for APAC and Americas July 2019, Ver.2.0 PSU#0 PSU#1 PSU#2 PSU#3 SB #0 SB #1 SB #2 SB #3 power cord Memory Memory x12 slots x12 slots * The same quantity of Power Cords need to be ordered as that of PSU.
  • Page 25 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 10.Power Cords for EMEA & India July 2019, Ver.2.0 Base Unit Power Cords you need one cable for each PSU S26361-F3151-E301 T26139-Y3850-E10 Power Cord 16A No powercord as No mix of different power cords is possible.
  • Page 26: Pci Box

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 11.PCI Box July 2019, Ver.2.0 To connect a PCI Box, a PCI Box Connection Card needs to be ordered and mounted in an I/O Unit. Base Unit 1 x PCI Box cannot be connected to 2 different Base Units of PRIMEQUEST.
  • Page 27 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide Power Cords for PCI Box for APAC and Americas July 2019, Ver.2.0 Base Unit I/O Unit PCI slot 200V IEC AC Cable (1m) for PCI Box MC-0HCB41 - Plug: IEC60320 C14 (1m) LAN port...
  • Page 28: Pci Card

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide Power Cords for PCI Box for EMEA & India PCI Box Power Cords Power cord options (1x per PSU) T26139-Y1968-E100 Cable powercord rack, 4m, black Power cords have to be ordered separately. IEC 320 C14 -> C13 (10A plug)
  • Page 29 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 12.PCI Cards July 2019, Ver.2.0 Max. 56 PCI cards(excluding PCI Box Connection Cards) can be mounted in I/O Units and PCI Boxes. Base Unit I/O Unit : Max. 4 cards can be mouted per I/O Unit...
  • Page 30 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide PCI Cards 2 July 2019, Ver.2.0 Max. 56 PCI cards(excluding PCI Box Connection Cards) can be mounted in I/O Units and PCI Boxes. Base Unit I/O Unit : Max. 4 cards can be mouted per I/O Unit...
  • Page 31 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide PCI Cards 3 July 2019, Ver.2.0 Max. 56 PCI cards(excluding PCI Box Connection Cards) can be mounted in I/O Units and PCI Boxes. Base Unit I/O Unit : Max. 4 cards can be mouted per I/O Unit...
  • Page 32 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide PCI Cards 4 July 2019, Ver.2.0 Max. 56 PCI cards(excluding PCI Box Connection Cards) Base Unit can be mounted in I/O Units and PCI Boxes. I/O Unit : Max. 4 cards can be mouted per I/O Unit...
  • Page 33 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide PCI Cards 5 July 2019, Ver.2.0 Max. 56 PCI cards(excluding PCI Box Connection Cards) can be mounted in I/O Units and PCI Boxes. Base Unit I/O Unit : Max. 4 cards can be mouted per I/O Unit...
  • Page 34 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide PCI Cards 6 July 2019, Ver.2.0 Max. 56 PCI cards(excluding PCI Box Connection Cards) can be mounted in I/O Units and PCI Boxes. Base Unit I/O Unit : Max. 4 cards can be mouted per I/O Unit...
  • Page 35: Rack Installation

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide PCI Cards 7 July 2019, Ver.2.0 Max. 56 PCI cards(excluding PCI Box Connection Cards) can be mounted in I/O Units and PCI Boxes. Base Unit I/O Unit : Max. 4 cards can be mouted per I/O Unit...
  • Page 36 Rack Mount Kit: Rack for APAC & Americas - can be used to mount PRIMEQUEST to Rack Units which are delivered from Fujitsu factories (Japan and Germany). - is bundled with PRIMEQUEST Base Unit. Rack Units Model 2724 Base Rack...
  • Page 37 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 13.Rack Installation for EMEA and India July 2019, Ver.2.0 Rack Installation Rack mounting kit (RMK) is included in the PQ3000 Base Unit and PCI BOX. suitable for : - PRIMERGY 19" PRIMECENTER Rack, FJ rack, and 3rd party racks...
  • Page 38: Maximum Quantity Of Pcie Cards

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 14.Maximum Quantity of PCIe Cards July 2019, Ver.2.0 Maximum Quantity of PCI Cards that can be mounted. per Partition / per System Order Number Max. Qty Product Name BTO for PCI Box 3800E...
  • Page 39: Available Os

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 15. Available OS (1) July 2019, Ver.2.0 (1) Microsoft® Windows Server® 2016 (Standard/Datacenter) Order number (2) Microsoft® Windows Server® 2019 (Standard / Datacenter) (3) Red Hat® Enterprise Linux® 7.6 / 8.0 Product name (4) SUSE®...
  • Page 40 FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 15.Availalbe OS (2) July 2019, Ver.2.0 (1) Microsoft® Windows Server® 2016 (Standard/Datacenter) Order number (2) Microsoft® Windows Server® 2019 (Standard / Datacenter) (3) Red Hat® Enterprise Linux® 7.6 / 8.0 Product name (4) SUSE® Linux Enterprise Server 12 SP4 / 15...
  • Page 41: Restrictions

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide 16.Restrictions July 2019, Ver.2.0 The following functions are restricted as of July 2019. 1 Intel 10GbE LAN cards [MC*0JXEK*] (X710-DA2) can be mounted up to eight per PPAR. 2 "Intel TXT" does not work.
  • Page 42: Change Report

    FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide July 2019, Ver.2.0 Change Report Changes Date Order number July 2nd, 2019 Ver. 2.0 April 2nd, 2019 Ver. 1.0 42 of 42...

Table of Contents