SICAM
Multifunctional Recorder
SICAM Q200 7KG97
Communication
V02.00
Manual
E50417-C1040-C606-A3
Preface
Open Source Software
Table of Contents
User Information
Communication Modbus
Communication IEC 61850
Glossary
1
2
3

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SICAM Q200 7KG97

  • Page 1 Preface Open Source Software Table of Contents SICAM User Information Multifunctional Recorder Communication Modbus SICAM Q200 7KG97 Communication Communication IEC 61850 Glossary V02.00 Manual E50417-C1040-C606-A3...
  • Page 2 Although including rights created by patent grant or registration of a Siemens AG has made best efforts to keep the document as utility model or a design, are reserved. precise and up-to-date as possible, Siemens AG shall not...
  • Page 3: Preface

    This conformity has been proved by tests performed according to the Council Directive in accordance with the generic standard EN 61000-6-5 (for EMC directive) and with the product standard EN 62586-1 (for Low Voltage Directive) by Siemens AG The device is designed and manufactured for application in an industrial environment.
  • Page 4 Preface E-Mail: support.energy@siemens.com Training Courses Inquiries regarding individual training courses should be addressed to our Training Center: Siemens AG Siemens Power Academy TD Humboldtstraße 59 90459 Nürnberg Germany Phone: +49 (911) 433-7415 Fax: +49 (911) 433-7929 E-Mail: poweracademy@siemens.com Internet: www.siemens.com/poweracademy...
  • Page 5 The equipment (device, module) may be used only for such applications as set out in the catalogs and the technical description, and only in combination with third-party equipment recommended and approved by Siemens. Problem-free and safe operation of the product depends on the following: •...
  • Page 6 SICAM, Multifunctional Recorder, Manual E50417-C1040-C606-A3, Edition 03.2017...
  • Page 7: Open Source Software

    License Conditions provide for it you can order the source code of the Open Source Software from your Siemens sales contact - against payment of the shipping and handling charges - for a period of at least 3 years since purchase of the Product. We are liable for the Product including the Open Source Software contained in it pursuant to the license conditions applicable to the Product.
  • Page 8 SICAM, Multifunctional Recorder, Manual E50417-C1040-C606-A3, Edition 03.2017...
  • Page 9: Table Of Contents

    Table of Contents Preface................................3 Open Source Software..........................7 User Information............................11 General User Information....................12 Communication Modbus..........................13 Functions, Properties and Exception Responses for Modbus TCP Server and Modbus RTU (Slave)........................14 Functions and Properties for Modbus RTU Master.............. 16 Exception Responses from the Modbus Gateway...............
  • Page 10 SICAM, Multifunctional Recorder, Manual E50417-C1040-C606-A3, Edition 03.2017...
  • Page 11: User Information

    User Information General User Information SICAM, Multifunctional Recorder, Manual E50417-C1040-C606-A3, Edition 03.2017...
  • Page 12: General User Information

    User Information 1.1 General User Information General User Information This manual describes how SICAM Q200 communicates with peripheral devices/systems. For detailed device information, see the device manual. Communication The communication interfaces of SICAM Q200 make 4 communication types possible using the corresponding communication protocols: •...
  • Page 13: Communication Modbus

    Communication Modbus Functions, Properties and Exception Responses for Modbus TCP Server and Modbus RTU (Slave) Functions and Properties for Modbus RTU Master Exception Responses from the Modbus Gateway Modbus Registers Modbus Data Format SICAM, Multifunctional Recorder, Manual E50417-C1040-C606-A3, Edition 03.2017...
  • Page 14: Functions, Properties And Exception Responses For Modbus Tcp Server And Modbus Rtu (Slave)

    Communication Modbus 2.1 Functions, Properties and Exception Responses for Modbus TCP Server and Modbus RTU (Slave) Functions, Properties and Exception Responses for Modbus TCP Server and Modbus RTU (Slave) Modbus Functions for Modbus TCP Server and Modbus RTU (Slave) The Modbus TCP server and Modbus RTU (slave) of SICAM Q200 supports the following Modbus functions: Table 2-1 Supported Modbus TCP Server and Modbus RTU (slave) Functions Function...
  • Page 15 Communication Modbus 2.1 Functions, Properties and Exception Responses for Modbus TCP Server and Modbus RTU (Slave) • The Modbus RTU message has a maximum size of 256 bytes: – 1 byte server address – 253 bytes for data – 2 bytes for CRC Exception Responses for Modbus TCP Server and Modbus RTU (slave) The Modbus server performs a series of consistency checks of the Modbus client requests, and if errors (for example request to read a nonexistent register) are detected, it generates Modbus exception codes which are...
  • Page 16: Functions And Properties For Modbus Rtu Master

    Communication Modbus 2.2 Functions and Properties for Modbus RTU Master Functions and Properties for Modbus RTU Master Supported Modbus Register Sets • Coil status registers (0x references, read only) • Input status registers (1x references, read only) • Input registers (3x references, read only) •...
  • Page 17 Communication Modbus 2.2 Functions and Properties for Modbus RTU Master • The Modbus RTU message has a maximum size of 256 bytes: 1 byte server address 253 bytes for data 2 bytes for CRC NOTE The parameterization of the serial communication via the RS485 interface, the Modbus slave devices, and the associated mapping are described in detail in the SICAM Q200 device manual.
  • Page 18: Exception Responses From The Modbus Gateway

    Communication Modbus 2.3 Exception Responses from the Modbus Gateway Exception Responses from the Modbus Gateway If a request from the Modbus gateway cannot be forwarded to the associated Modbus slave device or the Modbus slave device does not respond, the Modbus gateway sends Modbus exception codes in exception responses messages to the Modbus TCP client.
  • Page 19: Modbus Registers

    The Modbus bus mapping documents for the individual SICAM devices use the register number to reference a piece of information in the Modbus register set. NOTE You find the Modbus bus mapping document (Excel table) for the SICAM Q200 devices under: http:// www.siemens.com/sicam-q200 SICAM, Multifunctional Recorder, Manual E50417-C1040-C606-A3, Edition 03.2017...
  • Page 20 Communication Modbus 2.4 Modbus Registers Only holding registers are used for SICAM Q200. All measured values, indications, metered values etc. are stored in these holding registers. Characterization of the register type (holding register) in the highest digit of the register number is not used in the Modbus documentation of SICAM Q200.
  • Page 21: Modbus Data Format

    Communication Modbus 2.5 Modbus Data Format Modbus Data Format Data Types - General 2.5.1 The following data types are used for storing variables in the Modbus registers. • Measured value • Date/time • Indication • Controllable indication • Counter • String NOTE The following convention applies when storing variables consisting of more complex data types to the...
  • Page 22 Communication Modbus 2.5 Modbus Data Format Status and Quality Information SICAM Q200 uses floating-point numbers with the exponent 255 (Inf, NaN) to display status information of the measured values: Table 2-3 Floating-point Numbers Floating-point Number State Remark (Hexadecimal) 7F800000H +Inf Overflow Measured value overflow 7F800001H...
  • Page 23: Data Type - Date/Time (Read And Write)

    20H set: Date/time error: equivalent to FAIL bit, see Device Manual SICAM Q200, chapter Time Synchroniza- tion. NOTE For the time synchronization via Ethernet, Siemens recommends the use of NTP. The date and time can be transmitted in 64-bit format or in 32-bit format. •...
  • Page 24: Data Type - Indications (Read)

    Communication Modbus 2.5 Modbus Data Format Data Type - Indications (Read) 2.5.4 Indications data type is represented by two bits in holding registers: [dw_Indications, 1, en_US] Figure 2-4 Data Type - Indications Where: • Q: status/quality bit: 0 = OK, 1 = invalid •...
  • Page 25: Data Type - Counter (Read)

    Communication Modbus 2.5 Modbus Data Format Use as Write Register [dw_ControllableIndications_Write, 1, en_US] Figure 2-6 Data Type - Controllable Indications - Write Register This data format enables up to 8 commands to be transmitted via the holding register for which the ON/OFF bits are set to either 0/1 or to 1/0.
  • Page 26 Communication Modbus 2.5 Modbus Data Format [dw_CounterQuality, 1, en_US] Figure 2-8 Data Type - Counter - Quality Information - Read Register Energy per Counter Pulse The energy per counter pulse is identical for all energy metered values calculated from the measured AC quan- tities so that only one value is transmitted for all energy counters.
  • Page 27: Communication Iec 61850

    Communication IEC 61850 General SICAM, Multifunctional Recorder, Manual E50417-C1040-C606-A3, Edition 03.2017...
  • Page 28: General

    “International Standard IEC 61850”. The device supports IEC 61850, Edition 2. You can find the following information about the communication protocol IEC 61850 server of the SICAM Q200 in separate documents under http://www.siemens.com/sicam-q200: • Logical nodes (Reporting of operational values) •...
  • Page 29: Glossary

    Glossary +Inf Stands for Infinity and denotes a measured-value overflow. Extremely large number or infinitely positive number Alternating Current Big-Endian format The most significant byte is stored first, that is at the memory location with the lowest address. Client Device in the communication network that sends data requests or commands to the server devices and receives responses from them CRC error Cyclic Redundancy Check: The cyclic redundancy check is a method of determining a test value for data (e.g.
  • Page 30 Glossary Limit violation A value exceeding or falling under a parameterized limiting value. Least Significant Bit Modbus The Modbus protocol is a communication protocol based on a client-server architecture. Modbus RTU Modbus Remote Terminal Unit: Modbus protocol type for transmitting data over serial networks (e.g. RS485) Modbus TCP Modbus Transmission Control Protocol: Modbus protocol type for transmitting data as TCP/IP packets;...