"4.1.4 Transmission rate"
Factory setting:
Setting range:
Purpose:
Description:
"4.1.5 Disconnect network"
Personal injury and damage to property
Activation of this function during operation interrupts the connection between the transmitter
or router and the network. Depending on the topology, this may result in failure of the
wireless HART network and also personal injury and/or damage to property. Therefore:
 Avoid inadvertent operations:
 Check on the gateway whether the device can be removed from the network without
Requirements:
Factory setting:
Setting range:
Purpose:
Description:
See also
"2.4 Cold restart" (Page 50)
"2.5 Reset device" (Page 51)
SITRANS TF280 WirelessHART
Operating Instructions, 10/2010, A5E02619566-02
60 s
Set transmission rate.
Setting of time intervals at which the transmitter sends measured values.
Increase or decrease the parameter value by pressing the ↑ or ↓ key.
Corresponds to parameter "1.4 Transmission rate" (Page 44) .
CAUTION
Make sure that the password input is always activated.
resulting in a failure or danger.
-
Interrupt communication of device with other network stations
Preparation for removal of device. The network and address parameters are
not deleted. Through activation of the parameter "4.1.3 Connect network"
(Page 54) the device reestablishes the connection.
Start this function by pressing the M key. Then: Execution depends on input
of PIN!
8 to 3600 s
Removal of device from the wireless HART network without danger is
guaranteed
PIN input function is active
START
Operation
5.6 Parameter descriptions
55