Installing the Cisco NCS 560-4 Router
Figure 43: RSP Installation
Step 5
Carefully slide the module into the slot until the EMI gasket on the module makes contact with the module
in the adjacent slot and both the ejector levers have closed to approximately 45 degrees with respect to the
module faceplate.
Caution
Step 6
While pressing down, simultaneously close both the ejector levers to fully seat the module in the backplane
connector. The ejector levers are fully closed when they are flush with the module faceplate.
Step 7
Tighten the two captive installation screws on the module. The recommended maximum torque is 5.5 in.-lb
(.62 N-m).
Note
Step 8
Verify that the captive installation screws are tightened on all of the modules installed in the chassis. This
step ensures that the EMI gaskets on all the modules are fully compressed in order to maximize the opening
space for the new or replacement module.
Note
Caution
If the top slot already has an RSP module installed, and you install a second RSP module in the slot
below it, be careful not to damage the EMI gasket of the bottom RSP module against the ejector
levers of the top RSP during insertion.
Make sure that the ejector levers are fully closed before tightening the captive installation screws.
If the captive installation screws are loose, the EMI gaskets on the installed modules will push
adjacent modules toward the open slot, which reduces the size of the opening and makes it difficult
to install the new module.
Blank module filler plates (Cisco part number N560-4-RSP-BLANK) should be installed in any
empty chassis slots to keep dust out of the chassis and to maintain consistent airflow through the
chassis.
Cisco NCS 560-4 Router Hardware Installation Guide