3. General data

3.3.2 RWH-(4.0-6.0)FSNFE

Model
Electrical power supply
Pump input power
Maximum current
Nominal water flow (condition 
Height
Unit
Width
dimensions
Depth
Height
Packaging
Width
dimensions
Depth
Net weight
Packaging dimensions
Refrigerant
Flow control
Compressor type
Quantity
Power
Refrigerant charge
Refrigerant pipe connection
Liquid pipe
Dimensions
Gas pipe
Water pipe connection
Inlet diameter
Space hea-
ting
Outlet diameter
Inlet diameter
DHW
Outlet diameter
Expansion vessel volume
Color
N O T E
• (*1): Dimensions with the minimum mounting foot height. This value can be adjusted up to +30 mm.
• (*2): Refrigerant liquid/gas piping accessory is factory-supplied in order to assist in the refrigerant pipe con-
nection. In this case the connection to the field refrigerant pipe must be brazed. For more information, please
refer to the Installation and operation manual.
60
TCGB0075 rev.0 - 11/2012
-
W
A
m³/h
)
mm
mm
mm
mm
mm
mm
kg
-
-
-
-
kW
kg
-
mm
mm
-
inch
inch
inch
inch
l
-
RWH-4.0FSNFE
RWH-5.0FSNFE
3N~ 400V 50Hz
140
15.0
1.7
706 (*1)
162
Microprocessor-controlled expansion valve
DC inverter driven hermetic scroll
1
3.0
Flare nut connection (*2)
Ø 9.53 (3/8")
Ø 15.88 (5/8")
Screwed connections
Flexible pipe (G 1" male)
Flexible pipe (G 1" male)
Flexible pipe (G 3/4" male)
Flexible pipe (G 3/4" male)
White (RAL 9016)
RWH-6.0FSNFE
140
140
15.0
15.0
2.1
2.4
595
695
837
770
720
167
167
0.46
R-134a
1
1
3.0
3.0
2.5
12