9. Preparations

» Flush the water line thoroughly.
Water installation
A safety valve is not required.
Taps
» Use suitable taps (see chapter "Appliance descrip-
tion / Accessories").
Note
Fitting the special aerator supplied provides an op-
timum water jet.

10. Installation

10.1 Installation site

Install the appliance in a room free from the risk of frost
and near the draw-off tap.
Ensure that the lateral fixing screws for the cover are
always accessible.
The appliance is only suitable for undersink installation
(water connections at the top).
DANGER Electrocution
Protection rating IP25 is only ensured if the appli-
ance back panel is fitted.
» Always fit the appliance back panel.
Installation - for contractors

10.2 Installation options

Undersink installation, pressure-tested, with
pressure-tested tap
Undersink installation, non-pressurised, with
non-pressurised tap