8. DISPLAY AND OPERATION
8.6.2 Operation example
(1) Parameter of 5 or less digits
The following example shows the operation procedure performed after power-on to change the home
position setting method (Parameter No.8) into the data setting type. Press "MODE" to switch to the
basic parameter screen.
To shift to the next parameter, press the "UP" or "DOWN" button.
When changing the parameter No.8 (home position return type) setting, change its set value, then
switch power off once and switch it on again to make the new value valid.
During flickering, press "MODE" for 2[s] to discard the new value and display the old value.
Press
MODE
four times. Select parameter No.8 with UP
The parameter number is displayed.
Press
UP
or
DOWN
to change the number.
Press
SET
twice.
The set value of the specified parameter number flickers.
Press
UP
twice.
During flickering, the set value can be changed.
Use
UP
or
DOWN
.
(
2: Data setting type)
Press
to enter.
SET
8 - 16
or
DOWN.