TM
ABB Ability
Smart Sensor EX User Manual
Smart Sensor XYZW
Smart Sensor variant
Description
XYZW
Smart Sensor BASA
Bluetooth, Standard Performance
Smart Sensor HCHC
WirelessHART, High performance, Long life
Smart Sensor BCHC
Bluetooth, High performance, Long life
TM
ABB Ability
Smart Sensor product coding XYZW:
X: Host comm. Type
Y: Power / battery
B: Bluetooth
A: 2.4 Ah battery
H: WirelessHART
C: 8.5 Ah battery
Smart Sensor is certified for mounting in mines (group I), gas hazard zone 0 (group IIC) and dust
hazard zone 20, indoor and outdoor, according to standards as defined below. For full standard
compliance see "Declaration of Conformity".
EN/IEC60079-0: 2018/2017, Explosive atmospheres:
EN/IEC60079-11:2012/2011, Explosive atmospheres:
EN 50303:2000
Figure 1
ABB Ability
TM
Smart Sensor Enclosure
1.
Marking on modules
I M1 Ex ia I Ma
II 1 G Ex ia IIC T4 Ga
II 1 D Ex ia IIIC T157°C Da
-40°C T
+85°C
amb
PRESAFE 19 ATEX 14930X
IECEx PRE 19.0044X
LR1608-1
WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD – SEE INSTRUCTIONS
AVERTISSEMENT - RISQUE DE CHARGE ÉLECTROSTATIQUE
- VOIR LES INSTRUCTIONS
Contained
FCC ID:2ANYT-SSPM00xAA
IC no: 23283-SSPM00xAA
0470
Smart Sensor xxxx
Serial number: C2xxxxxxxx
Article No: 4JNO000026R00x
BT MAC:
ABB AS 0666 Oslo Norway
WH MAC:
Ole Deviks vei 10
YYYY.MM
2.
Feasible locations for use of Smart Sensor
ABB Ability Smart Sensor is feasible for use in the following hazardous areas:
(a)
In-door and outdoor
(b)
Mines
(c)
Locations with danger for explosive gas
(d)
Locations with conductive or non-conductive dust
Article
Product
Number
Revision
4JNO000026R002
A
4JNO000026R003
A
4JNO000026R004
A
Z: Sensor & IO
W
Encapsulation type
:
S: Standard performance
A
H: High performance
C
Equipment – General requirements
Equipment protection by intrinsic safety "i"
Group I, Category M1 equipment intended to remain
functional in atmospheres endangered by firedamp and/or
coal dust
Cl I, Zn 0, AEx ia I Ma
Cl I, Zn 0, AEx ia IIC T4 Ga
Zn 20 , AEx ia IIIC T157°C Da
Cl I, Div 1, Gr A, B, C and D T4
Cl II, Div 1, Gr E, F and G T4
Cl III, Div 1
50:31:AD:XX:XX:XX
001B1E1A9AXXXXXX
3.
Special conditions for mounting hazardous areas
3.1
Earthing of sensor
To avoid possibility for buildup of charge on sensor, it is required to connect the sensor to
a metallic surface (with threaded hole for M6 or ¼'' 28 UNF screw) which is connected to
earth.
3.2
Avoidance of electrostatic discharge
Under dry conditions, the surface of the Smart Sensor may accumulate electrostatic
discharge. To avoid this to happen, the following precautions shall be done:
Avoid using a dry cloth when cleaning, or touching with other isolating objects (use
wet cleaning equipment)
Avoid installations locations with direct air flow, or protect from airflow
3.3
Mechanical damages
If enclosure is damaged by mechanical or chemical reasons, the sensor shall be
removed from Ex zone as soon as reasonable possible.
4.
Installation
4.1
Mechanical
Installation is done by using M6 or ¼'' -28 UNF socket head screws. Installation is done
on dedicated points with threaded holes pre-prepared on machine, or by using mounting
adapters for machine cooling ribs or for gluing on flat or curved surfaces.
For good connection to bearing vibrations, mounting on metal surface in direct
connection to bearing outer ring is recommended.
For best possible pickup of motor magnetic field, motor side mounting is recommended.
When installation in Ex zone, make sure that there is electric connection between sensor
metal base and machine below.
For detailed mounting instructions see "Smart Sensor Installation Manual" available on
the Smart Sensor product website.
WARNING:
Use a torque wrench, torque approx.. 10 Nm applied on the
screw, to give sufficient pressure between machine and sensor.
This gives good pickup of vibration and reduces risk for
loosening sensor by unintentional twisting.
4.2
Sensitivity to electric fields
Avoid having unshielded power cables crossing in the immediate proximity of the Smart
Sensor. This may create false high frequency vibration signals
5.
Environment
The operating temperatures are from -40°C to +85°C
IP degree IP66, dust tight and protected against powerful jets of water
Pollution degree 4 according to definition in IEC 61010-1, continuous conductivity
due to conductive dust, rain or other wet conditions
Air humidity 0% - 100% condensing
There are no restrictions on installation altitude
6.
Radio performance
Aim for free line of sight for optimal communication
Aim for installation with distance to ground (if possible >1 m)
See Smart Sensor User Manual available on product WEB page for detailed
information on how to achieve best possible radio performance
With WirelessHART, improved distance and performance can be achieved by
adding repeater sensors at good locations
7.
Radio certification statements
Modification statement:
Changes or modifications to the equipment will void the user's authority to operate the
equipment.
Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Class A Interference Statement
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
3BNP102777D017 G