Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide
First Published: 2014-08-13
Last Modified: 2019-03-28
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Nexus 9336PQ

  • Page 1 Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide First Published: 2014-08-13 Last Modified: 2019-03-28 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: https://www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company.
  • Page 3: Table Of Contents

    Preparing the Site Temperature Requirements Humidity Requirements Altitude Requirements Dust and Particulate Requirements Minimizing Electromagnetic and Radio Frequency Interference Shock and Vibration Requirements Grounding Requirements Planning for Power Requirements Airflow Requirements Airflow Requirements Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 4 Maintaining Transceivers and Optical Cables C H A P T E R 5 Replacing Modules Replacing a Fan Module During Operations Replacing a Power Supply Module Removing an AC Power Supply Removing a DC Power Supply Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 5 A P P E N D I X D Additional Kits Rack Mount Kit N9K-C9300-RMK A P P E N D I X E Site Preparation and Maintenance Records Site Preparation Checklist Contact and Site Information Chassis and Module Information Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 6 Contents Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 7: Preface

    Braces and a vertical bar within square brackets indicate a required choice within an optional element. Indicates a variable for which you supply values, in context where italics variable cannot be used. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 8: Related Documentation

    • Cisco Application Centric Infrastructure Fundamentals Guide • Cisco APIC Getting Started Guide • Cisco ACI Virtualization Guide • Cisco APIC REST API User Guide • Cisco APIC Command Line Interface User Guide Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide viii...
  • Page 9 • Cisco ACI System Messages Reference Guide • Cisco APIC Layer 4 to Layer 7 Services Deployment Guide • Cisco APIC Layer 4 to Layer 7 Device Package Development Guide • Cisco APIC Layer 4 to Layer 7 Device Package Test Guide •...
  • Page 10: Documentation Feedback

    What's New in Cisco Product Documentation, at: https://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Subscribe to What's New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation as an RSS feed and delivers content directly to your desktop using a reader application. The RSS feeds are a free service.
  • Page 11: Overview

    Overview, on page 1 Overview The Cisco Nexus 9336PQ ACI Spine Switch (N9K-C9336PQ) is a 2-rack-unit (RU) switch for the Cisco Application-Centric Infrastructure (ACI). This switch includes the following components: • 36 fixed 40-Gigabit Quad Small Form-factor Pluggable (QSFP+) ports •...
  • Page 12: Ports

    (RJ-45 port) chassis for locking the power supply end of the chassis to the bottom support brackets Console port (RJ232 port) Ports The switch chassis includes the following types of ports: Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 13: Fan Modules

    You can hot swap one of the power supplies during operations but otherwise must always have two power supplies (or one power supply and one blank faceplate) installed in the chassis to maintain the designed airflow. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 14 If they take in air from the hot aisle, the switch can overheat and shut down. All power supply and fan modules must use the same direction of airflow. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 15: Preparing The Site

    However, if the switch is located in an unusually humid location, use a dehumidifier to maintain the humidity within an acceptable range. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 16: Altitude Requirements

    Note To predict and prevent strong EMI, you need to consult experts in radio frequency interference (RFI). Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 17: Shock And Vibration Requirements

    The switch includes two power supplies (1-to-1 redundancy with current sharing) in one of the following combinations: • Two 1200-W AC power supplies • Two 1200-W HVAC/HVDC power supplies • Two 930-W DC power supplies Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 18 • Ensure that the protective devices are rated not greater than 30A when the switch is powered with regular DC power supplies (rated 48-60VDC). • Ensure that the protective devices are rated not greater than 10A when the switch is powered with HVDC power supplies (rated 240-350VDC). Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 19: Airflow Requirements

    The fan and power supply modules must have the same direction of airflow (even if their coloring is different). If you must change the airflow direction for the switch, you must shutdown the switch before changing the modules. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 20: Airflow Requirements

    • The depth of a four-post rack must be 24 to 32 inches (61.0 to 81.3 cm) between the front and rear mounting rails (for proper mounting of the bottom-support brackets or other mounting hardware). Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 21: Clearance Requirements

    Chassis Depth of the chassis Vertical rack-mount posts and rails Maximum extension of the bottom-support rails Chassis width Depth of the front clearance area (equal to the depth of the chassis). Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 22 Width of the front clearance area (equal to the width of the chassis with two rack-mount brackets that are attached to it). Note Both the front and rear of the chassis must be open to both aisles for airflow. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 23: Installing The Chassis

    You can install the switch using the following rack-mount options: • Rack-mount kit (N9K-C9300-RMK) which you can order from Cisco. You can install the switch in the following types of racks: •...
  • Page 24: Unpacking And Inspecting A New Switch

    The shipment should include the following: • Switch chassis, which includes the following installed components: • Two power supplies (any combination of the following with the airflow direction being the same as for the fan modules): Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 25: Planning How To Position The Chassis In The Rack

    For port-side exhaust airflow, the switch must have port-side exhaust fan and AC power supply modules with one or more of the following colorings: • Blue coloring on fan modules and AC power supplies • Gray coloring on DC power supplies Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 26: Installing The Chassis In A Four-Post Rack

    • Verify that you have 8 screws for attaching the bottom support brackets to the racks (typically M6 x 10 mm screws or the screw appropriate for the vertical mounting rails on the rack. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 27 (typically M6 x 10 mm screws) to secure that portion to the vertical mounting rails on the rack. Tighten each screw to the appropriate torque setting for the screws (for M6 x 10 mm screws, use 40 in. lbs [4.5 N·m] of torque). Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 28: Attaching Front-Mount Brackets To The Chassis

    You are ready to install two front-mount brackets on the chassis. Attaching Front-Mount Brackets to the Chassis You need to attach a right-angled bracket to each side of the chassis. This bracket holds the chassis in place on a four-post rack. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 29: Installing The Chassis In A Four-Post Rack

    Warning Statement 1074 Comply with Local and National Electrical Codes To reduce risk of electric shock or fire, installation of the equipment must comply with local and national electrical codes. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 30 If this happens, press the side rails toward the sides of the chassis so that the chassis stops can go inside the chassis and hold it in place on the rack. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 31: Grounding The Chassis

    You can also ground the chassis, which is required if the rack is not grounded, by attaching a customer-supplied grounding cable. Attach the cable to the chassis grounding pad and the facility ground. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 32 Step 3 Secure the grounding lug to the chassis grounding pad with two M4 screws, see the previous figure. Tighten the screws to 11 to 15 in-lb (1.24 to 1.69 N·m) of torque. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 33: Starting The Switch

    2. Remove the nuts from each of the terminal posts for the power supply. 3. Place the power cable negative-wire terminal ring on the negative terminal for the power source and secure them with a terminal nut. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 34 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series configuration guide.
  • Page 35: Connecting The Switch To The Aci Fabric

    Note To prevent sub-optimal forwarding between endpoints, connect every leaf switch in the fabric to every spine switch in the same fabric. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 36: Preparing To Connect To Other Devices

    Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
  • Page 37: Connecting Leaf Switches To Apics

    Connecting Leaf Switches to APICs You must downlink one or two (recommended for redundancy) Cisco Nexus 9300 platform ACI-mode leaf switches to each Application Policy Infrastructure Controller (APIC) in your ACI fabric. The type of virtual interface card (VIC) installed on the APIC determines the types of interface cables that you can use to connect the leaf switches to the APICs.
  • Page 38: Connecting Leaf Switches To Spine Switches

    Connect the other end of the interface cable to a downlink port on a leaf switch. • For a Cisco 10GBASE-LR or -SR transceiver and cable, insert the transceiver into a downlink optical port on a leaf switch before connecting the cable to the transceiver.
  • Page 39 • If there are modular switches in the fabric, their ACI-mode line cards must already be installed. The line cards can be of the following types: • 36-port 40-Gigabit (such as: N9K-X9736PQ) • 32-port 100-Gigabit (such as: N9K-X9732C-EX) (supported by Cisco Nexus 9504 and 9508 modular switches) • 36-port 100-Gigabit (such as: N9K-X9736C-FX) Note You cannot include NX-OS line cards in the same chassis when running in ACI mode.
  • Page 40: Installing A Gigabit Ethernet Module (Gem)

    First-generation Cisco Nexus 9000 Series switches include those switches that do not contain an EX or an FX in the PID (product identification). Second-generation Cisco Nexus 9000 Series switches include those switches that have an EX or an FX in the PID.
  • Page 41: Setting Up An Optional Console Interface

    Before you begin The console device must support VT100 terminal emulations and asynchronous transmissions. Step 1 Configure the terminal emulator program to match each of the following default port characteristics: • 9600 baud Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 42: Setting Up An Optional Management Connection

    DB-9 connector on the other end of the cable to the serial port on the console device. What to do next You can now perform the initial configuration for the switch (see the Cisco ACI Getting Started Guide). Setting Up an Optional Management Connection You can optionally set up an out-of-band management connection for monitoring and troubleshooting purposes.
  • Page 43: Maintaining Transceivers And Optical Cables

    Transceivers and fiber-optic cables must be kept clean and dust free to maintain high signal accuracy and prevent damage to the connectors. Contamination increases attenuation (loss of light) and should be below 0.35 dB. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 44 • Inspect routinely for dust and damage. If you suspect damage, clean and then inspect fiber ends under a microscope to determine if damage has occurred. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 45: Replacing Modules

    Step 1 Remove the fan module that you need to replace as follows: a) Unscrew the captive screw that secures the fan module to the chassis (see the following figure). Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 46 If you are not able to push the module all the way into the slot, carefully slide the module out of the slot Note and check its electrical connectors for damage. If damaged, contact Cisco Technical Assistance for help. If undamaged, repeat this step to reinstall the module.
  • Page 47: Replacing A Power Supply Module

    If the STS LED does not turn on, slide the module out of the chassis, and visually check the electrical connectors on the back side of the chassis for damage. If damaged, contact Cisco Technical Assistance for help. If undamaged, repeat the previous step to reinstall the module.
  • Page 48: Removing A Dc Power Supply

    Turn off the circuit breaker for the power feed to the power supply that you are replacing. Be sure that the LEDs turn off on the power supply that you are removing. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 49: Installing An Ac Power Supply

    (the end with the electrical connections) to the open power supply slot before carefully sliding the power supply all the way into the slot until it clicks into place. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 50: Installing A Dc Power Supply

    (the end with the electrical connections) to the open power supply slot before carefully sliding the power supply all the way into the slot until it clicks into place. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 51: Wiring A 48 V Dc Electrical Connector Block

    Strip 0.6 inches (15 mm) of insulation off the DC wires that you are using. Step 4 Orient the connector as shown in the following figure with the orange plastic button on top. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 52 "+ DC". Step 9 Verify that the other ends of the cables are attached to the DC power source and ground. You are then ready to turn on the DC power source. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 53: Rack Specifications

    • Standard 19-inch (48.3 cm) (two- or four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 54: Requirements Specific To Standard Open Racks

    • The roof should be perforated with at least a 20 percent open area. • The cabinet floor should be open or perforated to enhance cooling. The Cisco R Series rack conforms to these requirements. Cable Management Guidelines To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack.
  • Page 55: System Specifications

    17.5 inches (44.5 cm) 22.5 inches (57.1 cm) 3.5 inches (8.9 cm) (2 RU) Switch and Module Weights and Quantities Component Weight per Unit Quantity Cisco Nexus 9336PQ Chassis 24.3 lb (11.0 kg) (N9K-C9336PQ) Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 56: Switch Power Input Requirements

    Consumption (AC or DC) Requirement Cisco Nexus 9336PQ 400 W 660 W 2252.013 BTUs per hour Power Cable Specifications The following sections specify the power cables that you can order and use with this switch. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 57: 3-Kw Ac Power Cable Specifications

    16 A, 250 VAC Korea CAB-9K16A-KOR 16 A, 250 VAC South Africa CAB-9K16A-SA 16 A, 250 VAC Australia and New Zealand CAB-AC-16A-AUS 16 A, 250 VAC Peoples Republic of China CAB-AC-16A-CH 16 A, 250 VAC Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 58 Israel CAB-AC-2500W-ISRL 16 A, 250 VAC Japan and North America CAB-AC-2500W-US1 16 A, 250 VAC (nonlocking) 200-240 VAC operation Japan and North America CAB-AC-C6K-TWLK 16 A, 250 VAC (locking) 200-240 VAC operation Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 59 16 A, 250 VAC (IEC 60320 C19 to CEI 23-16) Taiwan CAB-AC-C19-TW 16 A, 250 VAC (IEC 60320 C19 to EL 218) All except Argentina, Brazil, NO-POWER-CORD No power cord is included with N.A. and Japan order. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 60: 3-Kw Universal Ac/Dc Power Cable Specifications

    3-kW Universal AC/DC Power Cable Specifications Locale Power Cord Part Number Cord Set Rating Power Cord Illustration Australia and New Zealand CAB-AC-16A-SG-AZ 16 A, 250 VAC (AU20LS3/Saf-D-Grid) CAB-AC-16A-SG-EU 16A, 250 VAC Israel CAB-AC-16A-SG-IS 16 A, 250 VAC Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 61 System Specifications Locale Power Cord Part Number Cord Set Rating Power Cord Illustration International/UK CAB-AC-16A-SG-IN 16 A, 250 VAC Italy CAB-AC-16A-SG-IT 16 A, 250 VAC South Africa CAB-AC-16A-SG-SA 16 A, 250 VAC Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 62 North America CAB-AC-20A-SG-C20 250 VAC 20 A North America CAB-AC-20A-SG-US 16 A, 250 VAC North America (non locking) CAB-AC-20A-SG-US2 250 VAC 20 A 200-240 VAC operation North America CAB-AC-20A-SG-US3 250 VAC 20 A Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 63 277 VAC 20 A operation International, CAB-HV-25A-SG-IN1 400 VAC 20 A Saf-D-Grid/Saf-D-Grid International, Ring Terminal CAB-HV-25A-SG-IN2 20A, 300 VAC/500 VDC source plug, Ring Terminal/Saf-D-Grid North America CAB-HV-25A-SG-US1 277 VAC/ 240 VDC/ 380 VDC 25 A Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 64: 3-Kw Dc Power Supply Power Cord Specifications

    Each 3-kW DC power supply requires four customer-supplied power cables (two negative cables and two positive cables). We recommend using six gauge cables. Cisco supplies 6-gauge lugs for connections to the power supply. You supply the connectors that are required to connect the cables to the DC power source.
  • Page 65: Leds

    Temperature exceeds the minor alarm threshold. The switch is not receiving power. Green Fans and power supply modules are operational. Amber At least one fan or power supply module is not operating. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 66: Fan Module Leds

    Power supply is on and outputting power to the switch. Flashing Power supply is connected to a power source but not outputting power to the green switch—power supply might not be installed in the chassis. Power supply is not receiving power. Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 67 Power supply warning—possibly one of the following conditions: • High voltage • High power • Low voltage • Power supply installed in chassis but not connected to a power source • Slow power supply fan Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 68 LEDs LEDs Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 69: Additional Kits

    Rack Mount Kit N9K-C9300-RMK The following table lists and illustrates the contents for the 2-RU rack-mount kit (N9K-C9300-RMK). Illustration Description Quantity Rack-mount kit • Bottom support rails (2) • Front-mount brackets (2) Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 70 Additional Kits Additional Kits Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 71: Site Preparation And Maintenance Records

    Your completion of each task ensures a successful switch installation. Planning Activity Verification Time and Date Space evaluation: Space and layout Floor covering Impact and vibration Lighting Physical access Maintenance access Environmental evaluation: Ambient temperature Humidity Altitude Atmospheric contamination Airflow Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 72: Contact And Site Information

    (transceivers) EMI evaluation: Distance limitations for signaling Site wiring RFI levels Contact and Site Information Use the following worksheet to record contact and site information for the installation. Contact person Contact phone Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 73: Chassis And Module Information

    Domain name IP broadcast address Gateway/router address DNS address Use the following worksheet to record information about the modules in the switch. Module Slot Module Type Module Serial Number Notes Fan module 1 Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...
  • Page 74 Site Preparation and Maintenance Records Site Preparation and Maintenance Records Module Slot Module Type Module Serial Number Notes Fan module 2 Fan module 4 Power Supply 1 Power Supply 2 Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide...

Table of Contents