hit counter script
Download Print this page
Siemens SIMATIC PG 760 Product Information Bulletin
Siemens SIMATIC PG 760 Product Information Bulletin

Siemens SIMATIC PG 760 Product Information Bulletin

Hide thumbs Also See for SIMATIC PG 760:

Advertisement

Quick Links

Product Information Bulletin
This leaflet gives you specific technical information
on your PG 760 programming device.

Advertisement

loading

Summary of Contents for Siemens SIMATIC PG 760

  • Page 1 Product Information Bulletin This leaflet gives you specific technical information on your PG 760 programming device.
  • Page 2 Trademarks SIMATIC and SINEC are registered trademarks of SIEMENS AG. The reproduction, transmission or use of this document or its contents is We have checked the contents of this manual for agreement with the not permitted without express written authority.
  • Page 3 Setting Up and Transporting the PG 760 Unpacking the Unpack your PG 760 programming device as follows: PG 760 1. Remove the packing. 2. Do no throw the original packing away. Keep it in case you have to transport the unit again sometime in the future. 3.
  • Page 4 Hardware Components of the PG 760 Front You can access all important operator controls and displays from the front of the unit. Rear Panel All the power supply connectors and interface ports for hooking up to (Connectors) external devices are located on the rear panel of the PG 760. Ventilator Power supply connector socket...
  • Page 5 Ports and Connectors Function Power supply connector Connection for power supply PS/2 mouse Connection for PS/2 mouse LPT 1 printer Connection for parallel printer Parallel interface MPI/DP Multipoint Interface (RS485)* Connection for S7 programmable COM 1 V.24/MODEM/PLC Connection for S5 programmable Serial port controller COM 2...
  • Page 6 Selecting Mains If the set voltage does not correspond with your local voltage, you must Voltage select the correct voltage by moving the mains voltage selector either to 115 V or 230 V. Caution Risk of damage to the unit! Operating the PG 760 with the incorrect mains voltage can damage the unit since the input voltage is also applied to the mains outlet.
  • Page 7 Drive Type The programming device PG 760 is equipped with a floppy disk drive, a hard disk drive and a CD-ROM drive as standard. SIMATIC Memory You can read, program and erase SIMATIC Memory Cards via the 68-pin Cards connector. Point of orientation SIMATC Memory Cards Figure 1-3...
  • Page 8 Diskette Drive You can store programs and data on diskettes with the disk drive and load them from diskettes into the PG 760. Types of Diskette You can use the following diskettes: Double-Sided High-Density Diskette Double-Sided Double-Density Diskette 3.5 in. 3.5 in.
  • Page 9 CD-ROM drive The CD-ROM drive enables you to easily update the already installed STEP 5, STEP 7 software and Windows 95. The CD-ROM drive is connected to the secondary IDE interface. Part Names and Functions BUSY Phones jack This jack is used to connect a set of headphones. Please use headphones with a stereo mini-jack plug.
  • Page 10: Digital Out

    Rear of the drive, The drive is configured as a Single. If you want to operate a second drive on this Configuration bus, you have to set either one of them as Master and the other as Slave or vice versa.
  • Page 11 Do not throw a new or discharged lithium battery into an open fire, do not solder onto the cell container. Do not recharge the battery, do not open the battery by force. The correct lithium battery is available from Siemens (Order No.: W79084-E1003-B1). Return used batteries to the manufacturer/recycler or dispose of them according to local regulations.
  • Page 12: Scroll-Lock

    Special Features of the Keyboard Autorepeat All keys on the keyboard are of the autorepeat type. That is, the relevant Function character is repeated as long as you keep the key pressed. Setting Up the The angle of inclination can be raised from 6 to 12 by using the swivel Keyboard feet on the back of the keyboard.
  • Page 13 Keys for The following keys take on S5-specific functions within the STEP 5 S5-Specific programming software. Functions Home Horizontal expand Vertical expand Insert Enter Cursor right or cursor left Input mode for segment title/comment Segment end Help Insert segment Delete segment (X Editing mode (CORR) Zoom-in (for GRAPH 5) Zoom-in (for GRAPH 5)
  • Page 14 Technical Specifications Safety Electromagnetic compatibility (EMC) Ambient conditions Mechanical specifications PG 760 Product Information Bulletin C79000-K7076-C761-03...
  • Page 15 Motherboard Drives Graphics Keyboard Interfaces Function displays PG 760 Product Information Bulletin C79000-K7076-C761-03...
  • Page 16 Directive 89/336/EEC on “electromagnetic compatibility”. The EC declarations of conformity and the documentation relating to this are available to the authorities concerned, according to the above EC Directive, Article 10 (1), from: Siemens AG Automation Group AUT E 14 Postfach 1963...
  • Page 17 ISO 9001 The quality assurance system for the whole product process (development, Certificate production, and marketing) fulfils the requirements of ISO 9001 (corresponds to EN29001: 1987). This has been certified by the German society for the certification of quality management systems (DQS). EQ-Net certificate no.: 1323-01 Software License The PG 760 is shipped with the software already installed.
  • Page 18 Risk of damage to the unit! Please note that only qualified personnel should be allowed to work on the open unit, so the warranty on the device is not affected. Authorized Siemens maintenance and repair centers offer you a specialist maintenance service.
  • Page 19 Risk of damage to the unit! Please note that only qualified personnel should be allowed to work on the open unit, so the warranty on the device is not affected. Authorized Siemens maintenance and repair centers offer you a specialist maintenance service. The addresses are listed at the end of this Product Information Bulletin.
  • Page 20 Correctly installed SIMM card Incorrectly installed SIMM card short circuit between contacts Caution Risk of short circuit! Make sure that the SIMM cards are properly installed, otherwise the mother board or the cards might be destroyed. Make sure that the SIMM contacts and the corresponding sockets are on top of each other.
  • Page 21 Phone If problems occur, the SIMATIC Hotline should be able SIMATIC Hotline should be able to help. to help. Direction: Direction: Siemens AG Siemens AG AUT 1 CS AUT 1 CS Gleiwitzerstr. 555 Gleiwitzerstr. 555 D-90475 Nürnberg-Moorenbrunn D-90475 Nürnberg-Moorenbrunn Phone:...