Operating the device and device functions

5.6 Extended device functions

5.6
Extended device functions
5.6.1

Monitoring functions

5.6.1.1

Overview of the monitoring functions

The basic version of the device also provides monitoring functions. The following display,
monitoring and control functions are available when the appropriate software is used:
● Temperature monitoring: Overtemperature, undertemperature, or cable break at a
temperature sensor
● Monitoring of drives with S.M.A.R.T. functionality
● Watchdog: Hardware or software reset of the computer
● Operating hours counter: Information about total time of operation
● Battery monitoring: The charge level of the battery is monitored.
SIMATIC IPC DiagBase software
Use the functions of the SIMATIC IPC DiagBase software included in the scope of delivery
for local monitoring. Use the "DiagBase Management Explorer" application to obtain a clear
overview of the controls. Use the DiagBase Alarm Manager to receive notifications about
individual alarms.
Note
For more information on SIMATIC IPC DiagBase software functionality, please refer to the
relevant Online Help.
SIMATIC IPC DiagMonitor software
SIMATIC IPC DiagMonitor is available on CD (not included in the scope of delivery). The CD
contains both the monitoring software and the software for the stations to be monitored. The
interface specifications and a library for creating your own applications are also provided.
5.6.1.2

Temperature monitoring/display

Three temperature sensors monitor the temperature of the device at several positions:
● Processor temperature
● Temperature close to the RAM ICs/chips
● Temperature in proximity of the air inlet
A temperature error is triggered under these circumstances:
● The configured low threshold for the temperature has been violated.
● The configured high threshold for the temperature has been violated.
86