Forced operation
Forced operation is used when the remote controller can't be used. The operation will be started
if the ON/OFF button is pressed. If you want to stop the operation, re-press the button.
Cooling
Model
Operating mode
Cooling
Indoor FAN Speed
Setting Temperature
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of
room temperature and resets in 18 minutes. During test operation, if remote controller signal is
received, the unit operates as remote controller sets. If you want to use this operation, Press and
hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 'beep'. If you want to stop the
operation, re-press the button.
Auto Restart Function
This function is useful in the situation of power failure.
When power regains after a failure this feature restore the previous operating condition
and the air conditioner will run in the same settings.
!
NOTE
This feature is enabled by factory default setting, but you can disable it by pressing the
ON/OFF button for 6 seconds. The unit will beep twice and the lamp will blink 6 times.
To enable it, press the button again for 6 seconds. The unit will beep twice and the blue
lamp will blink 4 times.
Room Temp. ≥ 24°C 21°C ≤ Room Temp. < 24°C
Cooling
High
High
22°C
22°C
ON/OFF
button
Heat pump Model
Healthy Dehumidification
High
23°C
ON/OFF
button
MAINTENANCE
19
Room Temp. < 21°C
Heating
High
24°C