Planning a Switch Data Stack
•
•
•
•
Tools and Equipment
Obtain these necessary tools and equipment:
•
•
Verifying Switch Operation
Before you install the switch in a rack, or on a table or shelf, you should power on the switch and verify
that the switch passes POST. See the "Running Express Setup" section in the getting started guide for
the steps required to connect a PC to the switch and to run Express Setup.
Powering Off the Switch
After a successful POST, disconnect the power cord from the switch. Install the switch in a rack, on a
table, or on a shelf as described in the
Planning a Switch Data Stack
Catalyst 3650 switches can share bandwidth by using data stacking.
•
•
•
•
•
Catalyst 3650 Switch Hardware Installation Guide
2-4
Operating environment is within the ranges listed in
Airflow around the switch and through the vents is unrestricted.
Temperature around the unit does not exceed 113°F (45°C). If the switch is installed in a closed or
multirack assembly, the temperature around it might be greater than normal room temperature.
Cisco Ethernet switches are equipped with cooling mechanisms, such as fans and blowers. However,
these fans and blowers can draw dust and other particles, causing contaminant buildup inside the
chassis, which can result in system malfunction. You must install this equipment in an environment
as free from dust and foreign conductive material (such as metal flakes from construction activities)
as is possible.
A number-2 Phillips screwdriver to rack-mount the switch.
A Torx T15 screwdriver, or the Torx T15 key that ships with StackWise upgrade kits, to install the
StackWise adapter.
Switch Stacking Guidelines, page 2-5
Data Stack Cabling Configurations, page 2-5
Data Stack Bandwidth and Partitioning Examples, page 2-6
Power-On Sequence for Switch Data Stacks, page 2-7
Changes to Switch Stack Membership, page 2-8
Appendix A, "Technical Specifications."
Chapter 2, "Installing the Switch,"
Chapter 2
Switch Installation
section.