hit counter script

Operating Modes; Exhaust Air Mode; Circulating-Air Mode; Operating The Appliance - Siemens LU17124 Instruction Manual

Table of Contents

Advertisement

Operating modes

This appliance can be used in exhaust-air mode or circulating-
air mode.

Exhaust air mode

The air which is drawn in is cleaned by the
grease filters and conveyed to the exterior
by a pipe system.
Note. The exhaust air must not be conveyed into a functioning
smoke or exhaust gas flue or into a shaft which is used to
ventilate installation rooms which contain heat-producing
appliances.
Before conveying the exhaust air into a non-functioning
smoke or exhaust gas flue, obtain the consent of the heating
engineer responsible.
If the exhaust air is conveyed through the outer wall, a
telescopic wall box should be used.

Operating the appliance

These instructions apply to several appliance variants. It is
possible that individual features are described which do not
apply to your appliance.
Note: Switch on the extractor hood when you start cooking and
switch it off again several minutes after you have finished
cooking. This is the most effective way of removing the kitchen
fumes.
Note: Fold the glass cover forwards. This increases the
extraction area.
Control panel
Explanation
1 Switches the fan on/off
2
Switches on fan speed 2
3
Switches on fan speed 3
Switches the lighting on/off
=
6

Circulating-air mode

The air which is drawn in is cleaned by the
grease filters and an activated carbon filter and
conveyed back into the kitchen.
Note: To bind odours in circulating-air mode, you must install
an activated carbon filter. The different options for operating the
appliance in circulating-air mode can be found in the brochure.
Alternatively, ask your dealer. The required accessories are
available from specialist outlets, from customer service or from
the Online Shop. The accessory numbers can be found at the
end of the instructions for use.

Setting the fan

Note: Always adjust the fan strength to meet current conditions.
If there is a large build-up of steam or fumes, select a high fan
setting.
Switching on
Press the
1 button.
a
1.
Note: If the fan is switched on, an LED lights up.
The fan starts up at the speed to which it was last set.
Press the 2 or 3 button to set another fan speed.
2.
Switching off
Press the
a
button.

Lighting

The lighting can be switched on and off independently of the
ventilation.
Press the
=
button.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lu17124q

Table of Contents