hit counter script

IBM x3250 M2 Problem Determination And Service Manual page 180

Hide thumbs Also See for x3250 M2:
Table of Contents

Advertisement

Table 10. DSA diagnostic messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 3, "Parts listing, Types 4190, 4191 and 4194 server," on page 31 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained
service technician.
Message
number
Component
166-823-xxx
BMC
162
IBM System x3250 M2 Types 4190, 4191 and 4194: Problem Determination and Service Guide
Test
State
BMC I2C Test
Aborted
Description
Action
BMC I2C test
1. Turn off the system and disconnect it
canceled: cannot
from the power source. You must
execute the
disconnect the system from ac power to
command;
reset the BMC.
insufficient
2. After 45 seconds, reconnect the system
privilege level.
to the power source and turn on the
system.
3. Run the test again.
4. Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
5. Make sure that the BMC firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in
the Firmware/VPD section for this
component. For the latest level of
firmware, go to http://www.ibm.com/
support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system
to display a matrix of available
firmware.
6. Run the test again.
7. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.

Advertisement

Table of Contents
loading