9.
COOLANT OPERATION
Coolant used in the machine can be used by means of operation as follows
9.1
Connecting coolant motor and peripheral device
In general, coolant motor, pressure switch and oil skimmer etc. are attached to coolant tank.
Connectors for fitting related to coolant are prepared as follows in the lateral side of
electrical control cabinet. More detail explanation, refer to the electric diagram.
Classification
General coolant motor
Optional coolant motor
Cool-Jet motor
Coolant pressure
Oil skimmer
Optional coolant motor and Cool-Jet motor cannot be attached simultaneously.
9.2
Standard coolant operation
Standard coolant can be manually operated using the switch in operation panel as follows.
The operation method is same with upper and lower unit.
(1) Standard coolant manual operation
1) Coolant "ON"
1
2
Connector spec. in box
MS3102A-18-10S
MS3102A-24-11S
MS3102A-18-10S
MS3102A-18-4S
MS3102A-18-9S
[Conditions for coolant operation]
Check the status of machine satisfies the conditions
as follows.
- The machine is in machine ready status.
- The front door is closed.
- The status that coolant pressure alarm isn't
occurred.
[Coolant "ON" command]
Press the start switch shown in left side, then coolant
is outgoing and the lamp in switch will be ON.
Check the lamp in stop switch shown in left side is
OFF. If not, press switch and then OFF the lamp.
.
Wiring No.
Std. / Opt.
WM0410
Standard
WM0420
Option
WC0440
Option
WC0410
Option
WM0750
Option
OPERATION | 61