hit counter script

Advertisement

Quick Links

PolyBlend
PB50-0.4
Siemens Water Technologies Corp.
PO Box 389
Bradley, IL 60915
(815) 932-8154 Phone
12/06
(815) 932-0674 Fax

Advertisement

Table of Contents
loading

Summary of Contents for Siemens PolyBlend PB50-0.4

  • Page 1 PolyBlend PB50-0.4 Siemens Water Technologies Corp. PO Box 389 Bradley, IL 60915 (815) 932-8154 Phone 12/06 (815) 932-0674 Fax...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PolyBlend PB50-0.4 OVERVIEW Safety Precautions....................1 Specifications......................1 INSTALLATION Location........................1 Unpacking .......................1 Connections......................1 Storage ........................1 OPERATION General........................2 Start-Up ........................2 Water Pressure ......................2 Solution Output .......................2 MAINTENANCE Shutdowns ......................3 Maintenance......................3 Special Tools ......................3 Lubrication.......................3 Predicted Life Span....................3 Operating Procedures....................3 Emergency Operating Procedures ................3 Disassembly, Repair and Reassembly ................3...
  • Page 3: Overview

    WATER TECHNOLOGIES TELEPHONE 815-932-8154 P.O.BOX 389 800-882-6466 BRADLEY, IL 60915 FACSIMILE 815-939-9845 PolyBlend Model #PB50-0.4 INSTALLATION, OPERATION, AND MAINTENANCE INFORMATION CONTENTS INSTALLATION Overview Warranty LOCATION Installation Appendixes Operation Drawings Select a location that provides: Maintenance • Electrical Supply • Potable Water (Clean) READ THIS MANUAL BEFORE YOU •...
  • Page 4: Operation

    Step 7: Adjust water flow at mixing chamber by OPERATION turning control valve. (The other control valve should be turned for post-dilution adjustment, GENERAL if applicable.) This PolyBlend unit will perform the following NOTE: Do not run polymer pump unless functions: meter polymer dosage, regulate mixing water, provide uniform dilution and activation, operate water flow is established.
  • Page 5: Maintenance

    Emergency operating instructions do not apply to If out of service for more than two weeks, flush pump Siemens Water Technologies – Stranco Products and mixing chamber. equipment. In case of an emergency, TURN OFF POWER TO STOP RUNNING.
  • Page 6: Troubleshooting

    TROUBLESHOOTING Symptom Possible Cause Corrective Action • • No Water Flow Closed Valve on Water Supply Make sure valve is open • • Blocked Solenoid Valve Dis-assemble and clean valve • • Closed or clogged discharge line Remove any blockages or open any closed valves •...
  • Page 7: Warranty

    Siemens Water Technologies. If the and/or actual operating conditions (this exclusion customer gives Siemens Water Technologies shall not apply if all necessary design information Corp.
  • Page 8 AND ANY AFFILIATED COMPANIES SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, SPECIAL, PUNITIVE OR OTHER INDIRECT DAMAGES, AND SIEMENS WATER TECHNOLOGIES' TOTAL LIABILITY ARISING AT ANY TIME FROM THE SALE OR USE OF THE EQUIPMENT SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE EQUIPMENT.
  • Page 9: Differential Pressure Switch

    Differential Pressure Switch Location of Differential Pressure Switch The high pressure port connects to the inlet manifold between the solenoid valve and the rotameter/rate-adjusting valve. The low pressure port connects to the discharge side of the rotameter. Function of Differential Pressure Switch The differential pressure switch ensures sufficient water flow is present before the polymer pump is energized.
  • Page 10 Differential Pressure Switch Adjusting the Differential Pressure Switch Adjust the PolyBlend differential pressure switch only if pressure and flow to the system are adequate. The adjustment logic is the opposite of what you might expect. The PolyBlend differential pressure switches have a red light (on the left side) that lights up whenever source water flow is too low and the polymer pump is disabled.
  • Page 11: Digital Display Controller (Rem-1E)

    In the internal mode, output is 0-100 strokes-per- remotely located, using standard cable/connector hour (sph) or 0-100 strokes-per-minute (spm). A sets available from Siemens. touch of the pressure-sensitive keys varies the The REM-1E Digital Display Pump Controller Offers: •...
  • Page 12 Siemens Water Technologies 595 Industrial Drive Literature No. ST-REM1E-DS-0606 815.929.4101 tel. Bradley, IL 60915, USA Bradley, IL 60915 www.usfilter.com Subject to change without notice. stranco.water@siemens.com ©2006 Siemens Water Technologies Corp.
  • Page 13: Lmi Diaphragm Pump Information

    - Length of hose or tubing (same I.D. as DIAPHRAGM PUMP INFORMATION pump ports) WARNING: ALWAYS wear protective 1. Maintain all usual connections to the clothing, face shield, safety glasses and gloves PolyBlend unit except disconnect the polymer when working near or performing and suction line at pump input.
  • Page 14 PRESSURE CONTROL (B and C series only) A capped potentiometer is located on the face plate of the diaphragm pump. This potentiometer is for pressure control or power to the pump solenoid. Since the PolyBlend unit is equipped with a 20 PSI backpressure/check valve, the potentiometer should be set for full power or full clockwise.
  • Page 15 Seal Ring, Ball and Injection Check Valve Seal Ring, Ball and Injection Check Valve Spring Replacement Spring Replacement 1. Carefully depressurize, drain and disconnect the discharge and suction lines. Place the suction tubing into a container of mineral oil. Turn the pump on to flush the head assembly. After flushing, lift the suction tubing out of the mineral oil and continue to pump air into the pump head until the pump head is purged.
  • Page 16 Type I – Push on Knob Type III Collet Knob Rezeroing and Stroke Knob Disassembly and Rezeroing and Stroke Knob Disassembly and Assembly Assembly 1. Remove stroke knob from the pump by 1. Remove yellow cap. grasping the knob firmly and pulling it toward you.
  • Page 23: Overall Parts List And Exploded Diagram

    OVERALL ITEM P/N DESCRIPTION QTY UM 10342 TUBING, 3/8" OD X 1/4" ID, POLYETHYLENE 1.00 10746 BRACKET, PUMP 2.00 1364001 BASE SUB-ASSY. PB100-0 1.00 1450318 BELT 1.00 1600312 BOLT, HH, 1/4-20 X 3/4 SS 8.00 1600324 BOLT, HH, 1/4-20 X 1-1/2 SS (CAP SCREW) 2.00 1600366 BOLT, HH, 1/4-20 X 1 SS...
  • Page 24 16/50 D-001...
  • Page 25: Mixing Chamber Assembly Parts List And Exploded Diagram

    MIXING CHAMBER 2340101 ITEM PART NO. DESCRIPTION QTY. 1410002 BEARING 1414001 BEARING, THRUST 1419001 BEARING, FLANGE CARRIER 2124002 CAP, TOP, MIXING CHAMBER 2124003 CAP, BOTTOM, MIXING CHAMBER 2650001 COLLAR, 1/2" I.D. 2650002 COLLAR, 3/4" I.D. 5173304 IMPELLER 5173305 IMPELLER, SECONDARY 5551002 LABEL - DISCHARGE 6020031...
  • Page 26 MC-0101...
  • Page 27: Flowmeter Assembly Parts List And Exploded Diagram

    FLOWMETER ASSEMBLY – P/N 4300103 ITEM PART NO. DESCRIPTION QTY. 4290103 FLOWMETER, KING, 50GPH 6091301 O-RING, BUNA N 1040093 ADAPTER, SPUD 2735634 CONNECTOR, TUBE, 1/4" FPT X 3/8" OD COMP. 1048401 ADAPTER, FLOWMETER 9579301 VALVE, KING FM-0103...
  • Page 28 Blank Page...
  • Page 29: Pump Assembly Parts List And Exploded Diagram

    Supplement Instruction Series AA7 Electronic Metering Pump Metering Pump Component Diagram 201 Ivyland Road Ivyland, PA 18974 USA TEL: (215) 293-0401 FAX: (800) 327-7563 http://www.Imipumps.com ISO 9001 Certified 1975.A 08/03...
  • Page 30 Series AA7 Drive Assembly Exploded View Diagram...
  • Page 31 Series AA7 Drive Assembly Parts List Key No. Model Series Part No. Description Qty. Key No. Model Series Part No. Description Qty. 37879 Foot AA741, AA751, AA761, AA771, AA781 48016 Control Panel Assembly, 115V 38199 Screw AA742, AA752, AA762, AA772, AA782 34497 O-Ring AA743, AA753, AA763, AA773, AA783...
  • Page 32 Series AA7 Control Panel Detail Series AA7 Wiring Diagram ' 2003 LMI Milton Roy - USA- All Rights Reserved Printed in USA Specifications subject to change without notice.
  • Page 33: General Arrangement Pb16, Dwg. # Pb100

    ROTAMETER RANGE PB UNIT PUMP OUTPUT VOLTAGE PB16-0.4 0-0.42 GPH 1-16 GPH 120VAC/1PH/60Hz 240VAC/1PH/50Hz PB16-0.4A 0-1.59 LPH 3.8-60 LPH PB16-1 0-1 GPH 1-16 GPH 120VAC/1PH/60Hz 0-3.8 LPH 3.8-60 LPH 240VAC/1PH/50Hz PB16-1A 120VAC/1PH/60Hz PB16-2 0-2 GPH 1-16 GPH PB50-0.4 0-0.42 GPH 4-50 GPH 120VAC/1PH/60Hz 240VAC/1PH/50Hz...

Table of Contents