14. Maintenance

DANGER Electrocution
Before any work on the appliance, disconnect all
poles from the power supply.
14.1 Draining the appliance
DANGER Scalding
Hot water may escape during the draining process.
If the appliance needs to be drained for maintenance or to
protect the whole installation when there is a risk of frost,
proceed as follows:
» Close the shut-off valve in the cold water inlet line.
» Open the draw-off valve.
» Undo the water connections on the appliance.
14.2 Cleaning the strainer
You can clean the fitted strainer after removing the cold
water supply pipe.
34
14.3 Tests in accordance with
VDE 0701/0702
Earth conductor check
» Check the earth conductor (in Germany e.g.
DGUV A3) on the earth conductor contact of the
power cable and on the appliance connector.
Insulation resistance
» If an appliance with a rated heating output of
> 3.5 kW does not achieve an insulation resistance
of 300 kΩ, we recommend that the insulating prop-
erties of the appliance are checked by conducting a
differential current test of the earth conductor cur-
rent / leakage current to VDE 0701/0702 (Fig. C.3b).
14.4 Appliance storage
» Store the dismantled appliance in a room free from
the risk of frost, as water residues remaining inside
the appliance can freeze and cause damage.
14.5 Replacing the power cable for the
MTD 570
» If replacing the cable for the MTD 570, use a power
cable with 4 mm² cross-section.