Summary of Contents for ABB Sense7 Series
Page 1
Original instructions Sense7-series Non-contact coded safety switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety...
Page 2
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of ABB JOKAB SAFETY for any act exceed the individual price of the product on which liability asserted.
This document is intended for authorized installation personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: • Basic knowledge of ABB Jokab Safety products. • Knowledge of safety devices and safety locks. •...
IP69K and can be high pressure hosed with detergent at high temperature. Warning! Application consideration must be given to the fixing of the actuator which has to be in a way that prevents disassembly by easy means. 2TLC172249M0201, rev. B www.abb.com/jokabsafety 2013-04-10...
Connections See Chapter Installation and Maintenance for more information regarding installation. Connection For all ABB switches the NC circuits are closed when the guard is closed and the actuator present. BLUE (24VDC) (0VDC) BLACK (IN) & POWER Circult 1 WHITE (OUT) YELLOW (IN) &...
Installation and maintenance Installation and maintenance 1. The installation of all ABB Jokab Safety interlock switches must be done in accordance with a risk assessment for the individual application. Installation must only be carried out by competent personnel and in accordance with these instructions.
In some cases, T might be reduced by the opening time of the guard until the opening size permits access of the relevant parts of the body. Refer to EN ISO 13855 for further details and EN ISO 13857 for specified values. 2TLC172249M0201, rev. B www.abb.com/jokabsafety 2013-04-10...
Technical data Manufacturer Address ABB AB / JOKAB SAFETY Varlabergsvägen 11 SE-434 39 Kungsbacka Sweden Electrical characteristics Minimum switched current 10VDC 1mA Dielectric withstand 250 VAC Safety channel 1-NC 24VDC 0.2 A max. rating Safety channel 2-NC 24VDC 0.2 A max. rating Safety channel 3-NO 24VDC 0.2 A max.
Page 13
47 years MTTF 470 years (8 cycles per hour/24 hours per day/365 days) Certifications TÜV, cULus Information with regard to UL 508 Type 1 Enclosure Control No: 48W5 Max.Temp: 70ºC (Plastic version), 90ºC (Stainless Steel) 2TLC172249M0201, rev. B www.abb.com/jokabsafety 2013-04-10...