Drives; Removing A Drive Blank - Dell EMC PowerEdge R450 12M1H Installation And Service Manual

Table of Contents

Advertisement

Steps
1. Align and insert the intrusion switch module until it is firmly seated in the slot on the system.
2. Using the Phillips #1 screwdriver, tighten the screw securing the intrusion switch module.
3. Connect the intrusion switch cable to the connector on the system board.
NOTE:
Route the cable properly when you replace it to prevent the cable from being pinched or crimped.
Figure 26. Installing the intrusion switch
Next steps
1.
Install the air
shroud.
2. Follow the procedure listed in

Drives

Removing a drive blank

Prerequisites
1. Follow the safety guidelines listed in the
2. If installed,
remove the front
CAUTION:
To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
Steps
Press the release button, and slide the drive blank out of the drive slot.
After working inside your
Safety
instructions.
bezel.
system.
Installing and removing system components