hit counter script

Rfid Passive Tag - Honeywell BK-G40 Instruction Manual

Industrial diaphragm gas meters
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Honeywell
Connecting the pulse generator:
 Attach the pulse generator in the opening
located on the bottom of the index and swing it
into the sealable plug connector on the right-
hand side of the index. Now secure it with the
enclosed rivet and seal (for this you will need a
pair of sealing pliers or a similar tool).
 Pull the locking pin provided with a snap
mechanism out of its guide (only for IN-Z61).
 Then connect the plug at the end of the prefabricated cable in the
designated opening on the bottom of the pulse generator.
 Secure the plug by re-inserting the locking pin into its guide (only for IN-
Z61).
 Assign the terminals in accordance with the pin assignment on the pulse
generator.
 IN-Z61, IN-Z62, IN-Z63, IN-Z64 and IN-Z65 can be retrofitted onto the Z6
index at any time without breaking the metrological seal.

6. RFID passive tag

WARNUNG!
The following conditions apply to meters marked with  and fitted
with an RFID passive tag:
 Under standard EN 60079-14, they must not be used in an
environment with high electromagnetic fields with an effective
value of over 1 A/m or 3 V/m.
 The RFID devices required for reading must be certified
separately for the appropriate explosion-hazard areas or may
only be used in safe areas.
 The transmission rating of the RFID readers must not exceed
the maximum limits set out in EN 60079-14.
16
73020212j
© Elster GmbH | All rights reserved. Subject to modification

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bk-g65Bk-g100

Table of Contents