INSTALLING THE INDOOR UNIT
Electrical Connections
1
Open the front panel.
2
Take off the cover as indicated in the piciure (by
removing a screw or breaking the hooks).
3
For the electrical connections, see the circuit
diagram on the right part of the unit under the
front panel.
4
Connect the cable wires to the screw terminals
by following the numbering, use wire size
suitable to the electric power input (see name
plate on the unit) and according to all current
national safety code requirements.
WARNING
• The cable connecting the outdoor and indoor
units must be suitable for outdoor use. (code
designation 60245 IEC 57)
• The plug must be accessible also after the
appliance has been installed so that it can be
pulled out if necessary.
• An efficient earth connection must be ensured.
• If the power cable is damaged, it must be replaced
by an authorised Service Centre.
NOTE
• Optional the wires can been connected to
the main PCB of indoor unit by manufacturer
according to the model without terminal block.
Front panel
Wiring diagram
Terminal block cover
N
1
Inter-Connecting Cable
WARNING
• Loose screws may cause electrical sparks, injury,
and death.
CAUTION
• Without exception, install an independent power
circuit specifically designed for the appliance.
Refer to the circuit diagram attached inside the
control cover for where to connect the cable.
• Screw connections in the appliance's control
box can vibrate loose during transporting and
operating the appliance. Check that all the
connections in the appliance are securely fixed at
all times. (If they have loosened, both the wire and
the termination can be broken.)
NOTE
• Circuit diagrams may be altered by the
manufacturer without any notification.
• The feature may be changed according to the type
of model.
EN
L
17