18 INSTALLATION
Wall Cap Type
Use for only short run installations
b
b: 2 1/2 '' (6.4 cm)
NOTE
• Deduct 6 ft. (1.8 m) for each additional elbow. Do not use more than four 90° elbows.
• In Canada, only those foil-type flexible ducts, if any, specifically identified for use with the appliance by
the manufacturer should be used. In the United States, only those foil-type flexible ducts, if any,
specifically identified for use with the appliance by the manufacturer and that comply with the Outline
for Clothes Dryer Transition Duct, Subject 2158A, should be used.
Routing and Connecting Ductwork
Follow the guidelines below to maximize drying
performance and reduce lint buildup and
condensation in the ductwork. Ductwork and
fittings are NOT included and must be purchased
separately.
• Use 4'' (10 cm) diameter rigid, semi-rigid or
flexible metal ductwork.
• The exhaust duct run should be as short as
possible.
• Use as few elbow joints as possible.
• The male end of each section of exhaust duct
must point away from the dryer.
• Use duct tape on all duct joints.
• Insulate ductwork that runs through unheated
areas in order to reduce condensation and lint
buildup on duct surfaces.
• Incorrect or inadequate exhaust systems are not
covered by the dryer warranty. Dryer failures or
service required because of such exhaust
systems will not be covered by the dryer
warranty.
Number of 90°
Maximum length of 4-inch diameter rigid
Elbows
0
1
2
3
4
Correct Venting

Connecting Gas Dryers

WARNING
• To reduce the risk of fire or explosion, electric
shock, property damage, injury to persons, or
death when using this appliance, follow
requirements including the following:
Electrical Requirements for Gas
Models
WARNING
• This dryer is equipped with a three-prong
grounding plug for protection against shock
hazard which should be plugged directly into a
properly grounded three-prong receptacle. Do
metal duct
55 ft. (16.8 m)
47 ft. (14.3 m)
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)