Super heat recovery multi, indoor/outdoor unit, 1-way / 2-way / 4-way air discharge cassette type, floor standing cabinet type, for commercial use (220 pages)
Page 1
AIR CONDITIONER (MULTI TYPE) Outdoor Unit For commercial use Owner’s Manual Model name: MMY-MAP0806FT8P-E MMY-MAP1006FT8P-E MMY-MAP1206FT8P-E MMY-MAP1406FT8P-E MMY-MAP1606FT8P-E MMY-MAP1806FT8P-E MMY-MAP2006FT8P-E MMY-MAP0806FT8JP-E MMY-MAP1006FT8JP-E MMY-MAP1206FT8JP-E MMY-MAP1406FT8JP-E MMY-MAP1606FT8JP-E MMY-MAP1806FT8JP-E MMY-MAP2006FT8JP-E Scan QR CODE to access installation and owner’s manual on website. https://www.toshiba-carrier.co.th/manuals/default.aspx Manual are available in AR/BG/CS/DA/DE/EL/EN/ES/ET/FI/FR/ HR/HU/IT/LT/LV/NL/NO/PL/PT/RO/RU/SK/SL/SV/TR.
– 1 – ■ Information on the transportation, handling and storage of the Original instruction carton Thank you very much for purchasing Air Conditioner. Please read this Owner’s Manual carefully before using your Air Conditioner. • Be sure to obtain the “Owner’s Manual” and “Installation Manual” from contractor (or dealer). Examples of indication on the carton •...
■ Connectable indoor units Part names of outdoor and indoor units ■ Outdoor unit Model type Model Name 4-way cassette MMU-AP✽✽✽✽H✽ Compact 4-way cassette MMU-AP✽✽✽✽MH✽ 2-way cassette MMU-AP✽✽✽✽WH Air discharge MMU-AP✽✽✽✽YH✽ Warm air comes out when cooling, and cool air 1-way cassette MMU-AP✽✽✽✽SH✽...
Page 4
– 3 – ◆ 2-Way Cassette Type ◆ Concealed Duct Standard Type MMD-AP✽✽✽H✽ Earth screw Air discharge Return air grille Equipped on the electrical control Connect a discharge duct. box. Air in the room is taken in through here. Electrical control box The earth screw is provided in the electrical control box.
Page 5
◆ Floor Standing Cabinet Type MMD-AP0726H✽ to AP0966H✽ Air discharge Discharge louver Connect a discharge duct. Controls discharge air directions. Electrical control box Earth screw Air fi lter The earth screw is provided in the Equipped on the electrical control box. Filters out dust.
– 5 – Part names and functions of the remote controller This remote controller can control up to 8 indoor units. ■ Display section All indicators are displayed in the display example below. Actually, only the selected options will be displayed. Display •...
Page 7
■ Operation section Once the settings have been confi gured, all you need to do is push the button from then on. button (Unit/Louver select button) Selects a unit number (left) and louver number (right). button (Fan speed select button) Operation lamp UNIT button: Selects the desired Fan speed.
– 7 – ■ ■ Changing the set temperature Power save operation Basic operation Push the “TEMP. ” buttons. • When you use the air conditioner for the fi rst time or change the settings, follow the procedures below. Push to increase the temperature, and From next time, pushing the button starts running of the air conditioner with the chosen settings.
Timer operation Installation ■ Select a timer type from the following three: (Max. 168 hours) Ask the installation company about important points of Be careful of operation sounds OFF timer : Stops running after the specifi ed period. general instruction. Repeat-OFF timer : Stops running after the specifi...
– 9 – ■ Cooling / Heating operations Notes on operations and performance • When the outdoor temperature goes out of the operable range, cooling or heating operation may not ■ ■ Check before operation Protective device be performed in order to protect the equipment. In this case, “...
■ ◆ To stop swinging 4-way cassette type only Louver direction ◆ To set the louvers individually Push the button at the desired position ■ 4-way cassette type, 2-way NOTE while the louver is swinging. Push the button (left side of the button) cassette type, 1-way cassette •...
Page 12
– 11 – ◆ Setting the louver lock ▼ Cyclic swing (Recommended for cooling) Push the button. Push the button to confi rm the direction All four louvers swing at different times like waves. of the selected louver. Push the button to fi...
Page 13
■ ■ ◆ Releasing the louver lock 4-Way Cassette Type 2-Way Cassette Type Set “0000” in Step 4 of “Setting the louver lock”. ▼ When cooling ▼ When cooling mark disappears Point the louver horizontally. Point the louver horizontally to send cool air across the entire room.
Page 14
– 13 – ■ ■ Ceiling Type 1-Way Cassette (YH series), NOTE NOTE and fl oor Standing Types 1. When sending air downward, bend the louvers To improve the cooling/heating performance, change Vertical adjustment evenly as shown in the following fi gure. If the air the louver angle for each operation.
Page 15
■ ■ ■ 1-Way Cassette Type Floor Standing Type Floor Standing cabinet Type ◆ Changing the air discharge (YH series) Follow the procedure below to change the air Vertical adjustment discharge: Vertical adjustment ▼ When cooling Remove the two fi xing screws of the air Move the louver manually and point it horizontally to discharge.
– 15 – Tips for saving energy and comfortable Maintenance performance WARNING To save energy and perform comfortable cooling and heating For daily maintenance including Air Filter cleaning, make sure to ask the qualifi ed service person particularly following models; •...
Page 17
■ ■ ◆ Floor standing cabinet type Cleaning the indoor unit and Before the cooling season Vacuum dust or brush clean. • If heavily stained, it is more effective to wash in remote controller Ask a qualifi ed service person to clean the drain lukewarm water mixed with neutral detergent.
– 17 – CAUTION Troubleshooting If any of the following conditions occur, turn off the main power supply switch and immediately contact the dealer: When the following symptoms are found, check the points described below before asking repair servicing. • Switch operation does not work properly. •...