Appendix A
Specifications
2. Pin 7 can be used as a DCD input for connection to a modem. The RJ-45-to-DB-25F adapter maps DCD to this pin when used
Alarm Port
The dry relay alarm port operates up to 50V AC/DC maximum and up to 80 mA maximum. Total power
dissipation should not exceed 300 milliwatts. The normally closed position will have from 15 to 30 ohms
resistance. The open position will be greater than 1 megohm. The alarm condition is the closed position.
This port is a switch so that the cable connector can be inserted in either orientation.
Lithium Battery Caution
Caution
ADVARSEL!
VAROITUS
ADVARSEL
VARNING
OL-5418-07
with a straight-through cable.
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the manufacturer. Dispose
of used batteries according to the manufacturers instructions.
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med
batteri af samme fabrikat og type. Levér det brugte batteri tilbage tilleverandøren.
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan
valmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mikaisesti.
Eksplosjonsfare ved feilaktig skifte av batteri. Benytt samme batteritype eller en
tilsvarende type anbefait av apparatfabrikanten. Brukte batterier kasseres i henhold til
fabrikantens instruksjoner.
Eksplosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ
som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens
instruktion.
Cisco 7301 Installation and Configuration Guide
Alarm Port
A-9