Page 3
Contents Safety notices......................v Installing the IBM Power S1012 (9028-21B)............1 Installing a rack-based server........................1 Prerequisite for installing the rack-mounted server................1 Completing inventory for your server....................1 Determining and marking the location in the rack................2 Attaching the mounting hardware to the rack..................6 Installing the system into the rack......................
Page 5
Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: If IBM supplied the power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product. Do not open or service any power supply assembly.
Page 6
• Each rack cabinet might have more than one power cord. – For AC powered racks, be sure to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing. vi Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 7
– For racks with a DC power distribution panel (PDP), turn off the circuit breaker that controls the power to the system unit(s), or disconnect the customer’s DC power source, when directed to disconnect power during servicing. • Connect all devices installed in a rack cabinet to power devices installed in the same rack cabinet.
Page 8
In addition, do not lean on rack-mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). Stability hazard: • The rack may tip over causing serious personal injury. viii Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 9
• Before extending the rack to the installation position, read the installation instructions. • Do not put any load on the slide-rail mounted equipment mounted in the installation position. • Do not leave the slide-rail mounted equipment in the installation position. (L002) (L003) Safety notices ix...
Page 10
CAUTION: Hazardous moving parts nearby. (L008) (L018) CAUTION: High levels of acoustical noise are (or could be under certain circumstances) present. Use approved hearing protection and/ or provide mitigation or limit exposure. (L018) (L031) x Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 11
CAUTION: Enclosure Integrity. • Access covers are intended only for occasional removal. • Follow documented procedures when opening during live or temporary service. • When service is complete, promptly reinstall all covers, lids, and/or doors for correct operation. (L031) All lasers are certified in the U.S. to conform to the requirements of DHHS 21 CFR Subchapter J for class 1 laser products.
Page 12
Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
Page 13
Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate.
Page 14
Systems: Installing the IBM Power S1012 (9028-21B)
Page 15
Installing the IBM Power S1012 (9028-21B) Use this information to learn about installing tthe IBM Power S1012 (9028-21B) servers. Installing a rack-based server Use this information to learn about installing a rack-based server. Prerequisite for installing the rack-mounted server Use the information to understand the prerequisites that are required for installing the server.
Page 16
Ensure that you received all the parts that you ordered. Note: Your order information is included with your product. You can also obtain the order information from your marketing representative or the IBM Business Partner. Determining and marking the location in the rack You might need to determine where to install the system unit into the rack.
Page 17
Figure 1. Removing a filler panel 4. Determine to place the system in the rack. Record the EIA location. Note: An EIA unit on your rack consists of a grouping of three holes. Installing the IBM Power S1012 (9028-21B) 3...
Page 18
5. Facing the front of the rack and working from the right side of the rack, use tape, a marker, or pencil to mark the top hole of the highest EIA unit. Next, mark the lowest hole on the EIA unit directly below this EIA unit. 4 Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 19
The following graphic shows the top location that you marked (1) and the lowest location that you marked (2). The rail pins (3) and (4) will extend through the rack flange and, in later steps, you will install a screw into each threaded hole on the rail (5) and (6). Installing the IBM Power S1012 (9028-21B) 5...
Page 20
Do not install mismatched hardware by using washers or spacers. If you do not have the correct rails and fittings for your rack, contact your IBM reseller.If you don’t have the correct rails and fittings for your rack, contact your reseller.
Page 21
Figure 5. Loosening the rails 2. Standing at the front of the rack, align the locating pins on the end of the left rail with the holes that you marked on the rear of the rack. Installing the IBM Power S1012 (9028-21B) 7...
Page 22
Figure 6. Aligning the locating pins with the marked holes at the rear of the rack 3. Push the rail into the rack flange until the pins extend through the rear rack flange holes that you marked. 8 Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 23
4. Extend the front half of the rail toward the front of the rack until the locating pins extend through the front rack flange holes. Note that the uppermost rail pin goes through the hole below the uppermost rack flange hole that you marked. Installing the IBM Power S1012 (9028-21B) 9...
Page 24
Figure 8. Extending the front of the rail toward the front of the rack 5. Tighten the inner rail set screw. 10 Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 25
7. Attach the left rail to the front rack flange by installing one M5x10L screw between each rail locating pin. 8. Attach the right rail to the front rack flange by installing one M5x10L screw between each rail locating pin. Installing the IBM Power S1012 (9028-21B) 11...
Page 26
11. Attach the right rail to the rear of the rack by installing two screws. Install one M5x10L screw into the hole under each of the two locating pins. 12 Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 27
5 seconds. CAUTION: This system requires two people to install the system into the rack. To install the system into the rack, complete the following steps: Installing the IBM Power S1012 (9028-21B) 13...
Page 28
Figure 12. Sliding the system chassis onto the rails 2. Install one M5x10L screw through the second to last hole in the second EIA unit on each side of the system chassis. 14 Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 29
(IPL) completes. b. Plug the system power cords and the power cords for any other attached devices into the power source. c. If your system uses a power distribution unit (PDU), complete the following steps: Installing the IBM Power S1012 (9028-21B) 15...
Page 30
In the navigation area, select Resources > All Systems. b. In the content pane, select the managed system. c. In the navigation area, select System Actions > Operations > Power On. 16 Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 31
This cable (part number 46K5108) is used to convert the ASCII terminal 9-pin Dshell connector to an RJ45 serial port connector on the system. For information about the locations of the connectors on the system, see Part locations and location codes (http://www.ibm.com/support/knowledgecenter/ POWER10/p10ecs/p10ecs_locations.htm).
Page 32
Before you begin To manage POWER10 processor-based systems, the HMC must be at version 10 release 3.0, or later. 18 Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 33
For more information about starting a system or logical partition by using the HMC, see Starting a system or logical partition by using the HMC. 5. To power on a managed system, see Starting a system(http://www.ibm.com/support/ knowledgecenter/POWER10/p10haj/crustartsys.htm) 6. Create partitions using templates.
Page 34
• Install the VIOS operating system. For instructions, see Installing VIOS (https://www.ibm.com/ support/knowledgecenter/POWER10/p10hb1/p10hb1_vios_install.htm). • Install the IBM i operating system. For instructions, see Installing the IBM i operating system (http:// www.ibm.com/support/knowledgecenter/POWER10/p10hdx/p10hdx_ibmi.htm). 8. You have now completed the steps to install your server.
Page 35
• Install the VIOS operating system. For instructions, see Installing VIOS (https://www.ibm.com/ support/knowledgecenter/POWER10/p10hb1/p10hb1_vios_install.htm). • Install the IBM i operating system. For instructions, see Installing the IBM i operating system (http:// www.ibm.com/support/knowledgecenter/POWER10/p10hdx/p10hdx_ibmi.htm). 5. You have now completed the steps to install your server.
Page 36
Ensure that you received all the parts that you ordered. Note: Your order information is included with your product. You can also obtain the order information from your marketing representative or the IBM Business Partner. Cabling the server and setting up a console...
Page 37
Cabling the server and accessing Operations Console You can use Operations Console to manage a server that is running the IBM i operating system even if you do not have logical partitions. Before you begin You can access the Operations Console via a LAN connection to IBM i by using IBM i Access Client Solutions (http://www-01.ibm.com/support/docview.wss?uid=isg3T1026805).
Page 38
Operations Console. The system might take 20 - 30 minutes to complete this action. If A6005008 is displayed on the control panel, this means that no Operations Console is available. This might indicate that the system is not preinstalled with IBM i and you must set the console type to LAN.
Page 39
If none of the indicators are flashing, check the power cord connections. 3. Power on the managed system. Installing the IBM Power S1012 (9028-21B) 25...
Page 40
Compare your installed firmware level with available firmware levels. For more information, see the Fix Central website (http://www.ibm.com/support/fixcentral). d. If necessary, update your managed system firmware levels. Click Firmware > Update system firmware. 26 Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 41
• Install the VIOS operating system. For instructions, see Installing VIOS (https://www.ibm.com/ support/knowledgecenter/POWER10/p10hb1/p10hb1_vios_install.htm). • Install the IBM i operating system. For instructions, see Installing the IBM i operating system (http:// www.ibm.com/support/knowledgecenter/POWER10/p10hdx/p10hdx_ibmi.htm). Completing the server setup without using an HMC If you do not have an Hardware Management Console (HMC), use this procedure to complete the server setup.
Page 42
• Install the VIOS operating system. For instructions, see Installing VIOS (https://www.ibm.com/ support/knowledgecenter/POWER10/p10hb1/p10hb1_vios_install.htm). • Install the IBM i operating system. For instructions, see Installing the IBM i operating system (http:// www.ibm.com/support/knowledgecenter/POWER10/p10hdx/p10hdx_ibmi.htm). Setting up a preinstalled server Learn how to set up a server that arrives preinstalled in a rack.
Page 43
Ensure that you received all the parts that you ordered. Note: Your order information is included with your product. You can also obtain the order information from your marketing representative or the IBM Business Partner. Removing the shipping bracket and connecting power cords and power distribution unit (PDU) for your preinstalled server Before you set up a console, you must remove the shipping bracket and connect power cords.
Page 44
1. Change the managed system passwords by completing the following steps: For more information about setting passwords for the managed system by using the HMC, see Setting passwords for the managed system (http://www.ibm.com/support/knowledgecenter/ POWER10/p10hai/p10hai_setpassword_enh.htm). 30 Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 45
Importing a partition template (http://www.ibm.com/support/knowledgecenter/ POWER10/p10efc/p10efc_import_partition_template.htm). 7. Install an operating system and update the operating system. • Install the AIX operating system. For instructions, see Installing AIX (http://www.ibm.com/support/ knowledgecenter/POWER10/p10hdx/p10hdx_installaix.htm). • Install the Linux operating system. For instructions, see Installing Linux (http://www.ibm.com/ support/knowledgecenter/POWER10/p10hdx/p10hdx_installlinux.htm).
Page 46
• Install the VIOS operating system. For instructions, see Installing VIOS (https://www.ibm.com/ support/knowledgecenter/POWER10/p10hb1/p10hb1_vios_install.htm). • Install the IBM i operating system. For instructions, see Installing the IBM i operating system (http:// www.ibm.com/support/knowledgecenter/POWER10/p10hdx/p10hdx_ibmi.htm). Completing the server setup without using an HMC If you do not have an Hardware Management Console (HMC), use this procedure to complete the server setup.
Page 47
Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
Page 48
This product uses standard navigation keys. Interface information The IBM Power servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
Page 49
Related accessibility information In addition to standard IBM help desk and support websites, IBM has a TTY telephone service for use by deaf or hard of hearing customers to access sales and support services:...
Page 50
Class A Notices The following Class A statements apply to the IBM servers that contain the Power10 processor and its features unless designated as electromagnetic compatibility (EMC) Class B in the feature information. When attaching a monitor to the equipment, you must use the designated monitor cable and any interference suppression devices supplied with the monitor.
Page 51
Tel: 914-499-1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist: IBM Deutschland GmbH Technical Relations Europe, Abteilung M456 IBM-Allee 1, 71139 Ehningen, Germany Tel: +49 (0) 800 225 5426 email: HalloIBM@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 / EN 55032 Klasse A.
Page 52
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors...
Page 53
Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
Page 54
This statement applies to products less than or equal to 20 A per phase. This statement applies to products greater than 20 A, single phase. This statement applies to products greater than 20 A per phase, three-phase. 40 Power Systems: Installing the IBM Power S1012 (9028-21B)
Page 55
Contact for FCC compliance information only: fccinfo@us.ibm.com Terms and conditions Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Notices 41...
Page 56
IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed.