Available languages

TrueSTEAM™
Included In thIs humIdIfIer Box
matérIel comprIs dans l'emBallage
Tools needed to install TruesTeam
Wire cutter/stripper
1-3/4-in. diameter hole saw
1/8-in. drill bit
Standard screwdriver
18-gauge wire (up to 5 conductor)
Torx driver T-20 and T-30
Other Requirements
TrueSTEAM flushes water at or above 140°F (60°C).
Refer to local codes for proper draining practices
for hot water.
Condensate pump rating of 212°F (100°C) if used.
Drip pan with water sensor shut-off required underneath
TrueSTEAM if installed in or above finished space.
Remote installation requires separate purchase of the
Honeywell Remote Mounting Kit (#50024917)
PROFESSIONAL INSTALLATION GUIDE • GUIDE D'INSTALLATION PROFESSIONNELLE
f
J
1
g
h
J
2
TrueSTEAM
Mounting bracket and hardware
Water filter and backflow preventer
Saddle valve
Water supply hose
e
Drain hose (10 feet)
f
Duct nozzle and gasket
g
Owner's manual
h
Service label
I
Prestige HD color
J
1
TrueIAQ
control*
J
2
Humidity
J
3
VisionPRO IAQ
J
4
*
Control based on model ordered.
e
I
J
J
3
4
control*
control*
control*
69-2285EF-01
TM

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell HM512W1005

  • Page 1 Condensate pump rating of 212°F (100°C) if used. Humidity control* Drip pan with water sensor shut-off required underneath VisionPRO IAQ control* TrueSTEAM if installed in or above finished space. Control based on model ordered. Remote installation requires separate purchase of the Honeywell Remote Mounting Kit (#50024917) 69-2285EF-01...
  • Page 2 Contenu de cette boîte A Système TrueSTEAM B Support de montage et visserie C Vanne d’arrêt et dispositif anti-refoulement D Vanne à étrier E Tuyau d’alimentation en eau de 1/4 po F Tuyau de vidange de 1/2 po (3 m/10 pi) G Buse de gaine et joint H Guide du propriétaire Étiquette relative aux...
  • Page 3: Table Of Contents

    NEED HELP? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502. Read and save these instructions. ® U.S. Registered Trademark. Patents pending. Copyright © 2009 Honeywell International Inc. All rights reserved. TrueSTEAM Humidification System 69-2285EF—01...
  • Page 4: Safety Definitions And Precautions

    Safety Definitions and Precautions Safety Definitions These safety terms identify information you must read. CAUTION: Indicates a hazardous situation which, if not avoided, could cause bodily injury or property damage. WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Safety Precautions Make sure you read and understand the following safety hazards before installing, using, or working with the TrueSTEAM humidifier:...
  • Page 5: Setting Homeowner Expectations

    Setting Homeowner Expectations Make sure the homeowners know what to expect from their TrueSTEAM humidifier. Discuss the following points with the homeowners and answer any questions they have. • Achieving Humidity Setpoint. It may take up to a week of continuous operation to achieve the humidity setpoint.
  • Page 6: Important Installation Requirements

    TrueSTEAM and shorten its life. • Do not mount directly to duct board. The remote mount nozzle attachment is allowed only with a Honeywell duct board adapter kit. See “Appendix B: Parts List” on page 35.
  • Page 7: Choosing A Mounting Method

    Choosing a Mounting Method Before installing TrueSTEAM in a home, you must decide which mounting method you want to use: Which is right for you? DUCT MOUNTING – if you can mount REMOTE MOUNTING – if a suitable TrueSTEAM onto the supply duct of mounting location can not be found the HVAC system: on the supply duct:...
  • Page 8: Duct Mounting

    Duct Mounting Before beginning Duct Mounting: I have confirmed local codes for proper draining practices for hot water I have chosen an installation location that meets the requirements on page 4 Follow these steps to mount TrueSTEAM directly to the supply duct of the homeowner’s HVAC equipment. STEP ONE: Select a Mounting Location Choose a location that has access to a cold...
  • Page 9: Step Three: Install Mounting Bracket

    STEP THREE: Install Mounting Bracket to the Duct Position the template on the supply duct: • Make sure the template is level and in the desired position on the duct. • Ensure proper clearances from A-coil. • Make sure the duct nozzle will have proper ”...
  • Page 10: Choosing The Proper Water Filter

    TrueSTEAM water supply. The harder the water, the more dissolved minerals it holds. This leads to faster solid mineral accumulation in the tank. Honeywell provides water filtration solutions that fit the needs of the home’s water hardness. A water hardness test kit is included with TrueSTEAM to assess which filter is needed.
  • Page 11: Step Two: Interpret The Test Result

    If water hardness is in range 1: If water hardness is in range 2: M29661 M29602 Honeywell recommends using the RO Filtration Honeywell recommends using the system (sold separately). polyphosphate filter (sold separately). Note: If the RO Filtration System is not used, set the homeowner’s expectation that additional cleaning beyond once per season will be necessary.
  • Page 12: Water Supply And Water Drain Connections

    Use clamps or ties to secure the water filter in a location that allows for removing and replacing it in the future. Honeywell recommends changing the water filter annually. Install the provided backflow preventer, as required by code.
  • Page 13: Step Three: Connect Truesteam To The Water Pipe

    STEP THREE: Connect TrueSTEAM to the Water Pipe Connect one end of the remaining length of water line to the backflow preventer. Apply a modest pull to ensure a tight fit. See “Appendix F: Reverse Osmosis Filter” on page 42 if using the Reverse Osmosis Filter. Connect the other end of this line to the saddle valve M29606 or T-fitting and manual shutoff valve.
  • Page 14: Before Wiring Truesteam

    Before Wiring TrueSTEAM Before wiring the TrueSTEAM: I will read the section “Using the DIP Switches” beginning on this page I will read the section “Deciding on the Wiring Configuration” beginning on page 14 TrueSTEAM wiring is different from evaporative pad humidifier wiring. In addition to solenoid water valve actuation, TrueSTEAM can monitor system power and regulate system fan operation.
  • Page 15: Step Three: Set The Automatic Flush Cycle Timing

    For water that is filtered through • The home’s water hardness determines how often a softener or filter. the Honeywell RO Filter System. automatic flushing should be performed. • The automatic flush timing can be changed any time after installation by setting the DIP 1 and DIP 2 positions, as shown at left.
  • Page 16: Deciding On The Wiring Configuration

    Deciding on the Wiring Configuration Before making decisions about wiring configurations: I understand when to use the DIP switches and how to set them for the humidity control. You need to decide on the configurations you will use before wiring the TrueSTEAM, These decisions will affect how the connections are made, how the DIP switches are set, and how TrueSTEAM operates for the homeowner.
  • Page 17 WIRING BASICS: CONFIGURATION 1 Note: This image is not a complete wiring diagram. It only depicts power monitoring. When using a thermostat with integrated See “Wiring the TrueSTEAM” on page 19. humidity control (such as VisionPRO IAQ or Prestige): Thermostat with Humidity Control •...
  • Page 18: Step Two: Make System Fan Regulation Decision

    STEP TWO: Make System Fan Regulation Decision System Fan Regulation is a configuration that requires TrueSTEAM to monitor the HVAC system fan and make sure the fan is on if humidity is needed. This helps ensure that airflow will distribute humidity into the living space, and prevents water condensation in the duct.
  • Page 19 WIRING BASICS: CONFIGURATION 1 Note: This image is not a complete wiring diagram. It only depicts fan regulation. See When using a thermostat with integrated “Wiring the TrueSTEAM” on page 19. humidity control (such as VisionPRO IAQ or Prestige): • A thermostat controls the fan and Thermostat with Humidity Control...
  • Page 20: Step Three: Make Add-On Air Proving Decision

    STEP THREE: Make Add-On Air Proving Decision In addition to monitoring system power and fan regulation, TrueSTEAM can monitor physical air movement through an optional add-on air proving device. If an air proving device is added, TrueSTEAM can create steam only if the fan is moving air through the supply duct.
  • Page 21: Wiring The Truesteam

    Wiring the TrueSTEAM You will need to wire TrueSTEAM using the diagram that applies to your humidity control. Remember to include the wiring and DIP settings required for power monitoring, system fan regulation, and add-on air proving (if used). Using the Terminals Use the terminals (found inside the cover) to wire TrueSTEAM to the humidity control and the HVAC system.
  • Page 22: Using The Correct Control Diagram

    OPTION 1: Dry-contact Mechanical Humidistat Wiring Thermostat Make sure that the thermostat used isolates Y from G. All Honeywell Prestige, VisionPRO IAQ, VisionPRO, and Focus Pro TrueSTEAM thermostats do this. H8908...
  • Page 23 OPTION 3: VisionPRO IAQ Wiring with Humidity Control Fan Delay • Follow this diagram if you are using VisionPRO IAQ with TrueSTEAM’s fan-delay feature. • The system fan will turn on when the water temperature reaches 176°F (80°C). TrueSTEAM HVAC System Set installer setup #0374 to 3.
  • Page 24 OPTION 5: RedLINK Prestige HD Humidity Control TrueSTEAM Connection (Wireless) “1” in Prestige Installer setup, program HVAC System humidity calls to “Humidify Forces Fan On.” M29626 TrueSTEAM Humidification System 69-2285EF—01...
  • Page 25: Startup And Checkout

    Startup and Checkout When installation is complete, plug TrueSTEAM in and turn the humidity control on. Make sure it is running properly before turning the system over to the homeowner. Once TrueSTEAM is running, day-to-day operation is hands-free, except for occasional cleaning. The homeowner can use the control to adjust the humidity setpoint, adjust the frost setting (if used), or turn TrueSTEAM off as desired.
  • Page 26: Routine Maintenance

    At the end of the cycle, TrueSTEAM refills the tank with fresh water and automatically returns to normal operation. Manual Cleaning Cycle Honeywell recommends that TrueSTEAM be manually cleaned and the water filter be changed at least once each humidification season. The manual cleaning is necessary to remove solid mineral deposits left behind during operation.
  • Page 27 CAUTION: Scalding hazard. • If you override the cooling action of the flush cycle, the tank will empty immediately, regardless of water temperature. Make sure the drain can handle up to 212°F (100°C) if you do this. • During manual drain, initial water temperature may be above 140°F (60°C). Scalding water could splash out of the drain.
  • Page 28: Step Two: Remove The Water Tank

    STEP TWO: Remove the Water Tank Make sure the tank is empty. The Empty light turns on when it is. Turn the manual shutoff valve to the “Unlock” position. Grip the white water valve arm and slide it back to disengage from the tank’s black spool.
  • Page 29: Step Three: Clean The Tank

    STEP THREE: Clean the Tank Use tap water to flush loose minerals from the tank: • Sediment screen at tank’s bottom is removable. • For a more thorough cleaning, soak tank in water with CLR , LimeAway or white vinegar. Then ®...
  • Page 30: Step Five: Reinstall The Tank

    STEP FIVE: Reinstall the Tank Before reinstalling the tank and cover, perform these checks: • Clear any dust from the ventilation holes in the cover. • Clear any debris from the water drain tube. • Make sure the water tank gasket seal is seated properly in the TrueSTEAM base.
  • Page 31: Changing The Water Filter

    Changing the Water Filter Replace the polyphosphate water filter (provided with TrueSTEAM) at least once every humidification season. Turn the water supply off at the saddle valve or T-fitting and manual shutoff valve. Press down on the filter collar ring and pull out the 1/4-inch water line from each side of the filter.
  • Page 32: Troubleshooting

    Troubleshooting TrueSTEAM has internal system diagnostics that monitor operation, maintenance schedules, and faults. If a system fault is detected, TrueSTEAM will attempt to recover up to five times in a 24-hour period. • If TrueSTEAM is unable to recover by itself within 24 hours, the red Service light blinks in a series that indicates the fault detected.
  • Page 33 No. of Fault Description Auto-Recoverable? Steps to Fix Service LED (Performed Only By Professional HVAC Technician) Blinks Heating element Follow the tank cleaning steps. See “Manual Cleaning Cycle” overheated. on page 24. Reassemble tank and press the Go button to reset. If the fault returns, replace TrueSTEAM.
  • Page 34 No. of Fault Description Auto-Recoverable? Steps to Fix Service LED (Performed Only By Professional HVAC Technician) Blinks The heater relay Press and hold the Go button to clear the fault. failed to turn on. Initiate a humidity call. If the fault returns, replace TrueSTEAM. Temperature of the Yes, system will Make sure ventilation holes in the cover are clear of...
  • Page 35 No. of Fault Description Auto-Recoverable? Steps to Fix Service LED (Performed Only By Professional HVAC Technician) Blinks Power to the wireless Yes, system will Verify wiring between TrueSTEAM and the wireless adapter. adapter overloaded. return to “Ready” Ensure DIP switches are set correctly. (DIP 3 up. Also DIP 4 up if fault no longer if TrueSTEAM R and C aren’t wired.) exists in one hour.
  • Page 36: A: Specifications

    A: Specifications Humidifying Capacity Electrical Ratings and Tolerances HM506: up to 6 gallons per day (gpd) Input Ratings (23 liters per day [lpd]) • Power Supply: 120VAC +10-15%, 60Hz HM509: up to 9 gpd (34 lpd) - HM506: 840W at 120VAC at full load HM512: up to 12 gpd (45 lpd) - HM509: 1200W at 120VAC at full load - HM512: 1440W at 120VAC at full load...
  • Page 37: B: Parts List

    B: Parts List Figure Part Number Part Description Reference 50024917-001 Remote Mounting Kit (with 10-foot hose) 50024917-002 Remote Mounting Kit (with 20-foot hose) 50028004-001 Cover 50028003-001 Duct Nozzle 50028001-001 Remote Nozzles 50020012-001 Mounting Bracket 50027997-001 Solenoid Valve 50028044-001 Polyphosphate Filter 50033181-001 HM512/HM509 Water Tank 50033182-001...
  • Page 38: C: Remote Installation

    Use provided anchors if mounting to drywall or plaster TrueSTEAM If humidifier is in finished space, always TERMINAL install a drip pan with wet switch. Honeywell recommends Diversitech WS-1 (wiring shown here.) BLACK GREEN ORANGE M28708 TrueSTEAM Humidification System 69-2285EF—01...
  • Page 39 Cut a slit in the insulation half way around the hose. Do not cut into the Insert the hose clamp into rubber steam hose. the slit and hook it onto the rubber hose. 3 inches minimum clearance from nozzle outlet to duct. Nozzle at upward pitch.
  • Page 40: D: Advanced Wiring

    D: Advanced Wiring TrueSTEAM Wired to a Dedicated Fan/Blower TrueSTEAM nozzle must be inserted into TrueSTEAM Gen Purpose a dedicated duct box. Do not leave TrueIAQ SPST Relay Fan/Blower #R8222 nozzle exposed. min 250 CFM Optional Air 120 VAC Proving Switch •...
  • Page 41 TrueSTEAM Wired to a Thermostat in a Zoned Application If air proving switch is used, set TrueSTEAM TrueSTEAM DIP 4 down and DIP 5 up. Optional Air Proving Switch Connect the thermostats, dampers, transformers, and sensor wires as shown in the Truezone HZ432 panel instructions. Zone 1 In VisionPRO IAQ installer setup, set ISU VisionPro IAQ...
  • Page 42 Wiring Multiple TrueSTEAMs to One Humidity Control Ensure thermostat isolates Y from G. Conventional Thermostat All Honeywell Prestige, VisionPRO, and FocusPro thermostats do this. TrueSTEAM TrueSTEAM Separate Humidity Control M29641 TrueSTEAM Humidification System 69-2285EF—01...
  • Page 43 TrueSTEAM Humidification System 69-2285EF—01...
  • Page 44: F: Reverse Osmosis Filter

    F: Reverse Osmosis Filter If the TrueSTEAM owner’s home has hard water, the Honeywell Reverse Osmosis (RO) Filtration System (#50045947) should be installed in the water supply line. The RO Filtration System consists of a base chassis, with three filter cylinders: •...
  • Page 45: Setting Up The Ro Filter

    Setting up the RO Filter See the instruction sheet packaged with the RO Filtration System for complete installation instructions. 1. Mount the base chassis to a surface capable of holding up to 7 pounds between the home’s cold water line and the TrueSTEAM location. (Mounting hardware is provided.) t e r 2.
  • Page 46: Maintaining The Ro Filter

    Maintaining the RO Filter Honeywell recommends the following maintenance steps be performed at least once each humidification season. Remove filters #1, #2, and #3, in this order. Reconnect filters in this order: • Empty water from the #3 filter and reconnect to the RO System.
  • Page 47 Services à la clientèle de Honeywell au 1-800-468-1502. Veuillez lire et conserver ces instructions. ® Marque de commerce déposée aux États-Unis. Brevets en instance. Copyright © 2009 Honeywell International Inc. Tous droits réservés. Système d’humidification TrueSTEAM 69-2285EF—01...
  • Page 48: Définitions Relatives À La Sécurité Et Précautions

    Définitions relatives à la sécurité et précautions Définitions relatives à la sécurité L’information portant sur l’identification des termes de sécurité doit être lue. MISE EN GARDE : Indique une situation dangereuse qui, si elle n’est pas évitée, risque d’endommager le produit ou de causer des blessures corporelles.
  • Page 49: Détermination Des Attentes Des Clients

    Détermination des attentes des clients Assurez-vous que les propriétaires savent à quoi s’attendre de leur humidificateur TrueSTEAM. Discutez des points suivants avec les propriétaires et répondez à d’éventuelles questions de leur part. • Établissement du point de consigne d’humidité. Il peut s’écouler jusqu’à une semaine avant que le point de consigne d’humidité...
  • Page 50: Exigences D'installation Importantes

    Exigences d’installation importantes Le non-respect de ces exigences annulera la garantie, nuira à l’installation et entraînera des appels de service injustifiés. Sécurité personnelle • Portez des lunettes de protection lors de l’installation du système TrueSTEAM. • Assurez-vous de ne pas entailler la canalisation électrique ou de refroidissement de l’air. •...
  • Page 51: Choix D'une Méthode De Montage

    Choix d’une méthode de montage Avant d’installer un système TrueSTEAM dans un domicile, vous devez opter pour une méthode de montage : Quelle est celle qui vous convient? MONTAGE EN GAINE – Si vous pouvez MONTAGE À DISTANCE – S’il est impossible monter le système TrueSTEAM sur la gaine de trouver un emplacement de montage d’alimentation du système CVCA :...
  • Page 52: Montage En Gaine

    Montage en gaine Avant de commencer le montage en gaine : J’ai consulté les codes locaux portant sur les pratiques de vidange adéquates pour l’eau chaude J’ai choisi un emplacement d’installation qui répond aux exigences de la page 4 Suivez ces étapes pour monter le système TrueSTEAM directement sur la gaine d’alimentation de l’équipement CVCA du propriétaire.
  • Page 53: Truesteam Sur Le Support De Montage

    ÉTAPE TROIS : Installation du support de montage dans la gaine Placez le gabarit sur la gaine d’alimentation : • Assurez-vous que le gabarit est de niveau et dans la position désirée sur la gaine. • Respectez les dégagements appropriés de la bobine en A.
  • Page 54: Choix Du Bon Filtre À Eau

    Cela entraîne une accumulation plus rapide de minéraux solides dans le réservoir. Honeywell fournit des solutions de filtration de l’eau qui répondent aux exigences de la dureté de l’eau domestique. Un nécessaire de mesure de la dureté de l’eau qui permet de déterminer le filtre à utiliser accompagne le système TrueSTEAM.
  • Page 55 Si la dureté de l’eau correspond à la plage 2 : M29661 M29602 Honeywell recommande d’utiliser le système de filtration OI (vendu séparément). Honeywell recommande d’utiliser le filtre en Remarque : Si le système de filtration OI n’est pas utilisé, informez polyphosphate (vendu séparément).
  • Page 56: Raccords De L'alimentation Et De La Vidange D'eau

    Utilisez des colliers de serrage ou des sangles pour fixer le filtre à eau dans un emplacement qui permet sa dépose et son éventuel remplacement. Honeywell recommande de remplacer le filtre à eau sur une base annuelle. Installez le dispositif anti-refoulement fourni, comme le requièrent les codes.
  • Page 57: Étape Trois : Raccord Du Système Truesteam À La Canalisation D'eau

    ÉTAPE TROIS : Raccord du système TrueSTEAM à la canalisation d’eau Raccordez une extrémité de la canalisation d’eau restante au dispositif anti-refoulement. Exercez une légère traction pour assurer un ajustement serré. Consultez l’ « Annexe F : Filtre à osmose inversée » de la page 42 si on utilise un filtre à...
  • Page 58: Avant Le Câblage Du Système Truesteam

    Avant le câblage du système TrueSTEAM Avant le câblage du système TrueSTEAM : J’ai lu la section « Utilisation des commutateurs DIP » commençant sur cette page J’ai lu la section « Choix de la configuration de câblage » commençant à la page 14 Le câblage TrueSTEAM est différent du câblage du tampon humidificateur à...
  • Page 59: Étape Trois : Réglage De La Minuterie Du Cycle De Vidange Automatique

    Pour de l’eau qui est filtrée au moyen basant sur la durée active de chauffage de l’élément. non adoucie, non filtrée. du système de filtration OI de Honeywell. • La dureté de l’eau du domicile influence la fréquence de vidange automatique.
  • Page 60: Choix De La Configuration De Câblage

    Choix de la configuration de câblage Avant de prendre des décisions concernant les configurations de câblage : Je comprends quand utiliser les commutateurs DIP et comment les placer pour réguler l’humidité. Vous devez décider des configurations que vous utiliserez avant de câbler le système TrueSTEAM. Ces décisions auront une incidence sur la réalisation des connexions, le positionnement des commutateurs DIP et le fonctionnement du système TrueSTEAM pour le propriétaire.
  • Page 61 NOTIONS FONDAMENTALES DE CÂBLAGE : Remarque : Cette image ne montre pas un schéma de câblage complet. Elle illustre CONFIGURATION 1 uniquement la surveillance de l’alimentation. Consultez la rubrique « Câblage du système TrueSTEAM » de la page 19. Lors de l’utilisation avec régulateur d’humidité...
  • Page 62: Étape Deux : Choix De La Régulation Du Système De Ventilateur

    ÉTAPE DEUX : Choix de la régulation du système de ventilateur La régulation du ventilateur du système est une configuration qui commande au système TrueSTEAM de surveiller le système CVCA et de s’assurer que le ventilateur fonctionne s’il est nécessaire de produire de l’humidité.
  • Page 63 Remarque : Cette image ne montre pas un schéma de câblage complet. Elle illustre NOTIONS FONDAMENTALES DE CÂBLAGE : uniquement la régulation du ventilateur. Consultez la rubrique « Câblage du système TrueSTEAM » de la page 19. CONFIGURATION 1 Lors d’une utilisation avec régulateur Thermostat avec d’humidité...
  • Page 64: Étape Trois : Choix D'un Appareil Complémentaire De Vérification De La Présence D'air

    ÉTAPE TROIS : Choix d’un appareil complémentaire de vérification de la présence d’air En plus de surveiller l’alimentation du système et la régulation du ventilateur, le système TrueSTEAM peut surveiller le mouvement de l’air physique par l’intermédiaire d’un appareil complémentaire de vérification de la présence d’air.
  • Page 65: Câblage Du Système Truesteam

    Câblage du système TrueSTEAM Vous devrez câbler le système TrueSTEAM en utilisant le schéma qui s’applique à votre régulateur d’humidité. N’oubliez pas d’inclure le câblage et les réglages des commutateurs DIP requis pour la surveillance de l’alimentation, de la régulation du ventilateur du système et la vérification de la présence d’air à l’aide de l’appareil complémentaire (si utilisé).
  • Page 66: Utilisation Du Bon Schéma De Régulation

    OPTION 1 : Câblage de l’humidistat mécanique à contact sec Thermostat Assurez-vous que le thermostat utilisé isole la connexion Y de la connexion G. TrueSTEAM Tous les thermostats Honeywell Prestige, VisionPRO IAQ, VisionPRO et Focus Pro le H8908 font. Système CVCA MF29622 OPTION 2 : Câblage du TrueIAQ...
  • Page 67 OPTION 3 : Câblage du VisionPRO IAQ Régulateur avec délai du ventilateur d’humidité • Suivez le diagramme si vous utilisez le VisionPRO IAQ avec l’option de temporisation du ventilateur du système TrueSTEAM. TrueSTEAM Système CVCA • Le ventilateur du système s’allume lorsque la température de l’eau atteint 80 °C (176 °F).
  • Page 68 OPTION 5 : Connexion RedLINK Prestige Régulateur d’humidité TrueSTEAM HD (sans fil) « 1 » dans la configuration de montage Système CVCA Prestige, programme les demandes de production d’humidité à « L’humidité force la mise en marche du ventilateur ». MF29626 Système d’humidification TrueSTEAM 69-2285EF—01...
  • Page 69: Démarrage Et Vérification

    Démarrage et vérification Une fois l’installation complétée, branchez le système TrueSTEAM et mettez le régulateur d’humidité en fonction. Assurez-vous qu’il fonctionne correctement avant que le propriétaire ne prenne possession du système. Une fois le système TrueSTEAM opérationnel, le fonctionnement journalier ne nécessite aucun entretien, à l’exception d’un nettoyage occasionnel.
  • Page 70: Entretien De Routine

    Cycle de nettoyage manuel Honeywell recommande de nettoyer manuellement le système TrueSTEAM et de remplacer le filtre à eau au moins une fois par saison d’humidification. Le nettoyage manuel est nécessaire pour retirer les dépôts de matières solides résiduelles attribuables au fonctionnement.
  • Page 71 MISE EN GARDE : Risque d’ébouillantement. • Si vous annulez le procédé de refroidissement du cycle de vidange, le réservoir se videra immédiatement peu importe la température de l’eau. Assurez-vous que le drain peut supporter des températures atteignant 100 °C (212 °F) si vous choisissez cette option. •...
  • Page 72: Étape Deux : Dépose Du Réservoir D'eau

    ÉTAPE DEUX : Dépose du réservoir d’eau Assurez-vous que le réservoir est vide. Le voyant Empty (Vide) s’allume lorsqu’il l’est. Tournez la vanne d’arrêt manuelle à la position « Unlock » (Déverrouiller). Saisissez le bras de la vanne d’eau blanche, puis glissez-le vers l’arrière pour le désengager de la bobine noire du réservoir.
  • Page 73: Étape Trois : Nettoyage Du Réservoir

    ÉTAPE TROIS : Nettoyage du réservoir Utilisez de l’eau du robinet pour retirer les minéraux libres du réservoir : • La crépine à sédiments qui se trouve au bas du réservoir est amovible. • Pour un nettoyage plus approfondi, trempez le réservoir dans de l’eau additionnée de CLR , de ®...
  • Page 74: Étape Cinq: Réinstallation Du Réservoir

    ÉTAPE CINQ : Réinstallation du réservoir Avant de réinstaller le réservoir et le couvercle, effectuez les vérifications suivantes : • Enlevez toute la poussière présente dans les orifices de ventilation du couvercle. • Enlevez tout débris présent dans le tube de vidange d’eau.
  • Page 75: Remplacement Du Filtre À Eau

    Remplacement du filtre à eau Remplacez le filtre à eau en polyphosphate (fourni avec le système TrueSTEAM) au moins une fois par saison d’humidification. Coupez l’alimentation en eau à la vanne à étrier ou au raccord en T et à la vanne d’arrêt manuelle. Appuyez sur l’anneau de collier de filtre et tirez la canalisation d’eau de 1/4 po de chaque côté...
  • Page 76: Dépannage

    Dépannage Le système TrueSTEAM dispose d’un dispositif de diagnostic interne qui surveille le fonctionnement, les programmes d’entretien et les anomalies. Si une anomalie système est détectée, le système TrueSTEAM tente de corriger la situation jusqu’à cinq fois dans une période de 24 heures. •...
  • Page 77 Nombre de Description de Auto-récupérable? Étapes de réparation clignotements l’anomalie (réservées à un technicien CVCA professionnel) du voyant de DEL de réparation Surchauffe Suivez les étapes de nettoyage du réservoir. Consultez la rubrique « de l’élément Cycle de nettoyage manuel » de la page 24. chauffant.
  • Page 78 Nombre de Description de Auto-récupérable? Étapes de réparation clignotements l’anomalie (réservées à un technicien CVCA professionnel) du voyant de DEL de réparation L’entrée du Appuyez sur le bouton Go (Aller) et maintenez-le enfoncé pour moniteur soudé supprimer l’anomalie. est active Lancez une demande de production d’humidité.
  • Page 79 Nombre de Description de Auto-récupérable? Étapes de réparation clignotements l’anomalie (réservées à un technicien CVCA professionnel) du voyant de DEL de réparation Aucune Oui, le système Assurez-vous que l’appareil complémentaire de détection de la circulation retournera à présence d’air (facultatif) est installé et correctement câblé. Consultez d’air détectée «...
  • Page 80: A: Spécifications

    A : Spécifications Capacité d’humidification Tensions nominales et tolérances HM506 : Jusqu’à 6 gallons par jour (gpj) Évaluations (23 litres par jour [lpj]) • Alimentation : 120 V c.a. +10-15 %, 60 Hz HM509 : Jusqu’à 9 gpj (34 lpj) - HM506 : 840 W à...
  • Page 81: B: Liste De Pièces

    B : Liste de pièce Référence Numéro de pièce Description de la pièce à la figure 50024917-001 Nécessaire de montage à distance (avec tuyau de 10 pieds) 50024917-002 Nécessaire de montage à distance (avec tuyau de 20 pieds) 50028004-001 Couvercle 50028003-001 Buse de gaine 50028001-001...
  • Page 82: C: Installation À Distance

    Si l’humidificateur se trouve dans un TrueSTEAM endroit fini, installez toujours un plateau BORNE d’écoulement doté d’un commutateur humide. Honeywell recommande d’utiliser le Diversitech WS-1 (câblage illustré ici.) ROUGE NOIR VERT ORANGE MF28708 Système d’humidification TrueSTEAM 69-2285EF—01...
  • Page 83 Percez une fente dans l’isolant en retrait du pourtour du tuyau. Insérez le collier de serrage de Ne coupez pas le tuyau tuyau dans la fente, puis fixez-le de vapeur de caoutchouc. sur le tuyau de caoutchouc. Dégagement minimum de 7,6 cm (3 po) de la prise de buse jusqu’à...
  • Page 84: D: Notions Avancées De Câblage

    D : Notions avancées de câblage Système TrueSTEAM branché à un ventilateur/soufflante dédiés La buse du système TrueSTEAM doit être Relais unipolaire TrueSTEAM unidirectionnel à insérée dans une gaine dédiée. Ne laissez usage général TrueIAQ Ventilateur/soufflante #R8222 pas la buse à découvert. min 250 pi /min Commutateur de...
  • Page 85 Système TrueSTEAM branché à un thermostat dans une application à zonage Si un commutateur de vérification de la TrueSTEAM présence de l’air est utilisé, placez le Commutateur de vérification de la présence d’air (facultatif) commutateur DIP 4 en position basse et le commutateur DIP 5 en position haute (système TrueSTEAM).
  • Page 86 Câblage de plusieurs systèmes TrueSTEAM vers un régulateur d’humidité Assurez-vous que le thermostat isole la Thermostat conventionnel connexion Y de la connexion G. Tous les thermostats Honeywell Prestige, VisionPRO et Focus Pro le font. TrueSTEAM TrueSTEAM Régulateur d’humidité séparé MF29641...
  • Page 87 Système d’humidification TrueSTEAM 69-2285EF—01...
  • Page 88: F: Filtre À Osmose Inversée

    F : Filtre à osmose inversée Si l’eau du domicile du propriétaire du système TrueSTEAM est dure, le système de filtration par osmose inversée de Honeywell (n 50045947) doit être installé sur la canalisation d’alimentation en eau. Le système de filtration OI se compose d’un boîtier de base et de trois cylindres de filtration : •...
  • Page 89 Mise en place du filtre OI Consultez le feuillet d’instructions accompagnant le système de filtration OI pour obtenir de l’information détaillée. 1. Montez le boîtier de base sur une surface en mesure de supporter jusqu’à 7 livres entre la canalisation d’eau froide du domicile et i d e l’emplacement du système TrueSTEAM.
  • Page 90 Entretien du filtre OI Honeywell recommande d’exécuter les étapes d’entretien suivantes au moins une fois par saison d’humidification. Déposez les filtres n 1, 2 et 3 en respectant cette séquence. Rebranchez les filtres en respectant la séquence suivante : • Videz l’eau présente dans le filtre n 3 et rebran- chez au système OI.
  • Page 91 Système d’humidification TrueSTEAM 69-2285EF—01...
  • Page 92 ®U.S. Register Trademark ® Marque déposée aux É.-U. Printed in U.S.A. on recycled Imprimé aux É.-U. sur du papier recyclé © 2009 Honeywell International Inc. paper containing at least 10% contenant au moins 10 % de fibres de 69-2285EF—01 M.S. 11-09 post-consumer paper fibers.