Hardware Installation

Figure 1
6
5
The customer must supply all other cables. For details, refer to
of the Cisco VG30D Voice Gateway User Guide.
Store the packaging material in a clean, dry area for possible re-use.
Hardware Installation
The Cisco VG30D Voice Gateway may be either rack mounted (preferred) or used as a desktop unit.
When you are rack mounting, pay attention to cooling. The Cisco VG30D Voice Gateway has
side-to-side cooling. The design of the rack should allow for adequate airflow for either side of the unit.
Refer to the rack manufacturer's specification for suitable mounting methods.
Ensure the Cisco VG30D Voice Gateway is earthed at all times through the dedicated earth terminal on
Caution
the rear of the unit as shown in
The earthing cable must conform to the following specification.
- Be PVC covered green with yellow longitudinal coloured stripes as defined in EN 60950
- Be rated at 17 amps
- Have a cross sectional area of 1.5mm
- Be of stranded wire 7/0.53, and
- Be terminated with an M3 ring terminal 1-2.6 mm
Figure 2
Cisco VG30D Voice Gateway User Guide
2-2
Package Contents
1
4
Figure
2.
2
Earth Screw on Rear Panel
Earthing
Connection
DISCONNECT MAINS SUPPLY BEFORE REMOVING LID
110 -230 VAC
60 - 50Hz
380mA
FUSE
T2A H 250V
Cisco VG30 D
2
3
Appendix C, "Connectors and Cabling"
It shall:
conductor
2
NO USER SERVICEABLE PARTS
Ethernet
10/100 Base-T
Chapter 2
Installation
OL-19276-01